GB/T 24786-2025 (GB 24786-2009) PDF EnglishUS$145.00 · In stock · Download in 9 seconds
GB 24786-2009: Single-use medical poly (vinyl chloride) examination gloves Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB 24786: Historical versions
Similar standardsGB 24786-2009: Single-use medical poly (vinyl chloride) examination gloves---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB24786-2009NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.140; 83.140.99 G 45 Single-use Medical Poly (vinyl chloride) Examination Gloves [ISO 11193-2.2006, Single-use Medical Examination Gloves - Part 2. Specification for Gloves Made from Poly (vinyl chloride), MOD] Issued on. DECEMBER 15, 2009 Implemented on. OCTOBER 1, 2010 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 1 Scope... 4 2 Normative References... 4 3 Classification... 5 4 Materials... 5 5 Sampling and Selection of Test Pieces... 6 6 Requirements... 6 7 Packaging... 10 8 Marking... 10 Appendix A (normative) Water Impermeability... 13ForewordIn this Standard, the content of Chapter 6 and 8.2 is mandatory; the remaining is recommended. This Standard adopts and modifies ISO 11193-2.2006 Single-use Medical Examination Gloves - Part 2.Specification for Gloves Made from Poly (vinyl chloride), MOD (English version). This Standard was re-drafted in accordance with ISO 11193-2.2006. In accordance with the domestic manufacturing technology of single-use medical poly (vinyl chloride) examination gloves, this Standard makes the following technical modifications. ---The breaking force index of single-use medical poly (vinyl chloride) examination gloves before and after ageing is modified from 7.0 N (see 6.3.2 in ISO 11193- 2.2006) into 4.8 N (see Table 3). For ease of use, this Standard has the same structure as ISO 11193-2.2006.In addition, the following editorial modifications are made. ---The foreword of the previous international standard is deleted; ---The phrase “this International Standard” is modified into “this Standard”; ---Decimal point “.” is used to replace comma “,”, which is used as the decimal point; ---“The language used for marking shall be as agreed upon between the interested parties” in 8.1 is deleted. In this Standard, Appendix A is normative. This Standard was proposed by China Petroleum and Chemical Industry Association. This Standard shall be under the jurisdiction of Latex Products Sub-Technical Committee of National Technical Committee 35 on Rubber & Products of Standardization Administration of China (SAC/TC 35 /SC 4). The drafting organizations of this Standard. Shandong LANFAN Plastic Co., Ltd.; Zhuzhou Rubber & Plastics Industry Research & Design Institute of China Rubber Group; Beijing Institute of Medical Device Testing. The main drafters of this Standard. Liu Wenjing, Zhang Yongchen, Deng Yizhi, Zhang Xiaoli. Single-use Medical Poly (vinyl chloride) Examination Gloves Warning. users of this Standard shall be familiar with normal laboratory practices. This Standard does not involve any safety issues, even those related to it are not an exception. Users shall establish corresponding safety and health specifications; ensure the compliance with national regulations.1 ScopeThis Standard stipulates the requirements for non-sterile or packaged sterile poly (vinyl chloride) gloves used to prevent cross infection between patients and users during medical examination and diagnosis, or, the requirements for poly (vinyl chloride) gloves used to prevent cross infection during treatment of patients. It also includes poly (vinyl chloride) gloves used for the disposal of contaminated medical materials.2 Normative ReferencesThrough the reference in this Standard, clauses of the following documents become clauses of this Standard. In terms of references with a specific date, all the subsequent modification sheets (excluding the corrected content) or the revised editions are not applicable to this Standard.3 ClassificationFinished gloves are classified into the following types.4 MaterialsThe gloves involved in this Standard shall be made of poly (vinyl chloride) materials. For ease of wearing, surface treatment agents, lubricants, powders or polymer coatings may be used.5 Sampling and Selection of Test PiecesFor the purpose of arbitration, gloves shall be sampled and inspected in accordance with the requirements in GB/T 2828.1.The inspection level and acceptance quality limit (AQL) shall comply with the stipulations in Table 1.6 RequirementsTensile properties shall be determined in accordance with GB/T 528.From each glove, cut 3 test pieces. Take the median as the result. Sterilized gloves shall identify the type of sterilization as required.7 PackagingIf gloves are sterilized, they shall be individually packed, or in pairs.8 MarkingUnit package refers to a single glove or a pair of gloves being packed in a packaging bag.Appendix A(normative) Water Impermeability The minimum diameter is 60 mm; it shall be able to hold 1,000 mL of water. In addition, it shall have sufficient length to fix the gloves, as it is shown in Figure A.1. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. |