HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1832-2020 PDF English

US$365.00 · In stock · Download in 9 seconds
JJF 1832-2020: Calibration Specification of (1mT~2.5T) Magnetometers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
JJF 1832-2020English365 Add to Cart 0-9 seconds. Auto-delivery Calibration Specification of (1mT~2.5T) Magnetometers Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: JJF 1832-2020
      

Similar standards

JJF 1234   JJF 1576   JJG 376   JJF 2000   

JJF 1832-2020: Calibration Specification of (1mT~2.5T) Magnetometers

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJF1832-2020
JJF NATIONAL METROLOGY TECHNICAL SPECIFICATION Calibration Specification for (1 mT~2.5 T) Magnetometers Issued on: JANUARY 17, 2020 Implemented on: APRIL 17, 2020 Issued by. State Administration for Market Regulation

Table of Contents

Introduction... 5 1 Scope... 6 2 References... 6 3 Terms and units of measurement... 6 3.1 magnetometer... 6 3.2 zero drift... 6 3.3 basic range... 6 4 General... 6 5 Metering characteristics... 8 5.1 Magnetic flux density indication error... 8 5.2 Difference between the forward and reverse indications of the probe... 8 5.3 Zero drift... 8 5.4 Up and down variation... 8 6 Calibration conditions... 8 6.1 Environmental conditions... 8 6.2 Measurement standards and other equipment... 8 7 Calibration items and calibration methods... 10 7.1 Calibration items... 10 7.2 Calibration methods... 10 8 Expression of calibration results... 16 9 Recalibration interval... 18 Appendix A Influence of the angle between the Hall plate and the magnetic field on the measurement results... 19 Appendix B Example of evaluating the measurement uncertainty of the indication error of magnetic flux density... 21 Appendix C Magnetometer calibration raw record format... 26 Appendix D Calibration certificate inner page format... 28 Calibration Specification for (1 mT~2.5 T) Magnetometers

1 Scope

This Specification applies to the calibration of 1 mT ~ 2.5 T DC magnetic field magnetometers, and also to the calibration of the DC magnetic field measurement part of multifunctional magnetometers.

2 References

The following documents are referred to in this Specification. JJF 1013-1989 Terms in common use and their definitions for the magnetic metrology For dated references, only the dated version applies to this Specification; for undated references, the latest version (including all amendments) applies to this Specification.

3 Terms and units of measurement

3.1 magnetometer An instrument used for measuring magnetic field strength or magnetic flux density (magnetic induction intensity). 3.2 zero drift The amount by which the magnetometer reading deviates from zero when the probe is placed in a zero magnetic field cavity. 3.3 basic range The measuring range with the best maximum permissible error of magnetic flux density.

4 General

A magnetometer is an instrument used to measure the magnetic flux density (magnetic induction intensity) of an object at a point in space, among which the Hall effect magnetometer is the most typical. Magnetometers are divided into digital magnetometers and pointer magnetometers according to the display mode. Their principle structure block diagrams are shown in Figure 1 and Figure 2, respectively. Magnetometer probes are divided into radial probes and axial probes according to the direction of the measured magnetic field.

5 Metering characteristics

5.1 Magnetic flux density indication error The maximum allowable error generally does not exceed ± (0.02% ~ 10%). 5.2 Difference between the forward and reverse indications of the probe The difference between the forward and reverse indications of the magnetometer probe generally does not exceed its maximum allowable error. 5.3 Zero drift In the zero magnetic field cavity, the zero drift of the magnetometer generally does not exceed 1/3 of its maximum allowable error. 5.4 Up and down variation The up and down variation of a pointer magnetometer generally does not exceed the error coefficient value related to its range value. Note. The above indicators are not applicable to qualification judgment and are for reference only.

