HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY/T 1671-2020 PDF English

US$175.00 · In stock · Download in 9 seconds
YY/T 1671-2020: Ultrasound biopsy guide
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YY/T 1671-2020English175 Add to Cart 0-9 seconds. Auto-delivery Ultrasound biopsy guide Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YY/T 1671-2020
      

Similar standards

YY/T 1676   YY/T 1749   YY/T 1601   YY/T 1668   

YY/T 1671-2020: Ultrasound biopsy guide

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT1671-2020
YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.50 C 41 Ultrasound biopsy guide 超声探头穿刺架 ISSUED ON: FEBRUARY 25, 2020 IMPLEMENTED ON: MARCH 01, 2022 Issued by: National Medical Products Administration

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Structure type and nomenclature ... 5 5 Requirements... 5 6 Test methods ... 7 Appendix A (Informative) Typical types of biopsy guide structure ... 13 Ultrasound biopsy guide

1 Scope

This Standard specifies the terms and definitions, structure type and nomenclature, requirements, and test methods for ultrasound biopsy guide. This Standard applies to the ultrasound biopsy guide. This Standard does not apply to inductive navigation devices, such as magnetic navigation devices.

2 Normative references

The following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. GB/T 14233.1-2008 Test methods for infusion, transfusion, injection equipment for medical use - Part 1: Chemical analysis methods GB/T 16886.1 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process Pharmacopoeia of the People's Republic of China (2015)

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Ultrasound biopsy guide A device used for guiding and fixing puncture instruments such as puncture needles, drainage tubes, treatment or dosing devices, etc., used in conjunction with intracavity or in vitro ultrasound probes in ultrasound diagnosis and treatment operations. 3.2 In-plane puncture 5.2.2 The puncture instrument shall not be obstructed during its travel in the needle groove. And the puncture instrument must not shake significantly. 5.3 In-plane puncture accuracy 5.3.1 The puncture needle shall be clearly displayed within the image scanning range of the ultrasound imaging equipment. 5.3.2 For ultrasound imaging equipment with puncture guide lines, when the detection depth is less than or equal to 4 cm, the distance FROM the point on the straight line (where the image displayed by the puncture needle on the biopsy guide manufacturer's expected application range is located) TO the puncture guide line shall not exceed the value specified by the biopsy guide manufacturer. But the maximum distance must not exceed 5 mm. When the detection depth is greater than 4 cm, the distance FROM the point on the straight line (where the image displayed by the puncture needle on the expected application range is located) TO the puncture guide line shall not exceed the value specified by the biopsy guide manufacturer. But the maximum distance must not exceed 10 mm. 5.3.3 For ultrasound imaging equipment that only displays the puncture guide area, when the detection depth is less than or equal to 4 cm, the distance FROM the point on the straight line (where the image displayed by the puncture needle on the biopsy guide manufacturer's expected application range is located) TO the centerline of the puncture guide area shall not exceed the value specified by the biopsy guide manufacturer. But the maximum distance must not exceed 5 mm. When the detection depth is greater than 4 cm, the distance FROM the point on the straight line (where the image displayed by the puncture needle on the expected application range is located) TO the centerline of the puncture guide area shall not exceed the value specified by the biopsy guide manufacturer. But the maximum distance must not exceed 10 mm. The image displayed by the puncture needle on the ultrasound imaging equipment must not exceed the scope of the puncture guide area. 5.3.4 For situations where there is no guide line or no guide line is used, the requirements of 5.3.1 shall be met. 5.3.5 For a biopsy guide equipped with multiple needle grooves, each needle groove shall meet the requirements of 5.3.1. In addition, each needle groove must meet the requirements of 5.3.2 or 5.3.3 or 5.3.4. 5.4 Out-plane puncture accuracy The puncture point shall meet the depth position requirements of the biopsy guide manufacturer's expected application range. The distance BETWEEN the actual puncture point image of the puncture needle on the image AND the set puncture target position shall meet the value specified by the biopsy guide manufacturer. However, when the detection depth is less than or equal to 4 cm, the maximum distance must not exceed 5 mm. When the detection depth is greater than 4 cm, the maximum distance must not exceed 10 mm. 5.5 Particular requirements for reusable biopsy guide 5.5.1 In the accompanying documents, the manufacturer shall specify the sterilization method and effective service life of the reusable biopsy guide. 5.5.2 After sterilization according to the requirements of 5.5.1, the reusable biopsy guide can still meet the applicable performance requirements in 5.1 to 5.4. 5.6 Particular requirements for single-use biopsy guide 5.6.1 When leaving the factory, the single-use biopsy guide shall be sterile. It shall be sterile after a confirmed sterilization process. 5.6.2 If the single-use biopsy guide is sterilized with ethylene oxide, the residual amount of ethylene oxide shall not exceed 10 μg/g. 5.7 Biological evaluation The biopsy guide shall be biologically evaluated in accordance with the requirements of GB/T 16886.1. The evaluation result shall conclude free of biological hazards.

6 Test methods

6.1 Appearance Use visual observation or hand touching to check. It shall meet the requirements of 5.1. 6.2 Usability 6.2.1 Use actual operations. It shall meet the requirements of 5.2.1. 6.2.2 Use actual operations. It shall meet the requirements of 5.2.2. At the same time, its shaking must not affect the puncture accuracy. 6.3 In-plane puncture accuracy 6.3.1 Install the biopsy guide with the probe in the application range expected by the biopsy guide manufacturer. Carry out the test in the sink. The image shall ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YY/T 1671-2020 be delivered?

Answer: The full copy PDF of English version of YY/T 1671-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 1671-2020_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1671-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YY/T 1671-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 1671-2020?

A step-by-step guide to download PDF of YY/T 1671-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 1671-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9