GB/T 21551.1-2024 PDF EnglishUS$440.00 · In stock · Download in 9 seconds
GB/T 21551.1-2024: Antimicrobial and cleaning function of household and similar electrical appliances - Part 1: General requirement Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 21551.1: Historical versions
Similar standardsGB/T 21551.1-2024: Antimicrobial and cleaning function of household and similar electrical appliances - Part 1: General requirement---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT21551.1-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 97.030 CCS Y 60 Replacing GB 21551.1-2008 Antimicrobial and Cleaning Function of Household and Similar Electrical Appliances - Part 1.General Requirement Issued on. DECEMBER 31, 2024 Implemented on. JANUARY 1, 2027 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 Introduction... 6 1 Scope... 8 2 Normative References... 8 3 Terms and Definitions... 9 4 Technical Requirements... 12 5 Test Methods... 14 6 Marking and Instructions for Use... 21 Appendix A (normative) Test Method for Inhibition Ring... 23 Appendix B (informative) Common Test Methods for the Antimicrobial, Preventing Mildew, Antiallergenic, Antiviral, Microbial Reduction, Dust Mite Reduction, Allergen Reduction, Virus Reduction and Deodorization Functions of Household Appliances 28 Appendix C (normative) Test Method for the Deodorization Function... 30 Bibliography... 341 ScopeThis document specifies the hygiene and safety, and functional requirements for household and similar electrical appliances with the antimicrobial, microbial reduction and cleaning functions, as well as the marking requirements, and describes the corresponding test methods. This document applies to the research, development, production and inspection of household and similar electrical appliances (hereinafter referred to as “household appliances”) with one or multiple functions of antimicrobia, preventing mildew, antiallergen, antivirus, microbial reduction, dust mite reduction, allergen reduction, virus reduction and deodorization, etc. Other electrical appliances may take this as a reference. This document does not apply to. ---Appliances specifically designed for industrial use; ---Appliances intended for use in special environments where corrosive or explosive gases (such as. dust, steam and methane, etc.) are often present.2 Normative ReferencesThe contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 4288-2018 Household and Similar Electrical Washing Machine GB 4789.2 National Food Safety Standard - Microbiological Examination of Food. Aerobic Plate Count GB/T 5296.2 Instructions for Use of Products of Consumer Interest - Part 2.Household and Similar Electrical Appliances GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values GB/T 18204.2 Examination Methods for Public Places - Part 2.Chemical Pollutants GB/T 18801-2022 Air Cleaner GB/T 18883 Standards for Indoor Air Quality GB 19489 Laboratories - General Requirements for Biosafety GB/T 21551.2 Antimicrobial and Cleaning Function of Household and Similar Electrical Appliances - Part 2.Particular Requirements for Material GB 44498 Household and Similar Electrical Appliances - Health Technical Specification HJ 865 Technical Specification for Olfactory Laboratory Construction HJ 1262 Ambient Air and Waste Gas - Determination of Odor - Triangle Odor Bag Method3 Terms and DefinitionsThe following terms and definitions are applicable to this document. 3.1 Antimicrobia 3.1.1 antimicrobia The process of adopting chemical, physical and other methods to kill bacteria, fungi and other microorganisms, or hinder their growth and reproduction, and make them inactive. [source. WS/T 466-2014, 3.14, modified]. 3.1.2 antimicrobial materials Materials that have the functions of killing bacteria, fungi and other microorganisms, or hindering their growth and reproduction, and making them inactive. 3.1.3 antimicrobial rate In the antimicrobia (3.1.1) test, the reduction in the count of bacteria, fungi and other microorganisms, which is expressed as a percentage. 3.1.4 inhibition ring The antimicrobial agent in the material is continuously dissolved and diffused through agar to form different gradients, thereby inhibiting the growth of bacteria around it and forming a transparent circle. 3.1.5 preventing mildew The process of adopting chemical, physical and other methods to kill mold or hinder its growth and reproduction and make it inactive.4 Technical Requirements4.1 Hygiene and Safety Requirements 4.1.1 Hygiene and safety requirements for the whole machine Household appliances that are explicitly stated to have the functions, such as. microbial reduction and cleaning, have executable product-related standards, and the hygiene and safety of the whole machine shall comply with the standards implemented by the product. If there is no executable product-related standard, except for the special use conditions specified by the appliance, the hazardous substances that may be produced shall all comply with the requirements of Table 1. 4.1.2 Hygiene and safety requirements for components and parts For materials that are explicitly stated to have the antimicrobial function and are in contact with food or in close contact with the human body during use, the diameter of the inhibition ring shall not be greater than 10 mm (including the diameter of the sample piece). 4.2 Requirements for Antimicrobial, Microbial Reduction and Cleaning Functions 4.2.1 Functional requirements for materials and components and parts For materials that are explicitly stated to have the antimicrobial, preventing mildew, antiallergenic and antiviral functions, or components and parts made of antimicrobial materials, preventing mildew materials, antiallergenic materials and antiviral materials, the antimicrobial rate, preventing mildew level, antiallergenic rate and antiviral rate shall comply with the special requirements for materials and components and parts in GB/T 21551.2. 4.2.2 Functional requirements for the whole machine 4.2.2.1 Requirements for microbial reduction function For household appliances that are explicitly stated to have the microbial reduction function, the microbial reduction rate shall not be lower than 70%. 