6 Calibration conditions

6.1 Environmental conditions When calibrating the magnetometer, the environmental conditions shall meet the requirements of Table 1. 6.2 Measurement standards and other equipment The magnetometer calibration device consists of a zero magnetic field cavity, a magnetic field coil (Helmholtz coil, solenoid, etc.), an electromagnet, an excitation power supply, a DC ammeter, a probe position adjustment device, a standard magnetometer (or a magnetometer standard table), etc. The calibration device must be verified (or calibrated) against a higher-level measurement standard, and its combined standard uncertainty must not exceed 1/3 of the maximum allowable error of the calibrated magnetometer. 6.2.1 Zero magnetic field cavity The magnetic flux density in the zero magnetic field cavity is no more than 1×10-6 T. 6.2.2 Magnetic field coil When the magnetic flux density of the magnetic field is in the range of 1 mT ~ 100 mT, the magnetic field generator can use a magnetic field coil. The magnetic field coil can be a Helmholtz coil, a solenoid coil, or the like. In the uniform area of the coil magnetic field, the error caused by the magnetic field uniformity shall be no more than 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer, and the error introduced by the coil constant shall be no more than 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer. 6.2.3 Electromagnet When the magnetic flux density of the magnetic field is in the range of 10 mT ~ 2.5 T, the magnetic field generator can be an electromagnet. The pole surfaces of the electromagnet shall be flat and the two pole surfaces shall be parallel. In the electromagnetic field homogeneity region, the error caused by the magnetic field homogeneity shall be no more than 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer. 6.2.4 Excitation power supply The change in the excitation power supply current within 60 s shall not exceed 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer. 6.2.5 DC ammeter The DC ammeter can be integrated into the excitation power supply or placed separately to measure the excitation current of the magnetic field coil. The error shall not exceed 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer. 6.2.6 Probe position adjustment system The probe position adjustment system can adjust the spatial position of the standard magnetometer probe and the calibrated magnetometer probe, and has the function of probe direction rotation to ensure that the probe Hall plate is perpendicular to the magnetic field direction. The error caused by adjusting the probe position and direction shall not exceed 1/5 of the absolute value of the maximum allowable error of the calibrated magnetometer. 6.2.7 Standard magnetometer The standard magnetometer may be a nuclear magnetic resonance magnetometer, a Hall effect magnetometer, or the like. The allowable error shall not exceed 1/3 of the absolute value of the maximum allowable error of the calibrated magnetometer, and the error change within one year shall not exceed its maximum allowable error.

7 Calibration items and calibration methods

7.1 Calibration items The calibration items are shown in Table 2. 7.2 Calibration methods 7.2.1 Appearance and power-on inspection 7.2.1.1 The housing, exposed switches, function buttons and corresponding markings of newly produced magnetometers shall be intact; magnetometers in use and after repair shall not have damage or defects that affect normal operation. 7.2.1.2 The product name and model, manufacturer name, factory serial number, etc. of the magnetometer shall be clearly marked. 7.2.1.3 The accessories of the magnetometer shall be complete. The probe and magnetometer shall be matched and their instruction manuals shall be provided. 7.2.1.4 The connection wires of the magnetometer shall not be loose; the switches and buttons shall function normally; it shall be able to work normally after power is turned on. 7.2.2 Zero drift 7.2.2.1 Preheat the magnetometer to be calibrated according to its instructions. 7.2.2.2 Place the magnetometer probe to be calibrated in the zero magnetic field cavity and adjust its range to the lowest range. 7.2.2.3 Zero the calibrated magnetometer and select a recording time based on the requirements (if no requirements are available, 60 seconds may be selected). Record the maximum value (Bmax) and minimum value (Bmin) of the readings within this time. The zero drift is calculated according to Formula (2). Where. Bp – zero drift of the calibrated magnetometer, T; Bmax – maximum value of magnetometer reading, T; Bmin – minimum value of magnetometer reading, T. 7.2.3 Magnetic flux density indication error 7.2.3.1 Selection of calibration points Select the calibration points according to the usage requirements. If there is no requirement, select by referring to the following method. -- Pointer type magnetometer. For basic range, select points with digital graduation lines within the measuring range as calibration points, and the number of calibration points shall be no less than 3 points. For non-basic range, select two points as calibration points. the maximum point of basic range error and the upper limit point. -- Digital type magnetometer. The basic range can select (but not limited to) the upper limit of the range, 80% range point, 60% range point, 40% range point, and 20% range point as calibration points; for non-basic range, generally select 3 points. The indication error of the magnetic flux density value of the calibrated magnetometer is calculated according to Formula (3). Where. Ex – indication error of magnetic flux density of the calibrated magnetometer; Bx – indication value of the calibrated magnetometer; Bs – magnetic field flux density reference value (standard value). 7.2.3.2 Magnetic field generator ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of JJF 1832-2020 be delivered?

Answer: The full copy PDF of English version of JJF 1832-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJF 1832-2020_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1832-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- JJF 1832-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of JJF 1832-2020?

A step-by-step guide to download PDF of JJF 1832-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJF 1832-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9