HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (9 Feb 2025)

GB/T 1003-2016 English PDF (GB 1003-2008, GB 1003-1999)

GB/T 1003-2016_English: PDF (GB/T1003-2016)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 1003-2016English230 Add to Cart 0--9 seconds. Auto-delivery Three phases plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions Valid GB/T 1003-2016
GB 1003-2008English319 Add to Cart 3 days [Need to translate] Three phases plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions Obsolete GB 1003-2008
GB 1003-1999English319 Add to Cart 3 days [Need to translate] Three phases plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions Obsolete GB 1003-1999
GB/T 1003-1980EnglishRFQ ASK 3 days [Need to translate] Types, basic parameters and dimensions of three phase plugs and sockets Obsolete GB/T 1003-1980


BASIC DATA
Standard ID GB/T 1003-2016 (GB/T1003-2016)
Description (Translated English) Three phases plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 14,128
Date of Issue 2016-12-13
Date of Implementation 2017-07-01
Older Standard (superseded by this standard) GB 1003-2008
Drafting Organization (China) Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Bulls Group Co., Ltd., Zhejiang Zhengtai Construction Electric Co., Ltd., TCL-Legrand International Electrotechnical (Huizhou) Co., Ltd., Beijing Branch to Bo Electronic Technology Co., Ltd. (China) Co., Ltd. Shanghai Branch (China) Co., Ltd. Shanghai Branch Co., Ltd., Beijing Electric Co., Ltd., , Simon Electric (China) Co., Ltd., Yuehua Holding Group Co., Ltd., Shenzhen Hangjia Chiyuan Electric Co., Ltd., Nanhai District, Foshan City, Ping Chau Nanping Wire Factory, Feijia Electric Appliance Group Co., Ltd., Dongguan City, or wire and cable limited Company, Huizhou City Hongfeng industry limited
Administrative Organization National Electrical Appliances Standardization Technical Committee (SAC/TC 67)
Regulation (derived from) National Standard Notice No.27 of 2016
Proposing organization China Electrical Appliances Industry Association
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China, China National Standardization Administration Committee

BASIC DATA
Standard ID GB 1003-2008 (GB1003-2008)
Description (Translated English) Three phases plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions
Sector / Industry National Standard
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 8,890
Date of Issue 2008-09-24
Date of Implementation 2009-08-01
Older Standard (superseded by this standard) GB 1003-1999
Quoted Standard GB/T 2900.70-208; GB 2099.1-2008; GB/T 1184-1996
Drafting Organization China Electric Apparatus Research Institute
Administrative Organization National Standardization Technical Committee of electrical accessories
Regulation (derived from) Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard specifies the household and similar purposes -phase plug and socket type, basic parameters and dimensions. This standard applies to home and family environment similar occasions, the AC frequency of 50Hz, rated voltage of 440V, rated current not exceeding 32A three-phase three-phase plugs and fixed or portable socket-outlets.

BASIC DATA
Standard ID GB 1003-1999 (GB1003-1999)
Description (Translated English) Three phases plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions
Sector / Industry National Standard
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 8,862
Date of Issue 1999/8/2
Date of Implementation 2000/10/1
Older Standard (superseded by this standard) GB 1003-1980
Quoted Standard GB/T 10964-89; GB 2099.1-1996; GB/T 1184-1996
Regulation (derived from) Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Proposing organization Ministry of Machinery Industry
Issuing agency(ies) State Quality and Technical Supervision


