HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 801-2004 PDF English

US$170.00 · In stock · Download in 9 seconds
JJG 801-2004: Verification Regulation of Chemiluminescent NO/NOx Analyzers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JJG 801: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
JJG 801-2004English170 Add to Cart 0-9 seconds. Auto-delivery Verification Regulation of Chemiluminescent NO/NOx Analyzers Valid
JJG 801-1993English279 Add to Cart 3 days Verification Regulation of Chemiluminescent NO/NO Analyzer Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: JJG 801-2004
      

Similar standards

JJG 846   JJG 821   JJG 551   

JJG 801-2004: Verification Regulation of Chemiluminescent NO/NOx Analyzers

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJG801-2004
JJG NATIONAL METROLOGICAL VERIFICATION REGULATIONS OF THE PEOPLE’S REPUBLIC OF CHINA Chemiluminescent NO/NOx Analyzers ISSUED ON: NOVEMBER 09, 2004 IMPLEMENTED ON: MAY 09, 2005 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Table of Contents

1 Scope ... 5 2 Overview ... 5 3 Metering performance requirements ... 5 4 General technical requirements ... 6 4.1 Appearance and power-on inspection ... 6 4.2 Insulation resistance... 6 4.3 Insulation strength ... 6 5 Measuring instrument control ... 6 5.1 Verification conditions ... 7 5.2 Verification items ... 7 5.3 Verification methods ... 8 5.4 Processing of verification results ... 10 5.5 Verification cycle ... 10 Annex A Description of reference materials ... 11 Annex B Inner page format of verification certificate and verification result notice ... 12 Annex C Verification record format ... 13 Carbon Monoxide and Carbon Dioxide Infrared Gas Analyzer

1 Scope

This Standard applies to the initial verification, subsequent verification and in- use inspection of chemiluminescence nitrogen oxide analyzer.

2 Overview

The basic detection principle of the chemiluminescence nitrogen oxide analyzer (hereinafter referred to as the "instrument") is: When nitric oxide reacts with ozone (O3), generate excited nitrogen dioxide molecules (NO2). The excited nitrogen dioxide molecule emits light when it returns to the ground state. The intensity of the emitted light is proportional to the concentration of nitric oxide. Detect the luminous intensity to detect the concentration of nitric oxide. The chemical reaction formula is: Where, hv - Emitted light. If there is nitrogen dioxide gas in the sample gas, the sample gas first passes through the inherent converter of the instrument to convert nitrogen dioxide into nitric oxide (NO). Then with ozone (O3), the above chemiluminescence reaction occurs. The difference between the total amount of nitrogen oxides (NO+NO2) detected (NOx) and nitric oxide is equal to the content of nitrogen dioxide (i.e. NOx−NO=NO2). The structure of the instrument generally includes: ozone generator, converter, detector, electronic unit.

3 Metering performance requirements

The measurement performance requirements of the instrument are specified in Table 1. 5.3 Verification methods 5.3.1 Appearance and power-on inspection Use visual inspection and hand feel method according to requirements of 4.1.1 and 4.1.2. 5.3.2 Insulation resistance measurement The tested instrument is not connected to the power supply. Turn on its power switch. Connect one terminal of the insulation resistance meter to the phase and middle connection lines of the power plug. The other terminal is connected to the ground terminal of the instrument. Use the insulation resistance meter to measure the insulation resistance of the tested instrument. 5.3.3 Insulation strength measurement The tested instrument is not connected to the power supply. Turn on its power switch. Connect the two wires of the insulation strength measuring instrument to the phase wire (or neutral wire) of the power plug of the tested instrument and the chassis. Make the voltage rise steadily to 1500V. Maintain 1min. Then make the voltage drop steadily to 0V. No breakdown and arcing shall occur during the test. 5.3.4 Calibration before verification Power on the instrument to warm up for at least 1.5h. The total flow rate monitored by the vent flow meter is greater than the flow rate required by the instructions. Access zero-point gas first. Adjust zero point. Access NO standard gas that is about 85% of the range. After the indicated value stabilizes, adjust the instrument's NO and NOx indicated values to be consistent with the standard values. 5.3.5 Verification of indication error According to the flow requirements during calibration, access approximately 20%, 50%, and 85% of the range of NO standard gas, respectively. Record the stable value. Perform three times for each point. Take the arithmetic average of three times as the value indicated by the instrument. Calculate the result according to formula (1). Take the maximum value of the absolute value of the result as the indication error (ΔC). For multi-range instruments, select high, medium, and low ranges for verification. Where, Where, - Average NO2 of three measurements; C0 - NO2 mixed gas concentration. 5.3.9 Drift verification The drift of the instrument includes zero-point drift and range drift. After the instrument warms up, in the highest range of the instrument, access zero-point gas. At this time, record the stable reading as Z0. Then access NO standard gas with a content of about 85% of range. Read the stable display value as S0. Conduct continuous operation for 6h. Access zero-point gas every 1h and record the zero-point value of the instrument as Zi. Access the same standard gas mentioned above. Record the stable indication of the instrument as Si. Calculate the zero drift (ΔZi) according to formula (4). Calculate the range drift (ΔSi) according to formula (5). Take the largest absolute value ΔZi as the zero drift (ΔZ). The ΔSi with the largest absolute value is taken as the range drift (ΔS). Where, Zi - Zero point value of the ith pass through zero gas; Si - Indication value of the ith accessed standard gas; R - Full range of the instrument. 5.4 Processing of verification results For qualified instruments verified according to this Regulation, a verification certificate will be issued. For instruments that fail to pass the verification, a verification result notification will be issued, and the unqualified items shall be indicated. 5.5 Verification cycle The verification period of the instrument is 2 year. After repairing or replacing the main components of the instrument, it shall be submitted for inspection at any time.

Annex A

Description of reference materials Because the use environment of the instrument is different, the range of the instrument is different. Quite a few chemiluminescence nitrogen oxide analyzers have a very low range of use, which generally is less than 10×10-6. Therefore, the gas standard substance used in the verification can also be configured with low-concentration standard gas using the ISO recognized mass flow dynamic gas distribution device. However, the high-concentration standard gas used in dynamic gas distribution must be traced to a national certified standard material with an uncertainty of 1% (k=3). The current typical standard gas dilution device is based on the above principle. According to the needs of the inspected instrument, use high-purity nitrogen as diluent gas. Dilute high-concentration gas reference materials. Various standard gases with 10-8~10-2 content can be prepared. Its main technical performances are as follows: 1) Flow range: (10/2000/3000/5000) mL/min (optional); 2) Flow indication error limit: ±0.5%; 3) Time required to convert the concentration: < 60s. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of JJG 801-2004 be delivered?

Answer: The full copy PDF of English version of JJG 801-2004 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJG 801-2004_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 801-2004_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- JJG 801-2004 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version JJG 801-2004?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 801-2004 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of JJG 801-2004?

A step-by-step guide to download PDF of JJG 801-2004_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJG 801-2004".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9