HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

HJ 630-2011 PDF English

US$150.00 · In stock · Download in 9 seconds
HJ 630-2011: Technical guideline on environmental monitoring quality management
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
HJ 630-2011English150 Add to Cart 0-9 seconds. Auto-delivery Technical guideline on environmental monitoring quality management Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: HJ 630-2011
      

Similar standards

GB/T 24021   GB/T 23384   HJ 168   

HJ 630-2011: Technical guideline on environmental monitoring quality management

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/HJ630-2011
Environmental Protection Standard of the People’s Republic of China Technical guideline on environmental monitoring quality management ISSUE ON. SEPTEMBER 8, 2011 Implemented on: NOVEMBER 1, 2011 Issued by. Ministry of Environmental Protection Announcement of Ministry of Environmental Protection of the People’s Republic of China [2011] No. 65 In order to implement the "Environmental Protection Law of the People's Republic of China”, protect the environment, protect human health, regulate environmental monitoring, it is now approving and publishing "Ambient air PM10 and PM2.5 - Gravimetric method" and other 2 standards as the national environmental standards. The standards’ name and number are as follows. 1. Ambient air PM10 and PM2.5 - Gravimetric method (HJ 618-2011); 2. Stationary source emission. Determination of sulphur dioxide. Non-dispersive infrared absorption method (HJ 629-2011); 3. Technical guideline on environmental monitoring quality management (HJ 630 -2011). Above standards shall be implemented from November 1, 2011; they are published by the China Environmental Science Press; content of the standards may be found from the website of Ministry of Environmental Protection (bz.mep.gov.cn). From the date of implementation of above standards, the following national environmental standards becomes obsolete, the standard name and number are as follows. Determination methods of airborne particulate concentration (GB 6921-86). Notice is hereby given. September 8, 2011

Table of Contents

Foreword ... 4 1 Application Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 5 4 Basic requirements of environmental monitoring quality system ... 7 5 Quality assurance and quality control methods of environmental monitoring process... 13 Appendix A ... 22 References and Original Chinese Documents... 25

Foreword

In order to implement the "Environmental Protection Law of the People's Republic of China", "Water Pollution Prevention Law of the People's Republic of China", "Air Pollution Prevention Law of the People's Republic of China" and "Solid Waste Pollution Prevention Law of the People's Republic of China”; to ensure the monitoring of the quality of the environment; and to improve the quality of management of environmental monitoring, this Standard is formulated. This Standard specifies the basic requirements of environmental monitoring quality system, and quality assurance and quality control methods of environmental monitoring process. This Standard is first-time released. Appendix A of this Standard is informative. This Standard was organized and developed by Division of Technical Standard of Ministry of Environmental Protection. Main drafting organizations of this Standard. China Environmental Monitoring Station, and Jiangsu Province Environmental Monitoring Center. This Standard is approved by the Ministry of Environmental Protection on September 8, 2011. This Standard shall be implemented from November 1, 2011. The standard shall be interpreted by Ministry of Environmental Protection. Technical guideline on environmental monitoring quality management

1 Application Scope

This Standard specifies the basic requirements of environmental monitoring quality system, quality assurance and quality control methods of environmental monitoring process. This Standard applies to various environmental monitoring activities; it also applies to Environmental Protection Administration Departments to manage the environmental monitoring; other agencies who engage in environmental monitoring activities may also refer to this Standard.

