QB/T 2806-2017 PDF English
US$245.00 · In stock · Download in 9 secondsQB/T 2806-2017: Thermostatic faucets Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid QB/T 2806: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
QB/T 2806-2017 | English | 245 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Thermostatic faucets
| Valid |
QB 2806-2006 | English | 180 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
[Replaced by QB/T 2806-2017] Thermostatic faucets
| Obsolete |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: QB/T 2806-2017
QB/T 2806-2017: Thermostatic faucets---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/QBT2806-2017
LIGHT INDUSTRY STANDARD OF
THE PEOPLE��S REPUBLIC OF CHINA
ICS 91.060
Classification number. Y71
Registration number. 59735-2017
Replacing QB/T 2806-2006
Thermostatic faucets
Issued on. JULY 07, 2017
Implemented on. JANUARY 01, 2018
Issued by. Ministry of Industry and Information Technology of PRC
Table of Contents
Foreword... 3
1 Scope... 5
2 Normative references... 5
3 Terms and definitions... 6
4 Classification and naming... 8
5 Conditions of use... 8
6 Materials... 9
7 Supporting devices... 9
8 Requirements... 9
9 Single-handle three-control thermostatic faucet... 17
10 Test methods... 19
11 Inspection rules... 24
12 Marking, packaging, transportation, storage... 27
Appendix A (Normative) Size of faucet... 29
Appendix B (Normative) Test of temperature stability of outlet water... 44
Appendix C (Normative) Safety test (all models)... 47
Appendix D (Normative) Test of service life... 48
Appendix E (Normative) Test of flow regulator��s torque... 50
Appendix F (Normative) Test of temperature regulator��s torque... 51
1 Scope
This standard specifies the terms and definitions, classification and naming,
conditions of use, materials, supporting devices, requirements, single-handle
three-control thermostatic faucets, test methods, inspection rules, marking,
packaging, transportation and storage of thermostatic faucets.
This standard applies to the cold-water & hot-water mixed faucet which is at
nominal pressure, has an ordinary-water-pressure of not more than 0.5 MPa
and a high-water-pressure of not more than 2 MPa, a cold-water temperature
of 4 ��C ~ 29 ��C and a hot-water temperature of 45 ��C ~ 85 ��C, is mounted on
the sanitary facilities in the washroom (toilets, bathroom, etc.), kitchen and so
on, whose outlet water temperature is automatically controlled by the pre-
selected temperature.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 2828.1-2012 Sampling procedures for inspection by attributes - Part 1.
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 5270-2005 Metallic coatings on metallic substrates - Electrodeposited
and chemically deposited coatings - Review of methods available for testing
adhesion
GB/T 6461-2002 Methods for corrosion testing of metallic and other
inorganic coatings on metallic substrates - Rating of test specimens and
manufactured articles subjected to corrosion tests
GB/T 7306.1 Pipe threads with 55 degree thread angle where pressure-tight
joints are made on the threads - Part 1.Parallel internal and taper external
threads
GB/T 7306.2 Pipe threads with 55 degree thread angle where pressure-tight
joints are made on the threads - Part 2.Taper internal and external threads
GB/T 7307 Pipe threads with 55 degree thread angle where pressure-tight
joints are not made on the threads
GB/T 9286-1998 Paints and varnishes - Cross cut test for films
GB/T 10125-2012 Corrosion tests in artificial atmospheres - Salt spray tests
GB 18145-2014 Ceramic cartridge faucets
GB/T 23447 Shower outlets for bathing
GB/T 23448 Flexible hose for sanitary tapware
JC/T 932 Drainage fittings for sanitary wares
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Thermostatic faucets
The faucets which, when the inlet water temperature and pressure change
within a certain range, automatically adjust the incoming flowrate of cold-
water and hot-water, to stabilize the outlet water temperature in a certain
range.
3.2
Single handle, double handle
The quantity of handles or handwheels which control the outlet water
temperature, flowrate, open-close of the faucets. Single handle refers to
using one handle or handwheel to control the outlet temperature or both
flowrate and open-close. Double handle refers to using two handles or
handwheels to respectively control the outlet water temperature, flowrate
and open-close.
3.3
Single handle double control, single handle three control
Single-handle double control refers to using one handle or handwheel to
control the outlet water temperature and open-close. Single-handle three-
control refers to using one handle or handwheel to control the outlet water
temperature, flowrate, open-close.
3.4
Close the inlet water
The open-close of the faucet is realized by opening-closing the cold and hot
inlet water.
3.5
Close the outlet water
The open-close of faucet is directly achieved by opening-closing the mixed
water.
3.6
Safety with cold-water or hot water failure
When cold-water or hot-water is out of supply, the temperature control device
reacts quickly to regulate the hot-water or cold-water supply, so that the
outlet water temperature and flowrate reach the specified value, thereby
avoiding burns of human body or uncomfortable sense.
4 Classification and naming
4.1 Classification
4.1.1 According to the number of control handles, it is divided into single-handle
and double-handle.
4.1.2 According to the type of temperature control, it is divided into constant-
temperature faucet (hereinafter referred to as T) and constant-temperature
constant-pressure faucet (hereinafter referred to as TP).
4.1.5 According to the use pressure, it is divided into ordinary-water-pressure
and high-water-pressure.
4.2 Naming
The name shall include the number of control handles, the type of temperature
control, the location of use, the form of installation, the pressure of use.
Example.
5 Conditions of use
5.1 Working pressure
5.1.1 Ordinary-water-pressure. water supply pressure 0.1 MPa ~ 0.5 MPa. If it
exceeds 0.5 MPa, it shall add a relief valve.
