Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Aug 8, 2020)
HOME  COVID-19   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

QC/T 1026-2016

Chinese Standard: 'QC/T 1026-2016'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
QC/T 1026-2016English135 Add to Cart 0--10 minutes. Auto immediate delivery. Performance and determination of PVC slush skin of automotive instrument panel Valid QC/T 1026-2016
QC/T 1026-2016Chinese18 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID QC/T 1026-2016 (QC/T1026-2016)
Description (Translated English) Performance and determination of PVC slush skin of automotive instrument panel
Sector / Industry Automobile & Vehicle Industry Standard (Recommended)
Classification of Chinese Standard T20
Classification of International Standard 43.040.60
Word Count Estimation 11,160
Date of Issue 2016-01-15
Date of Implementation 2016-07-01
Quoted Standard GB/T 250-2008; GB/T 251-2008; GB/T 1040.1-2006; GB/T 1040.3-2006; GB/T 2411-2008; GB/T 2918-1998; GB/T 3920-2008; GB 8410; GB/T 9754-2007; GB/T 16422.1-2006; GB/T 16422.2-1999; ISO 105-B06-1998; ISO 105-B06 AMD 1-2002; ISO 6452-2000; ISO 6721-1-2011; ISO 6721-4-2012
Drafting Organization Changchun Fu Wei-Johnson Controls Auto Parts System Co., Ltd.
Administrative Organization National Automotive Standardization Technical Committee
Regulation (derived from) ?Ministry of Industry and Information Technology Bulletin 2016 No.3
Summary This standard specifies the technical requirements and test methods for the skin of slush dashboard for automobiles. This standard applies to polyvinyl chloride powder as the main raw material for automotive slush dashboard skin (hereinafter referred to as the skin).

