GB/T 45321-2025 PDF English
US$380.00 · In stock · Download in 9 secondsGB/T 45321-2025: Measuring method for electric and photometric parameters of filament light sources for power-driven vehicles Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB/T 45321-2025 | English | 380 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Measuring method for electric and photometric parameters of filament light sources for power-driven vehicles
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 45321-2025
GB/T 45321-2025: Measuring method for electric and photometric parameters of filament light sources for power-driven vehicles ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT45321-2025
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 43.040.20
CCS T 38
Measuring Method for Electric and Photometric Parameters
of Filament Light Sources for Power-driven Vehicles
Issued on: FEBRUARY 28, 2025
Implemented on: SEPTEMBER 1, 2025
Issued by. State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword... 3
1 Scope... 4
2 Normative References... 4
3 Terms and Definitions... 4
4 Principle... 5
4.1 Electric Parameters... 5
4.2 Total Flux... 6
4.3 Chromaticity Coordinates... 7
5 Instruments and Equipment... 8
5.1 Electric Parameters... 8
5.2 Total Flux... 9
5.3 Chromaticity Coordinates... 10
5.4 Instrument and Equipment Traceability... 11
6 Measurement Conditions... 11
6.1 Working Environment... 11
6.2 Ageing... 11
6.3 Ignition Location and Direction... 11
6.4 Stabilization... 12
6.5 Voltage and Current... 12
7 Measurement Steps and Data Processing... 12
7.1 Pre-heating of Measurement Equipment... 12
7.2 Measurement of Electric Parameters... 12
7.3 Measurement of Total Flux... 13
7.4 Measurement of Chromaticity Coordinates... 15
8 Test Report... 16
Appendix A (informative) Ignition Direction of Light Sources in the Integrating Sphere
... 18
Appendix B (informative) Typical Examples of Light Source Power-on and Lamp
Holder Voltage Monitoring Contacts... 24
Appendix C (normative) Measurement Method for Light Source Absorption Correction
Factor... 27
Measuring Method for Electric and Photometric Parameters
of Filament Light Sources for Power-driven Vehicles
1 Scope
This document specifies the measurement principles, instruments and equipment, measurement
conditions, measurement steps, data processing, and test reports of the electric and photometric
parameters, total flux, and chromaticity coordinates of filament light sources for power-driven
vehicles.
This document is applicable to filament light sources used for power-driven vehicle road
lighting and light signal devices and systems (hereinafter referred to as the “light sources”).
Filament light sources used for other road vehicles may take this as a reference.
2 Normative References
The contents of the following documents constitute indispensable clauses of this document
through the normative references in the text. In terms of references with a specified date, only
versions with a specified date are applicable to this document. In terms of references without a
specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 2900.65 Electrotechnical Terminology - Lighting
GB/T 26178 The Measurement of Luminous Flux
GB/T 43081-2023 Lamps and Light Sources for Road Vehicles - Dimensional, Electrical and
Luminous Requirements
JJG 247-2008 Standard Incandescent Lamp for Total Luminous Flux
3 Terms and Definitions
The terms and definitions defined in GB/T 2900.65 and GB/T 26178, and the following are
applicable to this document.
3.1 filament light sources
A type of light sources, in which, the only element that generates and emits light when powered
is one or multiple filaments.
3.2 test voltage
b) The grade index is not lower than 0.01% and the rated power is not lower than 1 W.
5.2 Total Flux
5.2.1 Integrating sphere
The integrating sphere shall comply with the following requirements.
a) Diameter of the integrating sphere. while taking into account the photoelectric
responsivity, the size of the integrating sphere shall be large enough to avoid relatively
large errors caused by uneven distribution of the integrating sphere response due to
the accessories inside the integrating sphere and the light source under test. The
diameter of the integrating sphere is not less than 1.0 m.
b) Accessories and coating of the integrating sphere. all accessories inside the sphere
will affect the measurement results. Accessories (such as screens, wires and light
source brackets, etc.) shall be as small and as few as possible. The inside of the sphere
and the surface of its accessories shall be coated with a white coating, which has good
chemical stability and neutral spectral diffuse reflection characteristics, and a
reflectivity of not less than 85%.
c) Layout of light source and screen. usually the center of the light source filament is
placed at the center of the sphere, and the center of the screen is on the line connecting
the center of the sphere and the center of the detector window, at a distance of 2/3 of
the radius of the sphere from the center of the sphere, and the surface of the screen is
perpendicular to the line. The function of the screen is to prevent the light of the light
source from directly irradiating the detector. On this premise, the screen shall be as
small as possible.
d) Auxiliary light source. the integrating sphere is equipped with an auxiliary light
source to perform absorption measurements. The auxiliary light source emits
radiation that covers the entire visible light wavelength range. The auxiliary light
source also has a screen to prevent its direct light from irradiating the detector or the
light source under test.
