GB 32049-2015English115 Add to Cart 0--9 seconds. Auto-delivery Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans Valid GB 32049-2015


BASIC DATA
Standard ID GB 32049-2015 (GB32049-2015)
Description (Translated English) Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans
Sector / Industry National Standard
Classification of Chinese Standard F01
Classification of International Standard 27.010
Word Count Estimation 7,757
Date of Issue 2015-09-18
Date of Implementation 2016-10-01
Quoted Standard GB/T 1236; GB/T 2828.1; GB/T 2829; GB/T 14806
Drafting Organization China National Institute of Standardization; Guangdong is wild Electric Co., Ltd.; Guangdong Midea Electric Manufacturing Co. environment; Guangdong Green Wind Technology Co., indoor air system; Guangzhou Institute of Technology CVC detection; Jiangmen Jinling Fan Manufacturing Co.; one hundred buildings Lang electrical supplies (Huizhou) Co., Ltd; Airmate electrical (Shenzhen) Co., Ltd; Panasonic Ecology systems Guangdong Co., Ltd.; Jiangmen Jinling Pai Qishan manufacturing Co., Ltd.; China quality certification Center
Administrative Organization National Energy Foundation and Management Standardization Technical Committee (SAC/TC 20)
Regulation (derived from) National Standard Announcement 2015 No.28
Proposing organization Ministry of Industry and Information Technology Energy Saving and Comprehensive Utilization Department; National Development and Reform Commission Resource Conservation and Environmental Protection
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Standard specifies the ventilator exchange for household and similar purposes (hereinafter referred to as ventilator) energy efficiency limit value and energy efficiency rating, energy conservation evaluation values, test methods, inspection rules and energy efficiency rating label. This Standard applies to single-phase rated voltage not exceeding 250 V, rated input power less than 500 W, an impeller diameter of not more than 500 mm, by an AC motor driven fan. This Standard does not apply to the following uses of fan: a) specifically designed for industrial use ventilating fans; b) intended to be used under special conditions, such as corrosive, flammable and explosive gases, dust, steam or gas present in place ventilation fans; c) for air-heater, air conditioner or refrigeration equipment and air-air energy recovery ventilator used; d) embedded appliances (such as stoves and microwave cooking appliance) ventilator; e) marine fan; f) C-type fan, bidirectional wind ventilator, and B and D is less than the maximum static pressure of 25 Pa ventilator.


GB/T 32049-2015 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.010 F 01 Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans ISSUED ON: SEPTEMBER 18, 2015 IMPLEMENTED ON: OCTOBER 01, 2016 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Technical requirements ... 5  5 Test method ... 8  6 Inspection rules ... 9  7 Energy efficiency grade marking ... 9  Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans 1 Scope This Standard specifies the minimum allowable values, energy efficiency grades, evaluating values of energy conservation, test methods, inspection rules and energy efficiency grade marking for household and similar purposes A.C. electric ventilating fans (hereinafter referred to as ventilating fans). This Standard is applicable to AC motor-driven ventilating fans, of which the single-phase rated voltage is not more than 250 V, the rated input power not more than 500 W, and the impeller diameter is not more than 500 mm. This Standard does not apply to ventilating fans for the following purposes: a) ventilating fans that are specially designed for industrial use; b) ventilating fans that are intended for use in special conditions, such as places where there are corrosive, flammable, explosive gases, dust, steam or coal gas; c) ventilating fans for air heaters, freezers or air conditioners and air-to-air energy recovery devices; d) ventilating fans that are embedded in appliances such as stoves and microwave cooking appliances; e) marine ventilating fans; f) type-C ventilating fans, two-way air-out fans, and type-B and type-D ventilating fans of which the maximum static pressure is less than 25 Pa. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1236, Industrial fan. Performance testing using standardized airways GB/T 2828.1, Sampling procedures for inspection by attributes. Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 2829, Sampling procedures and tables for periodic inspection by attributes (apply to inspection of process stability) GB/T 14806, A.C. electric ventilating fans and regulators for household and similar purposes 3 Terms and definitions Terms and definitions determined by GB/T 14806 and the following ones are applicable to this document. 3.1 Energy efficiency values for ventilating fans Under the standard test conditions, the ratio of the measured air volume of the ventilating fan to the measured input power of the fan blade drive motor, in cubic meters per watt [m3/(min·W)]. 3.2 Minimum allowable values of energy efficiency for ventilating fans The minimum energy efficiency value for ventilating fans that is allowed under the standard test conditions, in cubic meters per watt [m3/(min·W)]. 3.3 Reach minimum allowable values of energy efficiency for ventilating fans The minimum allowable values of energy efficiency for ventilating fans that is implemented after several years of implementation of this Standard. 3.4 Evaluating values of energy conservation for ventilating fans The minimum energy efficiency index that an energy-conservation ventilating fan shall achieve under standard test conditions, in cubic meters per watt [m3/(min·W)]. 4 Technical requirements 4.1 Basic requirements The performance of the ventilating fans to which this Standard applies shall comply with the requirements of GB/T 14806. 4.2 Energy efficiency grades for ventilating fans requirements in GB/T 1236. If there is any dispute over the test results, test and determine according to the method that is specified in GB/T 1236. 6 Inspection rules 6.1 Delivery inspection 6.1.1 The inspection plan which refers to GB/T 2828.1 and GB/T 2829, shall be carried out by the manufacturer's quality inspection department in accordance with relevant enterprise standards. 6.1.2 Products whose energy efficiency values are recognized, through inspection, to be inconsistent with the requirements of 4.3 are not allowed to be delivered. 6.2 Type inspection 6.2.1 When any of the following conditions occurs, the type inspection of minimum allowable values shall be carried out: a) new products that are trial-produced; b) when the product design, process or used materials are changed to significantly affect its performance; c) when inspection requirements are put forward by the quality and technical supervision department. 6.2.2 For sampling of type inspection, 3 machines shall be sampled at a time, one for testing and two for standby application. If the test result does not meet the specified requirements, test the two standby samples; the measured values shall meet the specified requirements; otherwise, the batch of products shall be judged as unqualified. 7 Energy efficiency grade marking 7.1 The manufacturer shall determine the rated energy efficiency grades of the product in accordance with the requirements of this Standard and the test results. 7.2 The manufacturer shall indicate the rated energy efficiency grade of the product and the standard number on which it is based on the product documentation of its product. __________ END __________ ......