HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB 5009.15-2023 PDF English

US$140.00 · In stock · Download in 9 seconds
GB 5009.15-2023: National food safety standard - Determination of cadmium in foods
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB 5009.15: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 5009.15-2023English140 Add to Cart 0-9 seconds. Auto-delivery National food safety standard - Determination of cadmium in foods Valid
GB 5009.15-2014English80 Add to Cart 0-9 seconds. Auto-delivery National Food Safety Standard -- Determination of Cadmium in food Obsolete
GB/T 5009.15-2003English399 Add to Cart 3 days Determination of cadmium in foods Obsolete
GB/T 5009.15-1996English279 Add to Cart 3 days Method for determination of cadmium in foods Obsolete
GB 5009.15-1985English199 Add to Cart 2 days Method for determination of cadmium in foods Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 5009.15-2023
      

Similar standards

GB 5009.150   GB 5009.149   GB 5009.148   GB 5009.18   

GB 5009.15-2023: National food safety standard - Determination of cadmium in foods

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB5009.15-2023
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National Food Safety Standard - Determination of Cadmium in Foods Issued on. SEPTEMBER 6, 2023 Implemented on. MARCH 6, 2024 Issued by. National Health Commission of the People’s Republic of China; State Administration for Market Regulation.

Table of Contents

Foreword... 3 1 Scope... 4 Method 1 -- Graphite Furnace Atomic Absorption Spectrometry... 4 2 Principle... 4 3 Reagents and Materials... 4 4 Instruments and Equipment... 5 5 Analytical Procedures... 6 6 Expression of Analysis Results... 8 7 Precision... 9 8 Others... 9 Method 2 - Inductively Coupled Plasma Mass Spectrometry... 9 Appendix A Microwave Digestion Temperature Rise Program and Instrument Reference Conditions of Graphite Furnace Atomic Absorption Spectrometry... 10

Foreword

This Standard serves as a replacement of GB 5009.15-2014 National Food Safety Standard - Determination of Cadmium in Food. In comparison with GB 5009.15-2014, the main changes are as follows. ---Method 2 “inductively coupled plasma mass spectrometry” is added; ---Appendix A “Microwave Digestion Temperature Rise Program and Instrument Reference Conditions of Graphite Furnace Atomic Absorption Spectrometry” is added; ---Specimen preparation is modified; ---The wet digestion method, pressure tank digestion method and microwave digestion method are modified, and the dry digestion method is deleted; ---The matrix modifier for graphite furnace atomic absorption spectrometry is modified. National Food Safety Standard - Determination of Cadmium in Foods

1 Scope

This Standard specifies the method for the determination of cadmium in foods by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. This Standard is applicable to the determination of cadmium in foods. Method 1 -- Graphite Furnace Atomic Absorption Spectrometry

2 Principle

After the specimen is digested, atomize it in a graphite furnace, at 228.8 nm, determine the absorbance. Within a certain concentration range, the absorbance value of cadmium is proportional to the cadmium content. Conduct quantitative comparison with standard series solutions.

3 Reagents and Materials

Unless it is otherwise specified, the reagents used in this Method are all excellent-grade pure, and the water is Grade-2 water specified in GB/T 6682. 3.1 Reagents 3.2 Preparation of Reagents 3.3 Reference Material Cadmium chloride (CdCl2  2.5H2O, CAS No.. 7790-78-5). purity > 99.99%, or a standard substance certified by the state and awarded a reference material certificate. 3.4 Preparation of Standard Solutions 3.4.1 Cadmium standard stock solution (100 mg/L). accurately weigh-take 0.2032 g of cadmium chloride, use a small amount of nitric acid solution (1 + 9) to dissolve it, transfer it into a 1,000 mL volumetric flask. Add water to the scale and evenly mix it. The mass concentration of cadmium in this solution is 100 mg/L. 3.4.2 Cadmium standard intermediate solution (100 g/L). accurately draw 1.00 mL of cadmium standard stock solution (100 mg/L) into a 10 mL volumetric flask, add nitric acid solution (5 + 95) to the scale, and evenly mix it. 3.4.3 Cadmium standard series of working solutions. respectively and accurately draw 0 mL, 0.200 mL, 0.500 mL, 1.00 mL, 2.00 mL and 4.00 mL of cadmium standard intermediate solution (100 g/L) into a 100 mL volumetric flask.

4 Instruments and Equipment

NOTE. all glassware and polytetrafluoroethylene digestion inner tanks need to be soaked in nitric acid solution (1 + 5) overnight, repeatedly rinsed with tap water, and finally, thoroughly rinsed with water. 4.1 Atomic absorption spectrometer. equipped with graphite furnace atomizer and cadmium hollow cathode lamp. 4.2 Electronic balance. with a division value of 0.1 mg and 1 mg.

5 Analytical Procedures

5.1 Specimen Preparation 5.1.1 Solid-state samples 5.1.2 Liquid samples For samples, such as. soft drinks and condiments, etc., evenly shake them. 5.1.3 Semi-solid samples Evenly mix them. 5.2 Test Conditions of the Method 5.2.1 Specimen pre-treatment 5.3 Reference Conditions of Instruments See Table A.2 for instrument operating conditions. 5.4 Drawing of Standard Curve In accordance with the mass concentration from low to high, respectively take 10 L of the standard series of solutions and 5 L of the ammonium dihydrogen phosphate - palladium nitrate mixed solution (select the optimal sample injection volume in accordance with the instrument used), meanwhile, inject it into the graphite tube. 5.5 Determination of Specimen Solution Under the same test conditions as the standard curve, draw 10 L of blank solution or specimen digestion solution, and 5 L of the ammonium dihydrogen phosphate - palladium nitrate mixed solution (select the optimal sample injection volume in accordance with the instrument used), meanwhile, inject it into the graphite tube.

6 Expression of Analysis Results

The content of cadmium in the specimen is calculated in accordance with Formula (1).

7 Precision

When the cadmium content in the specimen is > 1 mg/kg (mg/L), the absolute difference between the results of two independent determinations obtained under repeatability conditions shall not exceed 10% of the arithmetic mean.

8 Others

When the sampling size is 0.5 g or 2 mL and the constant volume is 10 mL, the detection limit of this Method is 0.002 mg/kg or 0.0005 mg/L, and the quantitation limit is 0.004 mg/kg or 0.001 mg/L.

Appendix A

Microwave Digestion Temperature Rise Program and Instrument Reference Conditions of Graphite Furnace Atomic Absorption Spectrometry A.1 The microwave digestion temperature rise program is shown in Table A.1. Table A.1 -- Microwave Digestion Temperature Rise Program ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 5009.15-2023 be delivered?

Answer: The full copy PDF of English version of GB 5009.15-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 5009.15-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB 5009.15-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 5009.15-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB 5009.15-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 5009.15-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB 5009.15-2023?

A step-by-step guide to download PDF of GB 5009.15-2023_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 5009.15-2023".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.