HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 16150-2025 (GB/T 16150-1995) PDF English

US$110.00 · In stock · Download in 9 seconds
GB/T 16150-1995: Sieve test for dustable and wettable powders of pesticides
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure

GB/T 16150: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 16150-2025EnglishRFQ ASK 3 days Determination method of sieve analysis for pesticides Valid
GB/T 16150-1995English110 Add to Cart 0-9 seconds. Auto-delivery Sieve test for dustable and wettable powders of pesticides

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 16150-1995
      

Similar standards

GB/T 19136   GB/T 19378   GB/T 19137   GB/T 43174   

GB/T 16150-1995: Sieve test for dustable and wettable powders of pesticides

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT16150-1995
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 65.100 G 23 Sieve test for dustable and wettable powders of pesticides ISSUED ON: DECEMBER 21, 1995 IMPLEMENTED ON: AUGUST 01, 1996 Issued by: The State Bureau of Quality and Technical Supervision

Table of Contents

1 Scope ... 3 2 Method ... 3 Additional information: ... 6 Sieve test for dustable and wettable powders of pesticides

1 Scope

This method is applicable to the sieve test for dustable and wettable powders of pesticides.

2 Method

2.1 Dry sieving method (applicable to powders) 2.1.1 Method summary: Dry the sample in the oven to constant weight and cool it naturally to room temperature. After the sample and the atmosphere reach humidity equilibrium, weigh a specimen. Sieve to the end point with a test sieve of appropriate hole size. Weigh the residue in the sieve. Calculate the fineness (if the dried sample is easy to absorb moisture, the sample must be placed in a desiccator to cool, and the contact between the sample and the atmospheric environment shall be minimized to complete the screening). 2.1.2 Instruments Test sieve: appropriate aperture, with matching receiving plate and cover. Glass dish: known mass. Brush: 2.5 cm soft flat brush. Constant temperature oven: temperature control accuracy within 100°C is ±2°C. Desiccator. 2.1.3 Determination steps 2.1.3.1 Sample preparation Adjust the oven to the appropriate temperature according to the characteristics of the sample. A sufficient amount of sample is dried in the oven to constant weight. The sample is then naturally cooled to room temperature and equilibrated with atmospheric humidity for later use. If the sample absorbs moisture easily, it shall be cooled to room temperature in the desiccator. And try to minimize contact with the atmospheric environment. 2.1.3.2 Determination Weigh 20 g of specimen (accurate to 0.1 g). Place in a test sieve of appropriate aperture that fits the receiving plate. Close the lid. Carry out the test in one of two ways. a. Vibrating screen method Install the test sieve on the vibrating screen machine and vibrate, while tapping the left and right sides of the receiving plate alternately. After 10 min, turn off the vibrating screen machine. Let the dust settle for a few seconds and then remove the sieve lid. Use a brush to remove any material blocking the mesh. Also disperse soft clumps in the sieve, but hard particles shall not be crushed. Cover the screen cover and turn on the vibrating screen machine. Repeat the above process until less than 0.01 g is sifted within 2 min. Transfer the residue in the sieve to a glass dish and weigh it. b. Hand screening method Hold the screen cover and both sides of the receiving plate firmly with both hands. On the operating table with rubber cover, repeatedly touch the bottom of the left and right sides of the receiving plate with the operating table to vibrate the screen. Adjust the screen position clockwise from time to time (or counterclockwise). Allow the dust to settle for a few seconds before removing the lid. Use a brush to clean away material blocking the mesh. Also disperse soft clumps, but hard particles shall not be crushed. Repeat vibrating and sieving until less than 0.01 g is sieved within 2 min. Transfer the residue in the sieve to a glass dish and weigh it. 2.2 Wet sieving method (applicable to wettable powders) 2.2.1 Method summary Place the weighed specimen in a beaker, moisten and dilute it. Pour into a moistened test sieve. Rinse directly with gentle running water. Then place the test sieve in a basin filled with water and continue washing. Transfer the residue in the sieve to a beaker. Dry the residue and weigh. Calculate fineness. 2.2.2 Instruments Test sieve: appropriate aperture, and equipped with matching receiving plate and lid. Beakers: 250 mL, 100 mL. Oven: temperature control accuracy within 100°C is ±2°C. Glass rod: with rubber cover. Desiccator. 2.2.3 Determination steps 2.2.3.1 Wetting of specimen ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.