QC/T 1026-2016
QC
AUTOMOBILE INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 43.040.60
T 20
Performance and determination of PVC
slush skin of automotive instrument panel
汽车聚氯乙烯搪塑仪表板
表皮性能及检测
ISSUED ON. JANUARY 15, 2016
IMPLEMENTED ON. JULY 1, 2016
Issued by. Ministry of Industry and Information Technology of the
People's Republic of China
Table of Contents
Foreword ... 5 
1 Scope ... 6 
2 Normative references ... 6 
3 Terms and definitions ... 7 
4 Technical requirements ... 8 
5 Test methods ... 9 
6 Inspection rules ... 15 
7 Storage ... 15 
Performance and determination of PVC
slush skin of automotive instrument panel
1 Scope
This Standard specifies technical requirements and test methods for PVC slush
skin of automotive instrument panel.
This Standard is applicable to PVC slush skin of automotive instrument panel
mainly made of polyvinyl chloride powder (hereinafter referred to as the slush
skin).
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 250-2008, Textiles - Tests for color fastness - Grey scale for assessing
change in color
GB/T 251-2008, Textiles - Tests for color fastness - Grey scale for assessing
staining
GB/T 1040.1-2006, Plastics - Determination of tensile properties - Part 1.
General principles
GB/T 1040.3-2006, Plastics - Determination of tensile Properties - Part 3.
Test Conditions for Films and Sheets
GB/T 2411-2008, Plastics and ebonite - Determination of indentation
hardness by means of a durometer (shore hardness)
GB/T 2918-1998, Plastics - Standard atmospheres for conditioning and
testing
GB/T 3920-2008, Textiles - Tests for color fastness - Color fastness to
rubbing
GB 8410, Flammability of automotive interior materials
GB/T 9754-2007, Paints and varnishes - Determination of specular gloss of
non-metallic paint films at 20° 60° and 85°
GB/T 16422.1-2006, Plastics - Methods of the exposure to laboratory light
sources - Part 1. General guidance
GB/T 16422.2-1999, Plastics - Methods of exposure to laboratory light
sources Part 2. Xenon - Arc sources
ISO 105-B06.1998, Textiles - Tests for color fastness -- Part B06. Color
fastness and ageing to artificial light at high temperatures. Xenon arc fading
lamp test
ISO 105-B06 AMD 1.2002, Textiles - Tests for color fastness - Part B06.
Color fastness and ageing to artificial light at high temperatures. Xenon arc
fading lamp test
ISO 6452.2000, Rubber- or plastics-coated fabrics - Determination of fogging
characteristics of trim materials in the interior of automobiles
ISO 6721-1.2011, Plastics - Determination of dynamic mechanical properties
- Part 1. General principles
ISO 6721-4.2012, Plastics - Determination of dynamic mechanical properties
- Part 4. Tensile vibration - Non-resonance method
ISO 6721-11.2012, Plastics - Determination of dynamic mechanical
properties - Part 11. Glass transition temperature
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 slush skin of instrument panel
surface softening decorative piece that the polyvinyl chloride powder is
attached to the surface of the preheated mold by rotating the uniform station,
and the interior of the automobile produced by the molding process of "loading"
the powdered material by plasticizing and cooling without pressure is decorative;
the shape of the mold is consistent
3.2 positive skin
decorative surface after softening parts are made
3.3 negative skin
surface that is relative to the positive skin
Gloss meter. shall meet the requirements of GB/T 9754-2007.
5.2.2 Test steps
Take 3 samples according to GB/T 9754-2007. Determine the gloss of the
positive skin of the sample by a single angle measurement (60°). The test
results are expressed as the arithmetic mean of the three samples.
5.3 Color
5.3.1 Instruments
Color difference meter (also called spectrophotometer). can choose 45°/0° or
d/8° measurement method, generally agreed by both parties.
5.3.2 Test steps
At least perform 5 individual measurements, the measurement position is
distributed over the entire surface. The results are generally agreed by both
parties.
5.4 Thickness
5.4.1 Instruments
Thickness gauge. accuracy is not less than 0. 01 mm, thickness gauge load is
393 g, presser foot diameter is 10 mm. The thickness gauge load and the
presser foot diameter can be agreed by the supplier and the purchaser.
5.4.2 Test steps
Take 3 pieces of 50 mm × 50 mm samples. Place the patterned side of the
sample face down on the gauge. Select two points, each point is not less than
5 mm from the edge of the sample, and the distance between the two points is
not less than 10 mm. Determine the thickness of the sample, to the nearest of
0.0.1 mm. The test results are expressed as the arithmetic mean of 6 test points.
5.5 Areal density
5.5.1 Instruments
Analytical balance. to the nearest of 0.1 mg.
5.5.2 Test steps
Take 3 flat pieces of 100mm × 100mm samples. Weigh separately on the
analytical balance, to the nearest of 0.1 mg. And convert the measurement
results to grams per square meter. The test results are expressed as the
arithmetic mean of 3 samples, in integer.
Reference material. DOP (dioctyl phthalate), requiring analytically pure DOP.
5.9.2 Test steps
The sample shall be dried in the dryer for at least 24 h before the test.
The test is carried out in accordance with the provisions of ISO 6452.2000. Take
2 samples with a diameter of 80 mm and place them in the glass of the atomizer
(the front side of the skin is placed up). Press the sample with a metal ring. Take
a glass at the same time and put in (10.0±0.2) g of DOP. Place the glass in the
oil bath. Put the sealing ring, the weighed aluminum pin (G0), the round glass
plate, the filter paper and the cooling plate on the edge of the glass cup. The oil
temperature is controlled at (100±0.5)°C, the temperature of the cooling plate
is controlled at (21±1)°C, and is maintained (16±0.2) h. After removing the
cooling plate, filter paper, and glass plate in turn, carefully remove the aluminum
foil, and place the fogged side of the aluminum foil upward, and store it in the
dryer for 3.5h ~ 4h. Weigh the aluminum foil (G1) that has been fogged and
store in the dryer. The difference between G1 and G0 is the test result. The
sample results are expressed as the arithmetic mean of two samples.
It shall confirm whether the condensation value of DOP is between (4.9±0.25)
mg (only when the oil temperature is 100°C). If the condensation value of DOP
is not in this range, the test shall be invalid, the cause shall be analyzed, and
the test shall be repeated.
In special cases, the test temperature and storage time can be negotiated
between the supplier and the purchaser.
5.10 Resistance to Xenon aging
5.10.1 Equipment
Xenon lamp aging chamber. in accordance with GB/T 16422.1-2006.
The filter system uses a combination of a glazed glass inner filter and a
uranium-calcium glass outer filter.
Reference material. No. 6 blue wool, in accordance with ISO 105-B06.1998.
5.10.2 Test steps
According to the provisions of GB/T 16422.2-1999, take 3 pieces of 140mm ×
70mm samples and 1 blue wool as reference material of the same size. Place
the sample and reference material in a Xenon lamp aging chamber. The sample
is facing the light source. Carry out 5 cycles of exposure tests under the
conditions that the black mark temperature is (100±3)°C, the test chamber
temperature (65±3)°C, the relative humidity is (20±10)%, and the spectral
intensity of 420 nm is 1.2 W/m2, without spray. The determination of the end
Level 1. feel no smell;
Level 2. feel the smell, but not irritating to people;
Level 3. obviously feel the smell, but not irritating to people;
Level 4. obviously feel the smell, irritating to people;
Level 5. the smell is very strong to people;
Level 6. the smell is very strong and unbearable.
5.15 Glass transition temperature <......