HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB 50325-2020 PDF English

US$560.00 · In stock · Download in 9 seconds
GB 50325-2020: Standard for indoor environmental pollution control of civil building engineering
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB 50325: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 50325-2020English560 Add to Cart 0-9 seconds. Auto-delivery Standard for indoor environmental pollution control of civil building engineering Valid
GB 50325-2010EnglishRFQ ASK 3 days Code for indoor environmental pollution control of civil building engineering Obsolete
GB 50325-2001EnglishRFQ ASK 14 days Code for indoor environmental pollution control of civil building engineering Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 50325-2020
      

Similar standards

GB 50352   GB/T 50378   GB 50343   GB/T 50362   

GB 50325-2020: Standard for indoor environmental pollution control of civil building engineering


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB50325-2020
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA UDC P GB 50325-2020 Standard for indoor environmental pollution control of civil building engineering Issued on. JANUARY 16, 2020 Implemented on. AUGUST 01, 2020 Issued by. Ministry of Housing and Urban-Rural Development of PRC; State Administration for Market Regulation. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Standard for indoor environmental pollution control of civil building engineering Editor-in-Chief. Ministry of Housing and Urban-Rural Development of the People's Republic of China Approved by. Ministry of Housing and Urban-Rural Development of the People's Republic of China Date of implementation. August 1, 2020 China Planning Press 2020 Beijing

Table of Contents

Foreword... 5 1 General provisions... 7 2 Terms and symbols... 8 2.1 Terms... 8 2.2 Symbols... 9 3 Building materials... 10 3.1 Inorganic nonmetallic building materials... 10 3.2 Wood-based panels and finishing products... 10 3.3 Coatings... 11 3.4 Adhesives... 12 3.5 Water-based treatment agents... 13 3.6 Others... 13 4 Survey and designing for building engineering... 16 4.1 General requirements... 16 4.2 Radon concentration measurement and resistance on construction sites... 16 4.3 Choice of construction materials... 18 5 Construction... 20 5.1 General requirements... 20 5.2 On-site examination on building materials... 22 5.3 Requirements for construction... 23 6 Inspection and acceptances... 25 Appendix A Measurement of radon exhalation rate... 30 Appendix B Measurement of content of formaldehyde and VOC emission in decorations materials using environmental test chamber... 33 Appendix C Measurements of radon concentration in soil and radon exhalation rate... 36 Appendix D Measurement of indoor benzene, toluene, xylene... 41 Appendix E Measurement indoor TVOC... 45 Explanation of wording in this standard... 49 List of quoted standards... 50

1 General provisions

1.0.1 This standard is formulated, in order to prevent and control indoor environmental pollution, which is caused by main materials and decoration materials, in civil construction projects; protect public health; safeguard public interests; achieve advanced technology and economical rationality. 1.0.2 This standard is applicable to the control of indoor environmental pollution, in newly constructed, expanded, reconstructed civil construction projects. 1.0.3 The indoor environmental pollutants, which are controlled by this standard, include radon, formaldehyde, ammonia, benzene, toluene, xylene. total volatile organic compounds. 1.0.4 The division of civil construction projects shall meet the following requirements. 1 The category I civil buildings shall include residences, residential functional apartments, hospital wards, elderly care housing facilities, kindergartens, school classrooms, student dormitories, etc.; 2 The category II civil buildings shall include office buildings, shops, hotels, cultural and entertainment venues, bookstores, libraries, exhibition halls, gymnasiums, public transportation waiting rooms, restaurants, etc. 1.0.5 The main building materials and decoration materials, which are selected for civil construction projects, shall comply with the relevant provisions of this standard. 1.0.6 The indoor environmental pollution control of civil buildings shall not only comply with the provisions of this standard, BUT also comply with the relevant current national standards.

2 Terms and symbols

2.1 Terms 2.1.1 Civil building engineering The general term for newly built, expanded, reconstructed civil building structural engineering and decoration engineering. 2.1.2 Environmental test chamber An equipment, which simulates the indoor environment, to test the release of chemical pollutants from decoration materials. 2.1.3 Radon exhalation rate from the surface The radioactive activity of radon, which is released from soil or material surface per unit area and unit time. 2.1.6 Radon concentration The radioactive activity of radon per unit volume of air. 2.1.7 Wood-based panels The panels or formed products, which are produced by using wood or non- wood plant fibers as the main raw material; processing it into various material units; applying (or not applying) adhesives and other additives; gluing together. 2.1.12 Volatile organic compound Under the detection conditions as specified in this standard, the total amount of volatile organic compounds in the measured material, shortly referred to as VOC. 2.1.13 Decorate material loading factor In interior decoration, the ratio of the total exposed area of the decoration materials used TO the net space volume of the room.

3 Building materials

3.1 Inorganic nonmetallic building materials 3.1.1 For inorganic non-metallic main building materials, such as sand, stone, brick, solid block, cement, concrete, concrete prefabricated components, etc. which are used in civil construction projects, the radioactive limit shall comply with the requirements of the current national standard "Limits of radionuclides in building materials" GB 6566. 3.1.4 The measurement method of radionuclides of main materials and decoration materials shall comply with the relevant provisions of the current national standard "Limits of radionuclides in building materials" GB 6566.The measurement method of radon exhalation rate from the surface shall comply with the provisions of Appendix A of this standard. 3.2 Wood-based panels and finishing products 3.2.1 The release of free formaldehyde shall be measured, for the wood-based panels and its products, as used indoors in civil construction projects. 3.3 Coatings 3.3.1 The free formaldehyde limit of indoor water-based decorative panel coatings, water-based wall coatings, water-based wall putty, for civil construction projects shall comply with the current national standard "Limit of harmful substances of architectural wall coatings" GB 18582.