5.1.2 High-water-pressure. water supply pressure 0.1 MPa ~ 2.0 MPa. It is
recommended for the water pressure for normal use to be 0.3 MPa ~ 1.5 MPa.
5.2 Temperature for use of medium
Cold-water temperature 4 ��C ~ 29 ��C, hot-water temperature 45 ��C ~ 85 ��C. It
is recommended for the hot-water temperature for normal use to be 50 ��C ~
75 ��C.
6 Materials
6.1 All materials in direct contact with drinking water used in the product shall,
under the conditions of use as specified in this standard, neither cause harm to
human health, nor cause any changes in water quality, appearance, taste, smell
of drinking water.
6.2 Parts of faucets that are in contact with water shall not be made of easily-
corroded materials such as zinc alloys.
7 Supporting devices
7.1 The sprinkler matched with the faucet shall comply with the provisions of GB/T 23447.
7.2 The hose matched with the faucet shall comply with the provisions of GB/T 23448.
7.3 The drain fittings matched with the faucets shall comply with the provisions of JC/T 932.
8 Requirements
8.1 Appearance
8.1.1 The surface of the plating shall be uniform in gloss and shall not have
defects such as peeling, cracking, charring, exposed bottom, falling-off, dark
spots and obvious pitting, burrs and the like.
8.2 Surface performance
8.2.1 Adhesion strength of coating and plating
8.2.1.1 Adhesion strength of coating
The cross-cut test shall be carried out according to 10.2.1.1, it shall reach the
requirements of grade-1.
8.2.2 Surface corrosion resistance
After the acid salt spray test according to 10.2.2, it shall not be lower than the
grade-9 appearance rating (RA) requirements in Table 1 of the GB/T 6461-2002.
8.3 Thread
8.3.1 The external sealing pipe thread of the product shall comply with the
provisions of GB/T 7306.1 or GB/T 7306.2.The external non-sealing pipe
thread of the product shall comply with the provisions of GB/T 7307.
8.3.2 The surface of the thread shall be smooth and there shall be no obvious
defects such as dents and broken teeth.
8.4 Assembly
8.4.1 The assembled handle or handwheel shall be light, stable, free from
jamming. The transfer switch shall be light, stable, free from jamming when
lifted or pulled. The pull-up part and the lift-up bar of the transfer switch shall be
firmly connected. The rotating outlet pipe of the faucet shall be rotated light and
free from jamming.
8.5 Size
The size of the faucet shall comply with the provisions of Appendix A. The other
sizes shall be as agreed upon by the supplier and the purchaser.
8.6 Precipitation of metal contaminants (applicable to washing faucet and
basin faucet)
8.7 Use performance
8.7.1 Mechanical performance for hydraulic-resistance
The mechanical performance for hydraulic-resistance of the faucet shall comply
with the requirements of Table 2.
8.7.4 Stability of outlet water temperature
8.7.4.1 T-type thermostatic faucet
When the water supply temperature is constant and one of the hot-water and
cold-water supply pressures changes by 20%, as shown in Figure 1, in the first
5 s, the time during which the pulse peak of the outlet water temperature is
+3 ��C above the initial set value shall be not more than 1.5 s; the time during
which the pulse peak exceeds the set time by -5 ��C shall be not more than 1 s.
After 5 s, the deviation between the outlet water temperature and the set outlet
water temperature shall not exceed �� 2 ��C.
8.7.6 Maximum outlet water temperature
Under the temperature conditions of use of medium in 5.2, the faucet shall be
able to limit the maximum outlet water temperature to �� 49 ��C.
8.7.7 Service life
After the service life reaches the requirements of Table 7, it shall comply with
the requirements of Table 7.After the service life test, the temperature regulator
and the flow regulator shall be free from jamming or loss of control.
8.7.8 Resistance to installation load
The installation load resistance of the faucet��s connection pipe thread shall
comply with the provisions of GB 18145-2014.
8.7.9 Resistance to use load
8.7.9.1 After the flow regulator is subjected to the (6.0 �� 0.5) N m torque test,
the flow regulator shall be free from defects such as deformation, jamming,
cracking, loss of control of positioning.
8.7.9.2 After the temperature regulator is subjected to the (6.0 �� 0.5) N m
torque at the total-cold or total-hot position and the safety temperature-limit
button is subjected to the (1.7 �� 0.5) N m torque, the temperature regulator
shall be free from such defects as deformation, jamming, cracking, loss of
control of positioning.
8.7.9.3 The operating torque for normal use shall not exceed 1.7 N m.
9 Single-handle three-control thermostatic faucet
9.1 Classification
9.1.1 According to working pressure. see 5.1.
9.1.2 According to the method of opening and closing the mixed water. it is
divided into closing the inlet water faucet and closing the outlet water faucet.
9.2 Use temperature of medium
According to the requirements of 5.2.
9.3 Performance of use
9.3.1 Sealing performance
9.3.2 Flowrate
9.3.2.1 The flowrate of ordinary-hydraulic faucet shall comply with the provisions of 8.7.3.
9.3.3 Temperature stability of outlet water
9.3.3.1 Outlet water��s temperature stability of ordinary-hydraulic nozzle
It shall meet the requirements of 8.7.4.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of QB/T 2806-2017 be delivered?Answer: The full copy PDF of English version of QB/T 2806-2017 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of QB/T 2806-2017_English with my colleagues?Answer: Yes. The purchased PDF of QB/T 2806-2017_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- QB/T 2806-2017 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds. Question 5: Should I purchase the latest version QB/T 2806-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version QB/T 2806-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
How to buy and download a true PDF of English version of QB/T 2806-2017?A step-by-step guide to download PDF of QB/T 2806-2017_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "QB/T 2806-2017". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|