GB 5413.30-2016 PDF English
US$70.00 · In stock · Download in 9 secondsGB 5413.30-2016: National food safety standard - Determination of Impurities in Milk and Milk Products Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid GB 5413.30: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB 5413.30-2016 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard - Determination of Impurities in Milk and Milk Products
| Valid |
GB 5413.30-2010 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard -- Determination of impurities in milk and milk products
| Obsolete |
GB/T 5413.30-1997 | English | 199 |
Add to Cart
|
2 days
|
Milk and milk powder--Determination of impurities
| Obsolete |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB 5413.30-2016
GB 5413.30-2016: National food safety standard - Determination of Impurities in Milk and Milk Products ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB5413.30-2016
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National Food Safety Standard -
Determination of Impurities in Milk and Milk Products
Issued on. DECEMBER 23, 2016
Implemented on. JUNE 23, 2017
Issued by. National Health and Family Planning Commission of the
People’s Republic of China;
China Food and Drug Administration.
Table of Contents
Foreword... 3
1 Application Scope... 4
2 Principle... 4
3 Reagents and Materials... 4
4 Apparatus... 4
5 Analytical Procedures... 5
6 Expression of Analytical Results... 5
7 Accuracy... 5
Annex A (Normative) Testing of Impurities Filter Plate... 6
Annex B (Normative) Preparation of Impurities Reference Standard Plate... 8
Foreword
This Standard replaces GB 5413.30-2010, National Food Safety Standard –
Determination of Impurities in Milk and Milk Products.
Compared with GB 5413.30-2010, the major changes of this Standard are as follows.
-- the technical requirements for impurities filter plate are added;
-- the testing procedures in Annex A are simplified and the measurement of
impurities loss is modified into the measurement of impurities residuals in the
Annex;
-- the preparation of impurities reference standard plate is modified into the methods
for the preparation of two standard plates for liquid milk and milk powder;
-- the constituents and particle size of impurities are redefined.
National Food Safety Standard -
Determination of Impurities in Milk and Milk Products
1 Application Scope
This Standard specifies the method for the determination of impurities in milk and milk
products.
This Standard applies to the determination of impurities in fresh and raw milk,
pasteurized milk, sterilized milk, condensed milk and milk powder; it does not apply to
the determination of impurities in milk and milk products added with substances which
decrease the efficiency of filter and insoluble coloured matters.
2 Principle
The specimen of fresh and raw milk, liquid milk, water reconstituted milk powder is
filtered through impurities filter plate; the limit of impurities in the specimen is
determined by comparing the visible non-white impurities remaining on the impurities
filter plate with the impurities reference standard plate.
3 Reagents and Materials
Unless stated otherwise, the reagents used in this Method are analytically pure and
the water is grade-3 water as specified in GB/T 6682.
3.1 Impurities filter plate. white cotton plate of diameter 32 mm, mass 135 mg ± 15
mg and thickness 0.8 mm ~ 1.0 mm, which shall be as specified in Annex A. Impurities
filter plate shall be tested in accordance with Annex A.
4 Apparatus
4.1 Balance. sensitivity 0.1 g.
4.2 Filter equipment. impurities filter machine or suction flask, which is capable of
achieving rapid filter by positive pressure or negative pressure (the filter time of each
litre of water is 10 s ~ 15 s).
5 Analytical Procedures
5.1 Preparation of specimen solution
5.1.1 After fully mixing up liquid mild specimen, use a measuring cylinder to measure
500 mL immediately before determination.
5.2 Determination
Place impurities filter plate on the filter equipment, pour the prepared specimen
solution into the funnel of the filter equipment (which shall not overflow from the funnel)
and filter.
6 Expression of Analytical Results
The result obtained by comparing the impurities filter plate after filtering and the
impurities reference standard plate is the degree of impurities in the specimen.
7 Accuracy
For two tests repeated on the same specimen in accordance with the method specified
in this Standard, the results shall be consistent.
Annex A
(Normative)
Testing of Impurities Filter Plate
A.1 Reagents and Materials
A.1.1 Reagents
A.1.2.3 Carob bean gum. biochemical reagent.
A.1.2.4 Sucrose.
A.1.2 Preparation of reagents
A.1.2.1 Methyl alcohol solution (40%). measure 40 mL of methyl alcohol to pour into
a 100-mL volumetric flask, add water dropwise to 100 mL, and filter as standby.
A.1.3 Material
Impurities. use dirt on the floor to dry in a constant temperature drying oven (100°C ±
1°C), use a standard screen to collect dirt constituents of particle size 75 μm ~ 106 μm,
and dry to constant weight.