4 Survey and designing for building engineering

4.1 General requirements 4.1.1 For newly-built or expanded civil construction projects, before design, it shall survey the radon concentration in the soil OR the radon exhalation rate from the surface in the urban area, where the construction project is located; 4.1.2 The interior decoration and decoration design of civil buildings shall have pollution control measures. It shall conduct pre-assessment of decoration and decoration design pollution control; control the load ratio of decoration and decoration materials AND the release of material pollutants; adopt advanced technologies such as prefabricated decoration products; the finished products and parts for decorative purposes should be processed in the factory AND installed on site. 4.2 Radon concentration measurement and resistance on construction sites 4.2.1 For the engineering geological survey data of the newly-built and expanded civil construction projects, it shall include the historical measurement data of soil radon concentration or soil radon exhalation rate from the surface AND the average data of soil radon concentration or radon exhalation rate from soil the surface, in the urban area where the project is located. 4.2.4 When the measurement result of radon concentration in the soil of civil construction projects is greater than 20000 Bq/m3 and less than 30000 Bq/m3, OR the radon exhalation rate from the surface is greater than 0.05 Bq/(m2 • s) and less than 0.10 Bq/(m2 • s), it shall take anti-cracking measures at the ground floor of the building. 4.2.5 When the soil radon concentration of the civil construction site is not less than 30000 Bq/m3 and less than 50000 Bq/m3, OR the radon exhalation rate from the surface is not less than 0.10 Bq/(m2 • s) and less than 0.30 Bq/(m2 • s), in addition to taking anti-cracking measures for the ground floor of the building, the foundation must also be treated, according to the grade-1 waterproofing requirements in the current national standard "Technical code for waterproofing of underground works" GB 50108. 4.2.6 When the average radon concentration in the civil construction site 4.3 Choice of construction materials 4.3.1 The radioactive limit of inorganic non-metallic decorative materials, which is used in the interior decoration of the category I civil buildings, must meet the requirements of category A, which is stipulated in the current national standard "Limits of radionuclides in building materials" GB 6566. 4.3.9 In civil construction projects, when the external wall adopts the internal thermal insulation system, it shall select the thermal insulation material with good environmental protection performance; the surface shall be tightly closed; the urea-formaldehyde resin foam material shall not be used as thermal insulation, heat insulation, sound absorbing material.

5 Construction

5.1 General requirements 5.1.1 When materials enter the site, the pollutant release amount or content of the main building materials and decoration materials shall be spot-checked and rechecked, according to the design requirements and the relevant provisions of this standard. 5.1.3 When the main building materials and decoration materials are inspected AND found to be inconsistent with the design requirements and the relevant provisions of this standard, they shall not be used. 5.1.4 The construction organization shall carry out construction, in accordance with the design requirements and the relevant provisions of this standard; it shall not change the requirements of the design documents without authorization. When it needs to be changed, it shall be confirmed by the original design organization, in accordance with the relevant provisions of the construction change procedure. 5.2 On-site examination on building materials 5.2.1 When the inorganic non-metallic main building materials and building decoration materials, which are used in civil construction projects, enter the site, the construction organization shall check the test report of radioactive index. 5.2.8 When the detection items of main building materials and decoration materials are incomplete OR there is doubt about the test results, the materials shall be tested AND can be used only after passing the test. 5.3 Requirements for construction 5.3.1 For civil construction projects, which adopt anti-radon design measures, the construction technology of special parts, such as deformation joints, construction joints, wall-penetrating pipes (boxes), embedded parts, reserved holes, etc. of the underground engineering, shall comply with the relevant provisions of the current national standard "Technical code for waterproofing of underground works" GB 50108. 5.3.6 It is strictly forbidden to use organic solvents to clean construction tools, in the interior decoration of civil buildings. 5.3.7 For civil construction projects in heating areas, interior decoration work should not be carried out, during the heating period. 5.3.8 During the decoration and construction of lightweight partition walls, finishing works, pasting and soft packs, doors and windows, decorative panels, suspended ceilings, etc., attention shall be paid to moisture-proof and avoid covering local wet areas.

6 Inspection and acceptances

6.0.1 The indoor environmental quality acceptance of civil construction projects and interior decoration projects shall be carried out, not less than 7 days after the completion of the project AND before the project is handed over for use. 6.0.2 When the civil construction project is completed and accepted, the following documents shall be checked. 6.0.3 The categories, quantities, construction techniques of the main building materials and decoration materials, which are used in civil construction projects, shall meet the design requirements AND comply with the relevant provisions of this standard. 6.0.8 For the detection of formaldehyde, in the indoor air of civil buildings, it may adopt a simple sampling instrument detection method. 6.0.22 When the detection results of the indoor environmental pollutant concentration do not meet the requirements in Table 6.0.4 of this standard, THEN, for the non-conforming items, it shall double the sampling quantity for detection, which shall include the original unqualified rooms of the same type and the original unqualified rooms. 6.0.23 For civil construction projects, whose detection results of indoor environmental pollutant concentration, do not meet the requirements in Table 6.0.4 of this standard, they are strictly prohibited from being delivered and put into use. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 50325-2020 be delivered?

Answer: The full copy PDF of English version of GB 50325-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 50325-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB 50325-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 50325-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 50325-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 50325-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 50325-2020?

A step-by-step guide to download PDF of GB 50325-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 50325-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9