4.2.2.2 Requirements for dust mite reduction function For household appliances that are explicitly stated to have the dust mite reduction function, the dust mite reduction rate shall not be lower than 80%.5 Test Methods5.1 Safety Tips Microbiological laboratories shall comply with relevant provisions of biosafety standards and domestic regulations. The laboratories shall comply with the corresponding biosafety level requirements in GB 19489.The laboratories shall have a biosafety protection level that is compatible with the hazards; 5.2 Hygiene and Safety Tests 5.2.1 Hygiene and safety tests of the whole machine 5.2.1.1 Requirements for sampling points If there are executable product-related standards for household appliances that are explicitly stated to have the microbial reduction and cleaning functions, the hygiene and safety-related tests shall be carried out in accordance with the methods described in the product standards. If there are no executable product-related standards for household appliances that are explicitly stated to have the microbial reduction and cleaning functions, the harmful substances they produce shall be tested in accordance with the following method. 5.2.1.2 General measurement instruments General measurement instruments for the test shall satisfy the following requirements. 5.2.1.3 Ozone leakage The ozone leakage is tested in accordance with the following steps. 5.2.1.4 UV leakage The UV leakage is tested in accordance with the following steps. 5.2.2 Hygiene and safety tests of components and parts For materials that are explicitly stated to have the antimicrobial function, the inhibition ring shall be tested in accordance with the test method described in Appendix A. For materials that are explicitly stated to have the antimicrobial function or components and parts containing antimicrobial materials, the toxicology test shall be carried out in accordance with the test methods described in the relevant standards. 5.3 Antimicrobia, Microbial Reduction and Cleaning Tests 5.3.1 Test of materials and components and parts For materials that are explicitly stated to have the antimicrobial, preventing mildew, antiallergenic and antiviral functions, or components and parts made of antimicrobial materials, preventing mildew materials, antiallergenic materials and antiviral materials, their antimicrobial rate, preventing mildew level, antiallergenic rate and antiviral rate shall be tested in accordance with the methods described in GB/T 21551.2. 5.3.2 Test methods for the whole machine 5.3.2.1 Test of microbial reduction function Household appliances that are explicitly stated to have the microbial reduction function shall be tested in accordance with the product standards they implement. Common microbial reduction methods specified in the promulgated national and industry standards are shown in Appendix B. 5.3.2.2 Test of dust mite reduction function Household appliances that are explicitly stated to have the dust mite reduction function shall be tested in accordance with the product standards they implement. Common dust mite reduction methods specified in the promulgated national and industry standards are shown in Appendix B. For household appliances that are explicitly stated to have the dust mite reduction function, if there are no executable product-related standards, then, based on the use requirements of the appliance, select the appropriate target for testing. 5.3.2.3 Test of allergen reduction function Household appliances that are explicitly stated to have the allergen reduction function shall be tested in accordance with the product standards they implement. Common allergen reduction methods specified in the promulgated national standards and industry standards are shown in Appendix B. For household appliances that are clearly stated to have the allergen reduction function, if there are no executable product-related standards, based on the use requirements of the appliance and in accordance with the requirements of Table 4, select the appropriate target for the allergen to be tested to conduct the test. 5.3.2.4 Test of virus reduction function Household appliances that are explicitly stated to have the virus reduction function shall be tested in accordance with the product standards they implement. Common virus reduction methods specified in the promulgated national and industry standards are shown in Appendix B. For household appliances that are explicitly stated to have the virus reduction function, if there are no executable product-related standards, then, based on the use requirements of the appliance and in accordance with the requirements in Table 6, select the appropriate target for the test virus to conduct the test. 5.3.2.5 Test of deodorization function Household appliances that are explicitly stated to have the deodorization function shall be tested in accordance with the product standards they implement. Common deodorization methods specified in the promulgated national standards and industry standards are shown in Appendix B. For household appliances that are explicitly stated to have the deodorization function, if there are no executable product-related standards, the olfactory identification method or the odor gas removal method may be used for testing.6 Marking and Instructions for Use6.1 Principle The marking and instructions for use of household appliances that are explicitly stated to have the antimicrobial, microbial reduction and cleaning functions should reflect the true attributes of the products, be simple and easy to understand, accurate, scientific, and in line with consumer habits. They shall not contain explicit or implicit indications that may mislead consumers, and shall not use false or exaggerated words. 6.2 Basic Requirements For household appliances that are explicitly stated to have the antimicrobial, microbial reduction and cleaning functions, the marking shall comply with the requirements of GB/T 5296.2. 6.3 Content The instructions for use or product identifications of household appliances that are explicitly stated to have the antimicrobial, microbial reduction and cleaning functions shall include the following contents. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 21551.1-2024 be delivered?Answer: The full copy PDF of English version of GB/T 21551.1-2024 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 21551.1-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21551.1-2024_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 21551.1-2024 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 21551.1-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 21551.1-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 21551.1-2024?A step-by-step guide to download PDF of GB/T 21551.1-2024_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 21551.1-2024". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |