GB/T 36004-2018 PDF English
US$90.00 · In stock · Download in 9 secondsGB/T 36004-2018: Food contact surfaces cleaning and disinfection efficacy test method - ATP bioluminescence method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB/T 36004-2018 | English | 90 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Food contact surfaces cleaning and disinfection efficacy test method - ATP bioluminescence method
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 36004-2018
GB/T 36004-2018: Food contact surfaces cleaning and disinfection efficacy test method - ATP bioluminescence method ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT36004-2018
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.100.40
Y 43
Food contact surfaces cleaning and disinfection
efficacy test method - ATP bioluminescence method
Issued on: MARCH 15, 2018
Implemented on: OCTOBER 01, 2018
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 4
4 Principle ... 5
5 ATP test methods ... 5
6 Laboratory cleaning and disinfection efficacy evaluation method ... 8
Food contact surfaces cleaning and disinfection
efficacy test method - ATP bioluminescence method
1 Scope
This Standard specifies a test method for the evaluation of food contact
surfaces cleaning and disinfection efficacy, based on the principle of adenosine
triphosphate (ATP) bioluminescence.
This Standard is applicable to the evaluation of food contact surfaces cleaning
and disinfection efficacy by ATP bioluminescence method.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 6682 Water for analytical laboratory use - Specification and test
methods
3 Terms and definitions
For the purpose of this document, the following terms and definitions apply.
3.1
food contact surfaces
Surfaces such as food packaging materials and containers, and utensils,
tableware, equipment, floors, walls in food processing, production and
management process that may be in direct contact with food.
3.2
cleaning
Process of removing the contamination from the item so as to achieve the
intended use or further processing requirement.
After starting and calibrating the instrument according to the instrument
instructions, fully PRESS the sampling rod into the test tube to activate the ATP
luminescence reaction. Quickly OSCILLATE back and forth the sampling rod
for about 5 s, MIX the reagents thoroughly, and INSERT the test tube into the
instrument for test. The measured results are expressed as relative light unit
(RLU).
5.1.5 Precautions
Note the following when using the handheld ATP bioluminescence tester smear
method.
a) Do not touch the sampling head and the smearing surface during the
smearing process;
b) The operator shall perform a consistent smearing method to obtain
repeatable results;
c) Once the sampling is completed, it is recommended to test immediately;
once activated, the test shall be carried out within 30 s;
d) The smear sampling rods provided by different manufacturers shall be
tested with their own matching instruments. The test results can refer to
the standards provided by the instrument supplier. People can be
engaged in test after being trained and deemed qualified by the supplier;
e) Different instrument test values cannot be compared together. When using
different instruments from different manufacturers, the results may be
inconsistent.
5.2 Method 2. benchtop chemiluminescence analyzer test method
5.2.1 Reagents and materials
Unless otherwise stated, only analytically pure reagents and third- or higher-
grade water as specified in GB/T 6682 are used in the analysis.
5.2.1.1 ATP test kit. The kit includes cell lysate, assay buffer, fluorescein-
luciferase mixture, ATP standard solution.
5.2.1.2 Sterile water. Experimental water after autoclaving. The sterilization
condition is. pressure 103 kPa, steam sterilization at 121 °C ~ 126 °C for 20
min. This condition is used for the sterilization operations in this Standard.
5.2.1.3 Autoclaved metal tweezer.
5.2.1.4 Filter paper. CUT the filter paper into 5 cm × 5 cm size and use it after
c) The ATP in the sample after cracking is not too stable at room temperature
so that it shall operate at 4 °C or on ice. ATP can be stabilized on ice for
up to 6 hours;
d) Bacteria can survive and multiply in sterile water, which can cause ATP
interference, so the quality of sterile water shall be checked regularly.
6 Laboratory cleaning and disinfection efficacy
evaluation method
6.1 Instruments
6.1.1 Autoclave.
6.1.2 Constant temperature incubator.
6.1.3 Centrifuge.
6.1.4 Biological safety cabinet.
6.2 Reagents and materials
6.2.1 E. coli strain.
6.2.2 LB liquid medium. Preparation method. ADD 10 g of tryptone, 5 g of yeast
extract, and 10 g of NaCl into 950 mL of experimental water, SHAKE the
container until the solute is dissolved. USE 5 mol/L NaOH to adjust the pH to
7.0, ADD experimental water to 1 L, and CARRY OUT steam sterilization at 103
kPa for 20 min.
6.2.3 Disposable plastic sterile petri dish with a diameter of 9 cm.
6.2.4 Sterilized utility knife.
6.2.5 Sterilized cotton swab.
6.2.6 Sterilized centrifuge tube.
6.3 Artificial containment
6.3.1 Bacterial culture
After activation of the E. coli strain, take 1 mL of E. coli culture medium to
inoculate into 100 mL of sterilized LB liquid medium, and culture in a 37 °C
incubator at a rate of 220 r/min for 24 h.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 36004-2018 be delivered?Answer: The full copy PDF of English version of GB/T 36004-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 36004-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36004-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 36004-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB/T 36004-2018?A step-by-step guide to download PDF of GB/T 36004-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 36004-2018". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|