Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Aug 8, 2020)
HOME  COVID-19   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB 27948-2011

Chinese Standard: 'GB 27948-2011'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB 27948-2011English100 Add to Cart 0--10 minutes. Auto immediate delivery. Hygienic requirements for air disinfectant Valid GB 27948-2011
GB 27948-2011Chinese14 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID GB 27948-2011 (GB27948-2011)
Description (Translated English) Hygienic requirements for air disinfectant
Sector / Industry National Standard
Classification of Chinese Standard C59
Classification of International Standard 11.080
Word Count Estimation 6,669
Date of Issue 2011-12-30
Date of Implementation 2012-05-01
Quoted Standard GB 1616; GB 19104; disinfection technical specifications Ministry of Health, 2002; disinfection product label instructions management practices Ministry of Health 2005
Drafting Organization PLA Disease Control and Prevention
Administrative Organization Ministry of Health
Regulation (derived from) Announcement of Newly Approved National Standards No. 23 of 2011
Proposing organization People's Republic of China Ministry of Health
Issuing agency(ies) Ministry of Health of People's Republic of China; Standardization Administration of China
Summary This Chinese standard relates to indoor air disinfection common technical requirements disinfectant to kill microbiological requirements, security requirements, and to use, test methods, labels and instructions, use precautions. This standard applies to kill microorganisms in the air for the purpose, and can achieve disinfection requirements for indoor air disinfectant. This standard does not apply to indoor surface disinfection in order to achieve the purpose, both air disinfection disinfectant.

GB 27948-2011
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 11.080
C 59
Hygienic Requirements for Air Disinfectant
空气消毒剂卫生要求
ISSUED ON: DECEMBER 30, 2011
IMPLEMENTED ON: MAY 01, 2012
Issued by: Ministry of Health of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Technical Requirements for Common Disinfectants ... 5
5 Test Methods ... 6
6 Use Methods ... 6
7 Labels and Instructions ... 7
8 Precautions for Use ... 7
Hygienic Requirements for Air Disinfectant
1 Scope
This Standard specifies the technical requirements, killing microorganism
requirements, safety requirements, use, test methods, labels and instruction manual,
and precautions for common disinfectants used for indoor air disinfection.
This Standard is applicable to indoor air disinfectants for the purpose of killing
microorganisms in the air, and can meet the requirements of disinfection.
This Standard is not applicable to disinfectants for the purpose of the disinfection of
objects in the laboratory, and have the function of air disinfection.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) are applicable to this document.
GB 1616 Hydrogen Peroxide for Industrial Use
GB 19104 Peracetic Acid Solution
Technical Standard for Disinfection (2002); Ministry of Health
Management Practices for Label and Instruction Book of Disinfection Products
(2005); Ministry of Health
3 Terms and Definitions
For the purposes of this document, the following terms and definitions apply.
3.1 Air disinfection
Use disinfectant to kill pathogenic microorganisms suspended in the air in the closed
room, so as to achieve harmless treatment.
3.2 Air disinfectant
Formulation for killing pathogenic microorganisms in the air to achieve disinfection
requirements.
3.3 Aerosol sprayer
The sprayer that may occur the atomized particle diameter range below 50μm, of which
the atomized particles whose diameter is less than 20μm account for more than 90%,
and the spray flow rate is above 100mL/min.
3.4 Fumigation disinfection
Use the disinfectant gas to kill pathogenic microorganisms in closed spaces, so as to
achieve harmless treatment.
4 Technical Requirements for Common Disinfectants
4.1 Requirements of physical and chemical indicator
4.1.1 The physical and chemical indicators such as the content of active ingredients of
disinfectant, pH value, etc. shall satisfy the relevant standards of product quality.
Peracetic acid shall meet the requirements of GB 19104; while hydrogen peroxide shall
meet the requirements of GB 1616.
4.1.2 Stability requirements: the decline rate of effective composition for the liquid
disinfectant during the effective period of the product shall be ≤15%; the decline rate
of effective composition content for the solid disinfectant during the effective period of
the product shall be ≤10%.
4.1.3 Residues after disinfection and residual toxicity in the environment shall meet the
requirements of relevant national standards and regulations.
4.1.4 During the disinfection process, combustion and explosion are not easy to occur.
4.2 Requirements for killing microorganisms
4.2.1 In the laboratory sterilization test or disinfection simulation field test, when using
aerosol spray method for disinfection, the dosage of disinfectan......
Related standard:   GB 27948-2020  GB 27949-2020
Related PDF sample:   GB 27948-2020  GB 27949-2020
   
 