GB/T 1003-2016 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.120.30 K 30 Replacing GB 1003-2008 Three phases plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions ISSUED ON: DECEMBER 13, 2016 IMPLEMENTED ON: JULY 01, 2017 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Technical requirements and test methods ... 5  5 Types, basic parameters and dimensions ... 6  Foreword This Standard was drafted in accordance with the rules given in GB/T 1.1-2009. This Standard replaces GB 1003-2008 “Three phases plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions”. Compared with GB 1003-2008, the main technical changes in GB 1003-2008 are as follows: - added the use method for special gauges in 5.1; - added the description of the position of the ground electrode and the neutral electrode in 5.2; - modified "The distance between the plug pin and the edge shall ensure that it meets the requirements for protection against electric shock" to "The distance between the plug pin of the live plug and the edge shall not be less than 7.5mm" in 5.3; - added the minimum distance between insert sleeve and mating surface in 5.4; - added the shapes and dimensions of the end of the pin for the plugs in Figure 1, Figure 3; - added Figure 3 Three-phase five-wire plug and its dimensions; - added Figure 4 Three-phase five-wire socket and its dimensions; - deleted original Figure 3 Three-phase plug inner gauge and original Figure 4 Three-phase plug external gauge; combined them as Figure 5 Three- phase five-wire plug gauge; - deleted original Figure 5 Maximum go gauge of three-phase socket and original Figure 6 Minimum go gauge of three-phase socket; combined them as Figure 6 Three-phase five-wire socket go gauge; - modified original Figure 7 Three-phase socket not-go gauge to Figure 7 Three-phase five-wire socket not-go gauge; - added Figure 8 Three-phase five-wire socket non-contact gauge and its dimensions; - added Figure 9 Three-phase socket live socket contact gauge; - added Figure 10 Schematic diagram of the arrangement facing the three- phase five-wire socket. Three phases plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions 1 Scope This Standard specifies the types, basic parameters and dimensions of three phases plugs and socket-outlets for household and similar purposes. This Standard is applicable to three-phase plugs and three-phase fixed or mobile sockets for household and similar purposes, of which the AC frequency is 50Hz, the rated voltage is 440V, the rated current does not exceed 32A. This Standard does not exclude the use of three-phase plugs and sockets for construction sites, or for agricultural and commercial purposes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1184, Geometrical tolerancing - Geometrical tolerance for features without individual tolerance indications (GB/T 1184-1996, eqv ISO 2768- 2:1989) GB 2099.1-2008, Plugs and socket-outlets for household and similar purposes - Part 1: General requirements (IEC 60884-1:2006, Ed 3.1, MOD) 3 Terms and definitions For the purposes of this document, the terms and definitions defined in GB 2099.1-2008 apply. 4 Technical requirements and test methods The technical requirements and test methods of three-phase plugs and sockets for household and similar purposes shall meet the requirements of GB 2099.1- 2008. 5 Types, basic parameters and dimensions 5.1 The types, basic parameters and dimensions of three-phase plugs and sockets for household and similar purposes shall meet the requirements in Figure 1 to Figure 4. To inspect these dimensions, use the special gauges specified in Figure 5, Figure 6, Figure 7, Figure 8, and Figure 9 and a vernier caliper with a graduation of 0.02mm. The insertion force of the gauge shall not be greater than the maximum extraction force specified in GB 2099.1-2008. The roughness of these gauges are all . The hardness is HRC58~HRC62. The geometric tolerances of the parallelism, perpendicularity and symmetry of the gauge are in accordance with the tolerance level H specified in GB/T 1184. The use methods of special gauges are as follows: - The three-phase plug shall be able to insert the gauge shown in Figure 5; - The universal gauge shown in Figure 6 shall be able to be inserted into the socket of the three-phase five-wire socket panel. For three-phase four- wire sockets, use a go gauge that removes the neutral pole of Figure 6; - The not-go gauge shown in Figure 7 shall not be inserted into the socket of the three-phase five-wire socket panel. For three-phase four-wire sockets, use the not-go gauge that removes the neutral pole of Figure 7; - The non-contact gauge shown in Figure 8 shall not touch the live socket of the socket. For three-phase four-wire sockets, use a non-contact gauge that removes the neutral pole of Figure 8; - The contact gauge shown in Figure 9 shall be able to touch the live socket of the corresponding three-phase socket. 5.2 The positions of the grounding pole and neutral pole of the three-phase socket are arranged as follows: Face the socket. The ground electrode is in the upper position. The neutral pole is in the middle. The arrangement is shown in Figure 10. In addition, the location of the jack shall be clearly marked. 5.3 The shape of the plug is not specified. However, the distance between the plug pin of the live plug and the edge shall not be less than 7.5mm. 5.4 Except for the grounding socket, the distance between the live socket in the three-phase socket and the mating surface shall not be less than the distance specified in Table 1. ......


