Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 21840-2025 (GB/T 21840-2008) PDF English

US$130.00 · In stock · Download in 9 seconds
GB/T 21840-2008: Vulcanizing accelerator TBBS
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 21840: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 21840-2025289 Add to Cart 3 days Vulcanizing accelerator - N-tert-butyl-1, 3-benzothiazole-2-sulfenamide(TBBS) Valid
GB/T 21840-2008130 Add to Cart Auto, 9 seconds. Vulcanizing accelerator TBBS Valid

Similar standards

GB/T 40409   GB/T 8826   GB/T 31332   GB/T 21840   

GB/T 21840-2008: Vulcanizing accelerator TBBS

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT21840-2008
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 83.040.20 G 71 Vulcanizing accelerator TBBS 硫化促进剂 TBBS ISSUED ON: MAY 15, 2008 IMPLEMENTED ON: NOVEMBER 01, 2008 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Requirements ... 5 4 Test methods ... 5 5 Inspection rules ... 11 6 Marks, packaging, transportation and storage ... 12 Vulcanizing accelerator TBBS

1 Scope

This Standard specifies the requirements, test methods, inspection rules, marks, packaging, transportation and storage for N-tert-butyl-2-benzothiazole sulfenamide (vulcanizing accelerator TBBS). This Standard is applicable to vulcanizing accelerator TBBS made by oxidation of tert- butylamine and vulcanizing accelerator MBT. Chemical name: N-tert-butyl-2-benzothiazole sulfenamide Molecular formula: C11H14N2S2 Structural formula: Relative molecular mass: 238.37 (according to the international relative atomic mass in 2005)