5.2.2 Photometer
The photometer shall comply with the following requirements.
a) The detector of the photometer has stable performance, high sensitivity, good linearity
and fast response. The spectral sensitivity of the combination of the correction light
filter and the integrating sphere conforms to the spectral luminous efficiency function
V(λ) of the CIE photopic standard photometric observer;
b) The grade of the photometer is not lower than Grade 1, and the number of significant
digits read is not less than 4.
5.2.3 Spectroradiometer
The spectroradiometer shall comply with the following requirements.
a) The spectral wavelength range covers at least 380 nm ~ 780 nm;
b) The wavelength error is within 0.2 nm;
c) The non-linear error of the instrument is within 1% (A light source);
d) The bandwidth (full width at half maximum) and scanning interval are not greater
than 5 nm;
e) The relative spectral power distribution indication error is within 2%.
5.2.4 Standard lamp
The standard lamp should be a standardized (for example. the BDX series) small total flux
standard incandescent lamp, or a light source that has been screened by ageing from
conventional filament light source products for power-driven vehicles.
The ageing screening process is as follows.
a) From conventional products, select several light sources with glass bulbs free of
bubbles or scratches, and with good filaments, lamp holders and overall appearance;
b) After ageing as described in 6.2, at the test voltage, measure the initial value of the
total flux and the current;
c) At the test voltage, keep the power on for 10 hours, control the initial current, and
measure its total flux. Calculate the relative deviation from the initial value, and keep
the light sources with a deviation within 0.8% and proceed with the next step of test;
d) Repeat step c), until the total power-on ageing time reaches 30 hours, and retain the
light sources that meet the ageing screening conditions for measurement.
There shall be no less than 3 standard lamps of each specification, and the level of the standard
lamps shall at least comply with Level 2 in JJG 247-2008.
The standard lamps shall be stored in a room temperature, dry and vibration-free environment
without corrosive gases, and shall be protected from impact and overload during use.
5.3 Chromaticity Coordinates
5.3.1 Spectroradiometer
The spectroradiometer shall comply with the requirements of 5.2.3.
5.3.2 Standard lamp
Standard lamps shall comply with the requirements of 5.2.4.
5.4 Instrument and Equipment Traceability
The standard lamps and instruments shall be verified or calibrated by a metrology institution
and used within their validity period.
6 Measurement Conditions
6.1 Working Environment
The measurement of light sources shall be carried out in an environment with a temperature of
23 C 5 C and a humidity of less than 80%. Temperature control equipment (such as. air
conditioners, heaters, etc.) shall not be placed in a location that allows airflow and radiant heat
to be directly transmitted to the thermometer or photometer.
6.2 Ageing
Before measurement, use the test voltage to continuously ignite for 1 h to age the light source.
For dual-filament light sources, each filament shall be respectively aged. For light sources for
which multiple test voltages are specified, the highest test voltage value shall be used.
During ageing, the light source reference axis and the filament are in a horizontal state. For a
dual-filament light source equipped with a light distribution screen, the light distribution screen
shall be located below the low-beam filament. If the light source has an axial filament, the
longer filament support shall be located above the filament.
6.3 Ignition Location and Direction
When measuring the total flux, the light source shall be located at the center of the integrating
sphere, and its direction is.
a) The reference axis and the filament are in a horizontal state, and the filament axis is
parallel to the screen;
b) For light sources with transverse filaments (the filament axis is perpendicular to the
reference axis), the top of the glass bulb faces the screen;
c) For light sources with axial filaments (the filament axis is parallel to the reference
axis), the longer filament support shall be located above the filament;
d) For light sources with a light distribution screen and emitting asymmetric light, the
light distribution screen shall be located below the low-beam filament and the side of
the light distribution screen edge with an inclined angle faces the screen.
