Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 36269-2018 PDF English

US$150.00 · In stock · Download in 9 seconds
GB/T 36269-2018: Determination of trace nickel for plate glass
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 36269-2018150 Add to Cart Auto, 9 seconds. Determination of trace nickel for plate glass Valid

Similar standards

GB/T 36267   GB/T 36400   GB/T 36268   

GB/T 36269-2018: Determination of trace nickel for plate glass

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT36269-2018
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 81.040.10 Q 33 Determination of trace nickel for plate glass Issued on: JUNE 7, 2018 Implemented on: MAY 1, 2019 Issued by. State Administration for Market Regulation of the People's Republic of China; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Statistical classification ... 4 4 Statistical period ... 5 5 Technical requirements for energy consumption statistics ... 6 6 Method for energy consumption statistics ... 6 7 Energy consumption calculation method ... 12 Determination of trace nickel for plate glass WARNING – Persons using this Standard should be familiar with normal laboratory practice. This Standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.

1 Scope

This Standard specifies the apparatus, general rules, sample preparation, determination method, result expression, accuracy requirements and test report for the determination of trace nickel in plate glass. This Standard applies to the chemical composition analysis of trace nickel in glass substrate, as well as the appraisal analysis of nickel sulfide in glass.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition dated applies to this document. For undated references, the latest edition of the referenced documents (including all amendments) applies to this document. GB/T 6682, Water for analytical laboratory use – Specification and test methods GB/T 8170, Rules of rounding off for numerical values and expression and judgement of limiting values GB/T 9721, Chemical reagent – General rules for the molecular absorption spectrophotometry (ultraviolet and visible) GB/T 12806, Laboratory glassware – One-mark volumetric flasks GB/T 12808, Laboratory glassware – One-mark pipettes GB/T 15337, General rules for atomic absorption spectrometric analysis 3 Apparatus 3.1 Balance mL volumetric flask; cool to room temperature; use water to dilute to scale; shake up. Or use a nationally recognized nickel standard solution. 6.1.2.14 Nickel standard working solution (5 μg/mL) Absorb 25 mL of nickel standard stock solution (6.1.2.13) to pour into a 500 mL volumetric flask; use water to dilute to scale; shake up. 6.1.3 Plotting of standard curve Accurately absorb 0.00 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL of nickel standard working solution (6.1.2.14) to pour into a group of 100 mL volumetric flasks; add water respectively to 30 mL ~ 40 mL; add in succession 5 mL of ammonium citrate aqueous solution (6.1.2.9), 2.5 mL of iodine solution (6.1.2.10), 10 mL of dimethylglyoxime solution (6.1.2.11), 5 mL of ethylenediaminetetraacetic acid disodium salt solution (6.1.2.12). After a solution is added to each flask, shake up. Finally, use water to dilute to scale; shake up and make the standard solution series containing nickel 0.00 μg, 5.00 μg, 10.00 μg, 15.00 μg, 20.00 μg and 25.00 μg. After 5 min, on the spectrophotometer, at 530 nm of wavelength, use the blank reagent as the reference, use a 3 cm cuvette to measure the absorbance of the solutions, and plot the standard curve of absorbance corresponding to the content of nickel in the nickel standard solutions. The testing shall be finished within 30 min. 6.1.4 Analytical procedures 6.1.4.1 Accurately weigh 0.1 g ~ 0.5 g (accurate to 0.1 mg) of sample (5.2) to place into a platinum evaporating dish; use a small amount of water for wetting; add 10 mL of hydrofluoric acid (6.1.2.1) and 0.5 mL of perchloric acid (6.1.2.2); evaporate on a low-temperature electric furnace until white smoke comes out from perchloric acid. Take down to cool; add another 5 mL of hydrofluoric acid (6.1.2.1); continue to evaporate on the low-temperature electric furnace until dry. Take down to cool. Add 5 mL of hydrochloric acid solution (6.1.2.6) and an appropriate amount of water; leach on the low-temperature electric furnace until the solution clarifies; transfer to a 100 mL volumetric flask; control the volume of the solution at about 40 mL. Add 5 mL of ammonium citrate aqueous solution (6.1.2.9); use ammonium hydroxide solution (6.1.2.7) and hydrochloric acid solution (6.1.2.6) to adjust the pH of the solution to neutral; add in succession 2.5 mL of iodine solution (6.1.2.10), 10 mL of dimethylglyoxime solution (6.1.2.11) and 5 mL of ethylenediaminetetraacetic acid disodium salt solution (6.1.2.12). After a solution is added to each flask, shake up. Finally, use water to dilute to scale; shake up. After 5 min, on the spectrophotometer, at 530 nm of wavelength, use the blank reagent as the reference and use a 3 cm cuvette to measure the absorbance of the solutions. The testing shall be finished within 30 min. 6.1.4.2 Blank test Density about 1.68 g/mL; mass fraction 70% ~ 72%; guaranteed reagent. 6.2.2.3 Nitric acid Density about 1.42 g/mL; mass fraction 65% ~ 68%; guaranteed reagent. 6.2.2.4 Absolute ethyl alcohol Density about 0.789 g/mL; mass fraction 99%. 6.2.2.5 Nitric acid solution (1 + 1) 6.2.2.6 Nitric acid solution (1 + 4) 6.2.2.7 Nitric acid solution (1 + 99) 6.2.2.8 Nickel standard stock solution (containing 100 μg/mL of Ni) Accurately weigh 0.100 0 g of high-purity metal nickel (of mass fraction above 99.9%. before weighing, use diluted nitric acid to scour off the oxides on the surface; then use water and absolute ethyl alcohol to wash completely; dry in the air) to place in a beaker; add 20 mL of nitric acid solution (6.2.2.5); after heating to dissolve, transfer to a 1,000 mL volumetric flask; cool to room temperature; use water to dilute to scale; shake up. Or use a nationally recognized nickel standard solution. 6.2.2.9 Nickel standard working solution (5 μg/mL) Absorb 25.00 mL of nickel standard stock solution (6.2.2.8) to pour into a 500 mL volumetric flask; use water to dilute to scale; shake up. 6.2.3 Plotting of standard curve Accurately absorb 0.00 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL of nickel standard working solution (6.2.2.9) to pour into a group of 100 mL volumetric flasks; add in succession nitric acid solution (6.2.2.7) to dilute to scale; shake up. Make the standard solution series containing nickel 0.00 μg, 5.00 μg, 10.00 μg, 15.00 μg, 20.00 μg and 25.00 μg. As shown in Table 1, set the working parameters of the atomic absorption spectrophotometer and adjust to the optimum condition. Use the air-acetylene to measure the absorbance of each standard solution at the wavelength of 232.0 nm of the nickel hollow cathode lamp. Plot the standard curve of absorbance corresponding to the content of nickel in the nickel standard solutions. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 36269-2018 be delivered?Answer: The full copy PDF of English version of GB/T 36269-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 36269-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36269-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 36269-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 36269-2018?

A step-by-step guide to download PDF of GB/T 36269-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 36269-2018".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9