Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 9706.15-2008 PDF English

US$145.00 · In stock · Download in 9 seconds
GB 9706.15-2008: Medical electrical equipment -- Part 1: General requirements for safety. 1 -- Collateral standard: Safety requirements for medical electrical systems
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete

GB 9706.15: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB 9706.15-2008145 Add to Cart Auto, 9 seconds. Medical electrical equipment -- Part 1: General requirements for safety. 1 -- Collateral standard: Safety requirements for medical electrical systems Obsolete
GB 9706.15-1999959 Add to Cart 4 days Medical electrical equipment Part 1: General requiements for safety 1. Collateral standard: Safety requirements for medical electrical systems Obsolete

Similar standards

GB 16174.1   GB 9706.290   GB 9706.1   GB 9706.255   

GB 9706.15-2008: Medical electrical equipment -- Part 1: General requirements for safety. 1 -- Collateral standard: Safety requirements for medical electrical systems


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB9706.15-2008
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040 C 30 GB 9706.15-2008 / IEC 60601-1-1.2000 Replacing GB 9706.15-1999 Medical electrical equipment - Part 1.General requirements for safety - 1.Collateral standard. Safety requirements for medical electrical systems (IEC 60601-1-1.2000, IDT) Issued on. DECEMBER 15, 2008 Implemented on. FEBRUARY 01, 2010 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the PRC; Standardization Administration of the PRC.

Table of Contents

Foreword... 5 SECTION ONE - GENERAL... 7 1 Scope and object... 7 2 Terminology and definitions... 7 3 General requirements... 8 6 Identification, marking and documents... 10 SECTION TWO - ENVIRONMENTAL CONDITIONS... 11 10 Environmental conditions... 11 SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS ... 12 16 ENCLOSURES and PROTECTIVE COVERS... 12 17 Separation... 12 19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS ... 13 SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS... 14 22 Moving parts... 14 SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION... 14 SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES... 14 SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS... 15 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization, disinfection and compatibility... 15 49 Interruption of the power supply... 15 SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT... 15 SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS... 15 52 Abnormal operation and fault conditions... 15 SECTION TEN - CONSTRUCTIONAL REQUIREMENTS... 16 56 Components and general assembly... 16 57 MAINS PARTS, components and layout... 16 58 Protective earthing - Terminals and connection... 17 59 Construction and layout... 18 Annex AAA (informative) General guidance and rationale... 19 Annex BBB (informative) Examples of combinations of MEDICAL ELECTRICAL EQUIPMENT and non-medical electrical equipment... 26 Annex CCC (normative) Normative references... 30 Annex DDD (informative) Bibliography... 31 Annex EEE (normative) Requirements for MULTIPLE PORTABLE SOCKET- OUTLETS... 32 Annex FFF (informative) Examples of application of MULTIPLE PORTABLE SOCKET-OUTLETS... 35 Figure 201 -- Example of PATIENT ENVIRONMENT... 18

Foreword

The full technical content of this Part of GB 9706 is mandatory. “Medical electrical equipment” safety series standard consists of two parts. - Part 1.General requirements for safety; - Part 2.Particular requirements for safety. Part 1 includes, in addition to this Part, other standards. - GB 9706.1 Medical electrical equipment - Part 1.General requirements for safety; - YY 0505 Medical electrical equipment - Part 1-2.General requirements for safety - Collateral standard. Electromagnetic compatibility - Requirements and tests; - GB 9706.12 Medical electrical equipment - Part 1.General requirements for safety - 3.Collateral standard. General requirements for radiation protection in diagnostic X-ray equipment; This Part is Part 15. This Part equivalently adopts IEC 60601-1-1.2000 “Medical electrical equipment - Part 1-1.General requirements for safety - Collateral standard. Safety requirements for medical electrical systems”. The main difference between this Part and IEC 60601-1-1 is that if the international standards referenced in the standard have been converted into Chinese standards, then this Part replaces the referenced international standard number with the corresponding Chinese standard number. This Part replaces GB 9706.15-1999 “Medical electrical equipment - Part 1. General requirements for safety - 1.Collateral standard. Safety requirements for medical electrical systems”. As compared with GB 9706.15-1999, the main changes in this Part are as follows. - The terms and definitions have been adjusted accordingly; - ADD some requirements for accompanying documents of a system (6.8.201); - The contents of continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS (Clause 19) have been adjusted accordingly; - ADD some requirements for connections (56.3.201); - Delete some requirements for protection of wiring (59.201); - The contents of Annex BBB have been adjusted. Annexes CCC and EEE of this Part are normative annexes. Annexes AAA, BBB, DDD, and FFF are informative annexes. This Part was proposed by China Food and Drug Administration. This Part shall be under the jurisdiction of National Technical Committee 10 on Medical Electrical Equipment of Standardization Administration of China (SAC/TC 10). This Part was drafted by Shanghai Testing and Inspection Institute for Medical Devices. Main drafters of this Part. He Jun, Huang Jiahua, Lu E. The previous edition replaced by this Part is as follows. - GB 9706.15-1999. Medical electrical equipment Part 1.General requirements for safety - 1.Collateral standard. Safety requirements for medical electrical systems SECTION ONE - GENERAL

1 Scope and object

This Part applies to the safety of MEDICAL ELECTRICAL SYSTEMS, as defined in 2.201.It describes the safety requirements necessary to provide protection for the PATIENT, the OPERATOR and surroundings.

2 Terminology and definitions

In this Collateral Standard, terms printed in small capitals are used in accordance with their definitions in GB 9706.1. Connection, electrical or otherwise, including those intended to transfer signals and/or power and/or substances.

3 General requirements

MEDICAL ELECTRICAL EQUIPMENT shall comply with the requirements of GB 9706.1 and its relevant particular standards. Compliance is checked by inspection of appropriate documents or certificates. After installation or subsequent modification, the SYSTEM shall be in compliance with the requirements of this Collateral Standard.

6 Identification, marking and documents

A SYSTEM (including a modified SYSTEM) shall be accompanied by documents containing all the data necessary for safe and intended use. These documents shall include.

10 Environmental conditions

A power supply from another equipment for EQUIPMENT in a SYSTEM shall be specified by the manufacturer.

16 ENCLOSURES and PROTECTIVE COVERS

Parts of non-medical electrical equipment in the PATIENT ENVIRONMENT that, after removal of covers, connectors, etc., without the use of a TOOL, may be contacted by the OPERATOR during routine maintenance, calibration, etc., shall operate at a voltage not exceeding 25 V a.c.

17 Separation

The terminals of each of these parts are connected together during the test. The test voltage is chosen from Table 5 of GB 9706.1-2007.

22 Moving parts

See informative note in Annex AAA. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB 9706.15-2008 be delivered?Answer: The full copy PDF of English version of GB 9706.15-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 9706.15-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 9706.15-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 9706.15-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 9706.15-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 9706.15-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 9706.15-2008?

A step-by-step guide to download PDF of GB 9706.15-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 9706.15-2008".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9