Examples of the ignition directions of different types of light sources within the sphere are
provided in Appendix A.
6.4 Stabilization
Stabilization means that the parameters of the light source do not significantly change within a
certain period of time. During stabilization and measurement, the operating environment of the
light source shall be the same. Before each measurement, the halogen light source shall be
ignited at the test voltage for 4 minutes ~ 5 minutes, and other light sources shall be ignited at
the test voltage for 2 minutes ~ 3 minutes, all light sources shall be ignited for 10 min when
measuring the chromaticity coordinates. During the last minute of the ignition of the light
source, the light output is measured every 20 seconds. When the deviation between the
maximum and minimum values of the three readings is within 0.25%, stabilization is achieved.
If the requirement is still not met after 15 minutes, the test can be started and the observed
fluctuations shall be recorded.
6.5 Voltage and Current
When measuring voltage, the voltmeter wiring should be drawn from both ends of the lamp
holder near the filament position of the light source to monitor the voltage at the lamp end of
the light source under test. When measuring current with power on, a component with a
relatively small contact resistance shall be used to clamp the lamp holder of the light source,
for example, a special lamp holder for measurement, to reduce the contact resistance and
measurement errors. Typical examples of light source power-on and lamp holder voltage
monitoring are shown in Appendix B.
Voltage and current tests use the four-wire line power supply.
7 Measurement Steps and Data Processing
7.1 Pre-heating of Measurement Equipment
Before measuring electric and photometric parameters, the equipment shall be turned on for
pre-heating, so as to stabilize its performance. If the total flux is to be measured, a light source
with a power similar to that of the light source under test shall be ignited in the integrating
sphere for not less than 30 minutes, the sphere wall shall be baked to de-humidify, and the
detector shall be pre-illuminated.
7.2 Measurement of Electric Parameters
The measurement steps are as follows.
a) After the light source under test has been aged in accordance with the requirements
of 6.2, install it to the center of the sphere in the mode of 6.3 and in accordance with
the provisions of 6.5, connect it to the measurement system shown in Figure 1 or
Figure 2.Adjust the power output, so that the reading of the V2 meter is the test voltage.
After the light source reaches the stabilization described in 6.4, respectively read the
displayed values u and U of the V1 and V2 voltmeters in Figure 1 or read the voltmeter
reading U and the ammeter reading I in Figure 2.The voltage adjustment process shall
d) In accordance with Formula (7), calculate the total flux of the light source under test.
Where,
Φn---the total flux of the light source under test;
Φt---the total flux of the standard lamp;
pn(λ)---the relative spectral power distribution of the light source under test;
Pt(λ)---the relative spectral power distribution of the standard lamp;
V(λ)---the spectral luminous efficiency function of the CIE photopic standard
photometric observer;
λ---the wavelength test interval of the (relative) spectral power distribution of the
light source.
7.3.3 Total flux absorption correction factor
When the overall dimensions of the standard lamp and the light source under test greatly differ
or the glass bulb form and lamp holder shape are obviously different, an auxiliary light source
shall be used to measure the absorption correction factor k of each type of light source under
test. The method shall comply with the provisions of Appendix C. After the absorption
correction, the total flux Φ of the light source under test is calculated in accordance with
Formula (8).
7.4 Measurement of Chromaticity Coordinates
7.4.1 The measurement is carried out in a dark room or dark box. The dark room or dark box
shall have no light leakage and be well sealed and dustproof. The entire space should be set
with low-reflectivity materials, such as. matte black or matte gray. Measures shall be taken to
ensure that the photometer detector is not affected by reflected light from objects in the space.
When getting ready to measure, the stray light received by the photometer detector is not greater
than 0.005 lx.
7.4.2 The chromaticity coordinates are measured using a spectroradiometer with the detector
measuring within a right cone subtended by a minimum of 5° and a maximum of 15°, with the
apex of the cone located at the center of the filament.
7.4.3 Place the standard lamp in a dark room or dark box and in the same method as in 7.3.2 a),
calibrate the spectroradiometer.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 45321-2025 be delivered?Answer: The full copy PDF of English version of GB/T 45321-2025 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 45321-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 45321-2025_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 45321-2025 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB/T 45321-2025?A step-by-step guide to download PDF of GB/T 45321-2025_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 45321-2025". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|