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 191, Packaging and storage marks (GB/T 191-2008, ISO 780:1997, MOD) GB/T 601, Chemical reagent -- Preparations of reference titration solutions GB/T 603, Chemical reagent -- Preparations of reagent solutions for use in test methods (GB/T 603-2002, ISO 6353-1:1982, NEQ) The judgment of the test results shall be carried out according to the rounded value comparison method in GB/T 1250. 4.1 Appearance Use visual inspection method to judge. 4.2 Determination of initial melting point Carry out according to the provisions of GB/T 11409.1. The inner diameter of the capillary containing the specimen is 1.2 mm ~ 1.4 mm. The thickness of the glass is 0.2 mm ~ 0.3 mm. Fill the sample 3mm ~ 6mm. When the temperature of the heat transfer fluid is 25°C lower than the predicted melting point, heat up at a rate of 3°C/min. When it rises to 10°C lower than the predicted melting point, attach the capillary containing the sample to the thermometer. Make the center of the sample at the same height as the middle of the mercury bulb of the thermometer. Insert into thermal fluid. Heat up at (1±0.2)°C/min. 4.3 Determination of heating loss Carry out according to the provisions of GB/T 11409.4. The sampling weight is about 2 g (accurate to 0.1 mg). The temperature of the electric constant temperature drying oven is controlled at (70±2)°C. The heating time is 3 h. 4.4 Determination of ash Carry out according to the provisions of GB/T 11409.7. The sampling weight is about 3 g (accurate to 0.1 mg). The temperature of the high temperature furnace is controlled at (750±25)°C. Burning time is 2 h. 4.5 Determination of sieve residue Determine according to the drying method in Chapter 2 of GB/T 11409.5-1989. Test sieve (GB/T 6003.1): φ 200 mm × 50 mm / 150 μm. 4.6 Determination of methanol insoluble 4.6.1 Reagents Methanol [67-56-1]. 4.6.2 Instruments 4.6.2.1 Watch glass: 150 mm in diameter. 4.6.2.2 Beaker: 500 mL. 4.6.2.3 Sand core crucible: G4. 4.6.2.4 Magnetic stirrer. 4.6.2.5 Oven: capable of maintaining the temperature at (70±2)°C. 4.6.2.6 Suction filter bottle: capacity is 500 mL. 4.6.2.7 Wash bottle: capacity is 500 mL. 4.6.3 Analysis steps Weigh about 2.5 g (accurate to 0.1 mg) of the finely ground specimen and place it in a beaker. Use a watch glass to cover the mouth of the beaker. Add 125 mL of methanol. Stir at (25±5)°C for 30 min on a magnetic stirrer. After dissolving, use a sand core crucible with a constant temperature of (70±2)°C to vacuum filter. Use about 25 mL of methanol to wash the beaker three times. After the filtration, use about 25 mL of methanol to wash the sand core crucible twice. After maintaining 2 min, immediately conduct vacuum suction. At this point, the sand core crucible shall have no visible residue. Place the sand core crucible in an oven at (70±2)°C for 1 h to dry. Take it out. Cool to room temperature in a desiccator. Weigh (accurate to 0.1 mg). 4.6.4 Calculation of results Methanol insoluble matter is calculated as mass fraction w1. The value is expressed in %. It is calculated according to formula (1): Where, m2 - the mass value of the empty sand core crucible and methanol insoluble matter, in grams (g); m1 - the value of the mass of the empty sand core crucible, in grams (g); m0 - the numerical value of the mass of the sample, in grams (g). 4.7 Determination of free amine content 4.7.1 Reagents 4.7.1.1 Absolute ethanol [64-17-5]. 4.7.1.2 Hydrochloric acid standard titration solution: c(HCl) = 0.1 mol/L. 4.7.1.3 Sodium hydroxide standard titration solution: c(NaOH) = 0.1 mol/L. 4.7.1.4 Bromophenol blue indicator solution (10 g/L): Dissolve 1 g of bromophenol ratio of dichloromethane to methanol is 60:40). Use acetonitrile + water as mobile phase. A stainless-steel column with C18 filler and a UV detector (280 nm) are used. TBBS in the specimen is separated and determined by reversed-phase high-performance liquid chromatography. 4.8.2 Reagents and solutions 4.8.2.1 Water: grade two water or ultrapure water filtered through a 0.45 μm pore size filter membrane. 4.8.2.2 Acetonitrile [25-05-8]: chromatographically pure. 4.8.2.3 Glacial acetic acid [64-19-7]: chromatographically pure. 4.8.2.4 Dichloromethane [75-09-2]: chromatographically pure. 4.8.2.5 Methanol [67-56-1]: chromatographically pure. 4.8.3 Instruments 4.8.3.1 High performance liquid chromatography. 4.8.3.2 Recorder: chromatographic data processor or chromatographic workstation. 4.8.3.3 Detector: UV detector. 4.8.3.4 Chromatographic column: C18 (ODS) 4.6 mm × 150 mm, 5 μm (particle size); can provide 40,000 theoretical plates per meter (at least 10,000 plates are required for analysis). 4.8.3.5 Microinjector: 50 μL or autosampler. 4.8.3.6 Ultrasonic oscillator. 4.8.4 Operating conditions of HPLC 4.8.4.1 Mobile phase: a mixture of acetonitrile and water (the volume ratio of acetonitrile and water is 75:25), filtered through a filter membrane and degassed. 4.8.4.2 Flow rate: 2.0 mL/min. 4.8.4.3 Column temperature: 26°C (the temperature difference shall not exceed 2°C). 4.8.4.4 Detection wavelength: 280 nm. 4.8.4.5 Injection volume: 20 μL. 4.8.4.6 Retention time: about 4.0 min. The above operating parameters are typical. According to the characteristics of different This product shall be inspected by the quality supervision and inspection department of the manufacturer according to this Standard before leaving the factory. It is attached with a quality certificate in a certain format, which includes: product name, standard number, manufacturer name, registered trademark, batch number, etc. 5.3 Batching rules Take a homogeneous product of equal mass as a batch. 5.4 Sampling Sampling is conducted according to GB/T 6679. The sampling volume shall not be less than 600 g. Divide into two clean, dry ground-mouth bottles (plastic bags). Seal and affix a label, indicating the name of the manufacturer, product name, batch number, sampling date and the name of the sampling person. One bottle (bag) shall be inspected by the inspection department, and the other bottle (bag) shall be kept sealed for 3 months for future reference. 5.5 Reinspection If one of the indicators in the inspection results of the exit-factory items does not meet the requirements of this Standard, it shall be reinspected by sampling from twice the amount of packaging. If there is still one indicator in the reinspection results that does not meet the requirements of this Standard, then this batch of products shall be rejected.

6 Marks, packaging, transportation and storage

6.1 Marks 6.1.1 There shall be a clear and firm mark on each outer package. Its content includes: product name, standard number, manufacturer name, address, contact number, registered trademark, net content, production date, and batch number. 6.1.2 Each packaged product shall be accompanied by a product exit-factory certificate. Its content includes: product name, standard number, batch number, net content, etc. 6.2 Packaging 6.2.1 This product is packed in wood fiber barrels or woven bags lined with plastic film bags. The net weight of each bag (or barrel) is 25 kg or 20 kg. 6.2.2 If other packaging methods are required, it shall be implemented according to the contract. 6.3 Transpiration The product transportation shall comply with GB/T 191. Protect from sunlight and ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3