2 Normative references

The following documents or their provisions are referenced in this Standard. For undated references, the latest versions apply to this Standard. GB/T 4091 Shewhart control charts GB/T 4883 Judgment and processing of statistical processing of data and interpretation of the normal sample outliers GB/T 8170 Rules of rounding off for numerical values & expression and judgment of limiting values HJ 168 Environmental monitoring - Technical guideline on drawing and revising analytical method standards

3 Terms and definitions

prevent cross-contamination. Toxic and hazardous wastes shall be properly handled, or disposed by qualified organization. It shall establish and maintain management procedures of safety operations; ENSURE that chemicals, toxic substances, hazardous biological, radiation, high temperature, high pressure, impact, water, air, fire, electricity, other endangered factors and environments are under effective control; and HAVE corresponding emergency process measures. 4.12.3 When monitoring at the spot, environmental conditions such as weather during the monitoring period, operational conditions such as water, electricity, gas supply, other working conditions; business conditions and change (stability) of pollutant conditions shall meet the monitoring requirements. It shall have such measures to ensure personnel safety and equipment safety. 4.13 Monitoring method 4.13.1 According to the requirements of relevant standards or technical specifications; it shall choose those methods which can meet the monitoring requirements and quality requirements to implement the monitoring activities. In principle, preferably SELECT those methods of national environmental protection standards, other national standards and other industrial standards; it may also use those methods of international standards and foreign standards; or those monitoring analytical methods which have been recognized widely with authoritativeness. Selected methods shall go through the experimental validation; and FORM the related records meeting the quality monitoring requirements such as method-detection limit, precision and accuracy. 4.13.2 For those standard methods which are used beyond the predetermined scope, self-expansion and modification, they shall be confirmed through experiment; so as to prove that the method is applicable to the intended use; and to form the method to validate reports. Confirmation contents include. sample collection, sample disposal, transportation procedures; method-detection limit; measuring range; precision; accuracy; selection and anti-interference capability of the method. 4.13.3 Standard and work instructions related to monitoring work shall be controlled, effective and enforced; they shall be easily accessible. shall the aligned with the last digit of dependent variable. 5.6.3 Judgment and treatment of outliers. Judgment and treatment of outliers shall be executed per GB/T 4883; when there is an abnormally high value, reasons shall be found out the reasons; unexplained abnormal high value shall not be removed at will. 5.6.4 Data verification and auditing. 5.6.4.1 Raw data and copied data shall be verified. Suspicious data shall be verified with original recording of sample analysis. 5.6.4.2 Monitoring raw data shall be signed off by the monitoring personnel and verification personnel. Monitoring personnel shall be responsible for completing the original records; verification personnel shall verify if the data recording is in integrity; if there is error when copying or keying into the computer, if the data is abnormal; and consider the following factors. monitoring methods, monitoring conditions, significant digits of data, data calculation and process procedure, the legal units of measurement and quality control data. 5.6.4.3 The auditing personnel shall audit the accuracy, logic, rationality and comparability of the original data and copied data; FOCUS on the following factors. monitoring sites; monitoring conditions; comparison with historical data; logic relation between the total amount and sub-amount; the same monitoring factor at the same monitoring site; the changing trend among the multiple continuous monitoring results; samples from the same monitoring site and at same time (period); correlation and rationality of analysis result of related monitoring factors and so on. 5.6.5 Expression of monitoring report 5.6.5.1 Monitoring results shall adopt legal units of measurement. 5.6.5.2 When measurement results of parallel samples are within the allowable deviation, their average value shall be reported in measurement results. 5.6.5.3 When monitoring results are below the method-detection limit, USE "ND" to conditions) may affect the monitoring results during sampling process, it shall attach a detailed description; -- LIST out the standards or specifications related to sampling methods or procedures; and the description of deviation, additions or deletions; -- When necessary, ADD introduction such as project construction, production process, pollutants’ generation and control; -- Other information including quality control of whole monitoring process, quality assurance, relevant charts, reference materials, and necessary recommendations. References and Original Chinese Documents [1] HJ 630-2011 Technical guideline on environmental monitoring quality management. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of HJ 630-2011 be delivered?

Answer: The full copy PDF of English version of HJ 630-2011 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of HJ 630-2011_English with my colleagues?

Answer: Yes. The purchased PDF of HJ 630-2011_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- HJ 630-2011 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of HJ 630-2011?

A step-by-step guide to download PDF of HJ 630-2011_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "HJ 630-2011".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9