A.2 Apparatus
A.2.1 Balance. sensitivities 0.1 g and 0.1 mg.
A.2.2 Standard screen.
A.2.3 Desiccator. containing effective desiccant.
A.2.4 Constant temperature drying oven. accuracy ± 1°C.
A.2.5 Filter equipment. as in 4.2.
A.3 Testing procedures
A.4 Evaluation
A.4.1 M = N2 - N1, M shall be ≥ 10 mg. And use a sharp razor blade to cut off the
surface layer of the impurities filter plate and examine the remaining part where no
impurity shall appear.
A.4.2 Test 10 pieces per 1 000 pieces and count as 1 000 pieces if less than 1 000
pieces.
Annex B
(Normative)
Preparation of Impurities Reference Standard Plate
B.1 Reagents and materials
B.1.1 Reagents
B.1.1.1 Arabic gum. biochemical reagent.
B.1.2 Preparation of reagents
B.1.2.1 Arabic gum solution (0.75%). weigh 1.875 g of Arabic gum to pour into a 100-
mL beaker, add 20 mL of water and heat to dissolve, and cool down. Use water to
transfer to a 250-mL volumetric flask and add dropwise to the scale, and filter.
B.1.2.2 Sucrose solution (50%). weigh 1 000 g of sucrose to place into a 1 000-
beaker, add 500 mL of water to dissolve, use water to transfer to a 2 000-mL volumetric
flask and add dropwise to the scale, and filter.
B.1.3 Preparation of materials
B.1.3.1 Cow dung
B.2 Apparatus
B.2.1 Balance. sensitivities 0.1 g and 0.1 mg.
B.2.2 Standard screen.
B.2.3 Filter equipment. as in 4.2.
B.3 Procedures for preparing liquid milk reference standard impurities plate
B.3.1 Preparation of liquid milk impurities reference standard solution
B.3.1.1 Weigh accurately 500.0 mg of cow dung to place into three 100-mL beakers,
namely A, B and C. Add 2 mL of water, add 23 mL of Arabic gum solution, use sucrose
solution to transfer to a 500-mL volumetric flask after mixing up and add dropwise to
the scale, fully mix up until the impurities distributes uniformly, and obtain the cow dung
impurities reference standard solutions of concentration 1.0 mg/mL, namely a0, b0 and
c0.
B.3.2 Preparation of liquid milk reference standard impurities plate
B.3.2.1 Measure 100 mL of sucrose solution, filter on the filter equipment where the
impurities filter plate is mounted, use 100 mL of water of 40°C ± 2°C to wash the filter
plate for several times and dry by airing. Then the impurities plate is the impurities
reference standard plate A1 for the impurities’ relative content in the liquid milk 0 mg/kg.
B.3.2.4 Absorb accurately 18.75 mL of the cow dung impurities reference standard
working solution a2 to pour into a 100-mL volumetric flask, use sucrose solution to
dilute and add dropwise to the scale, filter on the filter equipment where the impurities
filter plate is mounted after mixing up, use water to wash the volumetric flask, and filter
the washings together. Then use 100 mL of water of 40°C ± 2°C to wash the filter plate
for several times, and dry by airing. The impurities plate is the impurities reference
standard plate A4 for the impurities’ relative content in liquid milk 6 mg/8 L.
B.3.3 Use 500 mL of liquid milk as the sampling quantity and see Figure B.1 for the
liquid milk impurities reference standard plates prepared in accordance with Table B.1
– Correlation of Liquid Milk Impurities Reference Standard Plates.
Table B.1 – Correlation of Liquid Milk Impurities Reference Standard Plates
Reference standard plate number A1 A2 A3 A4
Impurities solution
concentration/(mg/mL) 0 0.02 0.02 0.02
Impurities solution volume taken/mL 0 6.25 12.5 18.75
Impurities absolute content/(mg/500
mL) 0 0.125 0.250 0.375
Impurities relative content/(mg/8 L) 0 2 4 6
Figure B.1 – Liquid Milk Impurities Reference Standard Plate
B.4 Procedures for preparing milk powder impurities reference standard plates
B.4.1 Preparation of milk powder impurities reference standard solution
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB 5413.30-2016 be delivered?Answer: The full copy PDF of English version of GB 5413.30-2016 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB 5413.30-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB 5413.30-2016_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 5413.30-2016 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds. Question 5: Should I purchase the latest version GB 5413.30-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 5413.30-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
How to buy and download a true PDF of English version of GB 5413.30-2016?A step-by-step guide to download PDF of GB 5413.30-2016_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB 5413.30-2016". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|