GB 1003-2008 Three phases plugs and socket-outlets for household and similar purposes.Types, basic parameters and dimensions ICS 29.120.30 K30 National Standards of People's Republic of China Replacing GB 1003-1999 Household and similar three-phase plug and socket Types, basic parameters and dimensions Posted 2008-09-24 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Foreword All the technical contents of this standard is mandatory. This standard replaces and repealing GB 1003-1999 "household and similar purposes-phase plug and socket type, basic parameters and dimensions." The main differences between standard and GB 1003-1999 standard are. --- Chapter 5 increases the insertion force requirements when Gauge inspection; --- Three-phase plug and socket to open the file from the dimensional tolerances effective 3 digits simplified as two digits; --- According to GB 2099.1-2008 the new requirements, the overall modification gauge design tolerances and dimensions; --- Increasing the size of three-phase test socket with the maximum and minimum pass through regulatory compliance. This standard specifies only of household and similar purposes-phase plug and socket type, basic parameters and dimensions, technical requirements and test methods Shall comply with GB 2099.1-2008. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Electric annex Standardization Technical Committee (SAC/TC67) centralized. This standard was drafted. China Electric Apparatus Research Institute, Hangzhou Hongyan Electric Co., Ltd., Shanghai AC electric appliance business associations. The main drafters of this standard. Luohuai Ping, single toward blue, Yangguo Xian, SUN universal. This standard replaces the standards previously issued as follows. --- GB 1003-1980, GB 1003-1999. Household and similar three-phase plug and socket Types, basic parameters and dimensions 1 Scope This standard specifies the type, basic parameters and dimensions of household and similar three-prong plug socket. This standard applies to the family and home environment similar occasions, the AC frequency of 50Hz, rated voltage of 440V, rated current More than 32A three-phase and three-phase plug fixed or mobile sockets. 2 Normative references The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2900.70-2008 Electrotechnical terminology of electrical accessories (IEC 60050-442.1998, IDT) GB 2099.1-2008 plug socket for household and similar purposes - Part 1. General requirements (IEC 60884-1.2006, MOD) GB/T 1184-1996 Note the shape and position tolerances are not specified tolerances (eqv ISO 2768-2. 1989) 3 Terms and Definitions GB/T 2900.70-2008 and GB 2099.1-2008 terms and definitions apply to this standard. 4 technical requirements and test methods Technical requirements and test methods for household and similar purposes shall comply with the three-phase plug and socket GB 2099.1-2008 requirements. 5 Types, basic parameters and dimensions 5.1 Household and similar three-phase plug and socket type, basic parameters and dimensions shall conform to Figure 1, Figure 2 and Table 1, Table 2 is specified. Check These dimensions test use 3 to 7 and special gauge and indexing 3 through 7 of the value of 0.02mm vernier caliper. Plug gauge the amount of Into force should not be greater than the maximum pull-out strength GB 2099.1-2008 requirements. These gauges all roughness, hardness 58HRC ~ 62HRC, gauge parallelism, verticality and symmetry and other geometric tolerances according to GB/T 1184-1996 specified tolerance H-level. 5.2 shape of the plug will not be prescribed. But the plug pin from the edge away from shall ensure compliance with electric shock requirements. Figure 1 Three-phase plug Table 1 Three-phase plug basic parameters and dimensions The main dimensions of the basic parameters of the three-phase plug/mm Rated voltage / Rated current / Open files from the connector pin size 16 9.5 ± 0.11 10.3 ± 0.1410.3 ± 0.14 1.8 0-0.14 8 0-0.22 21 ± 0.42 18 ± 0.35 25 17.5 ± 0.1417.5 ± 0.1417.5 ± 0.14 2.2 0-0.14 12 0-0.27 29 ± 0.42 26 ± 0.42 32 20 ± 0.17 20 ± 0.17 20 ± 0.17 3 0-0.14 15 0-0.27 38 ± 0.50 35 ± 0.50 a plug pin end should be properly rounded chamfer appropriate thickness. Figure 2 Three-phase socket Table 2 Three-phase socket basic parameters and dimensions The main dimensions of the basic parameters of the three-phase socket/mm Rated voltage / Rated current / Open files from the socket jack Dimensions AGFTB 16 9.5 ± 0.11 10.3 ± 0.14 10.3 ± 0.14 2.4 + 0.14 0 9 +0.22 25 17.5 ± 0.14 17.5 ± 0.14 17.5 ± 0.14 3.2 + 0.18 0 13 +0.27 32 20 ± 0.17 20 ± 0.17 20 ± 0.17 4 + 0.18 0 16 +0.27 3-phase plug gauge within Table 3 within a three-prong plug gauge size The basic parameters within the three-prong plug gauge size/mm Rated voltage / Rated current / 0-0.02 0-0.02 9.39 16 10.16 10.16 1.82 0-0.02 0-0.02 0-0.05 9 8.05 25 17.36 0 - 0.02 17.36 0 - 0.02 17.36 0 - 0.02 2.22 0 - 0.02 12.05 0-0.05 9 0-0.02 0-0.02 19.83 19.83 32 19.83 15.05 0-0.05 0-0.02 0-0.02 3.02 12 , B pg 4 three-prong plug external gauge Table 4 three-prong plug external gauge dimensions The basic parameters of the three-phase plug external gauge dimensions/mm Rated voltage / Rated current / + 16 9.61 0.02 0 10.44 +0.02 0 10.44 +0.02 0 1.82 0-0.05 -0.02 8.05 9 25 0.02 0 17.64 17.64 + +0.02 0 17.64 +0.02 0 2.22 12.05 -0.02 0-0.05 9 32 0.02 0 20.17 20.17 + +0.02 0 20.17 +0.02 0 3.02 -0.02 15.05 0-0.05 12 , B pg FIG. 5 through the three-phase socket largest Regulation Table 5 maximum three-phase outlet through regulation size The basic parameters of the three-phase outlet maximum-gauge size/mm Rated voltage / Rated current / Asg Gsg Fsg Tsg Bsg Csga Esga 0-0.02 0-0.02 9.61 16 10.44 10.44 1.8 0-0.02 0-0.02 0-0.05 8 21 0-0.1 180-0. 1 0-0.02 0-0.02 17.64 17.64 25 17.64 2.2 0-0.02 0-0.02 0-0.05 12 29 0-0.1 260-0. 1 0-0.02 32 20.17 20.17 20.17 0-0.02 0-0.02 0-0.02 3 38 15 0-0.05 0-0.1 0-0.1 35 a pin end should be properly rounded chamfer appropriate thickness. FIG. 6 through the three-phase socket minimal regulation Table 6 three-phase outlet pass minimum size regulation The basic parameters of the three-phase outlet pass regulatory minimum size/mm Rated voltage / Rated current / Asg Gsg Fsg Tsg Bsg Csga Esga + 16 9.39 0.02 0 10.16 +0.02 0 10.16 +0.02 0 1.8 8 21 -0.02 0-0.05 0-0.1 0-0.1 18 + 25 17.36 0.02 0 17.36 +0.02 0 17.36 +0.02 0 2.2 12 29 -0.02 0-0.05 0-0.1 0-0.1 26 32 0.02 0 19.83 19.83 + +0.02 0 19.83 +0.02 -0.02 15 0-0.05 38 0-0.1 35 0-0.1 a pin end should be properly rounded chamfer appropriate thickness. Three-phase socket only regulation 7 Table 7-phase socket only regulation size The basic parameters of the three-phase socket only regulation size/mm Rated voltage / Rated current / Asg Gsg Fsg Tsg Bsg Csg Esg 16 9.5 ± 0.02 10.3 ± 0.0210.3 ± 0.02 2.57 0-0.02 9.28 0-0.02 8 8 25 17.5 ± 0.0217.5 ± 0.0217.5 ± 0.02 3.41 0-0.02 13.33 0-0.02 8 8 32 20 ± 0.02 20 ± 0.02 20 ± 0.02 4.21 0-0.02 16.33 0-0.02 8 8 ......

Similar standards: GB 1002-2024  GB/T 1002-2021  
Similar PDFs (Auto-delivered in 9 seconds): GB/T 1003-2016  GB/T 1002-2021  GB 1002-2024  GB/T 2099.1-2021