GB 24500-2009_English: PDF (GB24500-2009)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB 24500-2020 | English | 95 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
Minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers
| Valid |
GB 24500-2020
|
GB 24500-2009 | English | 70 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
The minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers
| Obsolete |
GB 24500-2009
|
Preview PDF: GB 24500-2020 Standards related to: GB 24500-2009
Standard ID | GB 24500-2009 (GB24500-2009) | Description (Translated English) | The minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers | Sector / Industry | National Standard | Classification of Chinese Standard | F04 | Classification of International Standard | 27.060 | Word Count Estimation | 8,815 | Date of Issue | 2009-10-30 | Date of Implementation | 2010-09-01 | Quoted Standard | GB/T 2900.48; GB/T 10180; JB/T 10094 | Drafting Organization | China National Institute of Standardization | Administrative Organization | National Energy Foundation and Management Standardization Technical Committee | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2009 (No. 152 overall) | Proposing organization | National Development and Reform Commission | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This Chinese standard specifies the level of energy efficiency of industrial boilers, energy efficiency limit values ??and test methods for evaluating values ??of energy conservation. This standard applies to coal, oil, gas as fuel, rated steam pressure greater than 0. 04MPa, but smaller than 3. 8MPa, and the rated capacity of not less than 0. 1t/h of water as the medium of stationary steam boilers and steel rated water pressure is greater than 0. 1 MPa steel boiler fixed. |
GB 24500-2009
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 27.060
F 04
The Minimum Allowable Values of Energy Efficiency
and Energy Efficiency Grades Industrial Boilers
ISSUED ON. OCTOBER 30, 2009
IMPLEMENTED ON. SEPTEMBER 01, 2010
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Technical Requirements ... 5
4.1 Basic Requirements ... 5
4.2 Energy Efficiency Grades of Industrial Boilers ... 5
4.3 Minimum Allowable Values of Energy Efficiency of Industrial Boilers. 5
4.4 Evaluating Values of Energy Conservation of Industrial Boilers ... 5
5 Test Methods ... 5
Foreword
Article 4.3 in this standard is mandatory; and others are recommendatory.
This standard was proposed by the National Development and Reform Commission.
This standard shall be under the jurisdiction of National Technical Committee on
Energy Fundamentals and Management of Standardization Administration of China.
Drafting organizations of this standard. China National Institute of Standardization,
Shanghai Industrial Boiler Research Institute, Boiler Institute of Xi'an Jiaotong
University, Guangzhou Tianlu Boiler Co., Ltd., Jiangsu Taihu Boiler Co., Ltd. and
Shandong Huayuan Boiler Co., Ltd.
Chief drafting staffs of this standard. Zhang Xin, Qian Fenghua, Zhao Yuejin, Zhao
Qinxin, Xi Daiguo, Pu Jianhong, Fu Guangtian, Jia Tieying and Xin Sheng.
The Minimum Allowable Values of Energy Efficiency
and Energy Efficiency Grades Industrial Boilers
1 Scope
This standard specifies the energy efficiency grades, minimum allowable values of
energy efficiency, evaluating values of energy conservation and test methods of
industrial boilers.
This standard is applicable to stationary steel steam boilers that the fuel is coal, oil
and gas, the rated steam pressure is larger than 0.04MPa but less than 3.8MPa, the
rated steam output is not less than 0.1 t/h and the medium is water and stationary
steel hot water boilers that the rated water outlet pressure is larger than 0.1MPa.
2 Normative References
The following standards contain the provisions which, through reference in this text,
constitute the provisions of this standard. For dated reference, the subsequent
modification or revisions of these publications do not apply. However, all parties who
reach an agreement according to this standard are encouraged to study whether the
latest edition of these documents is applicable. For undated references, the latest
edition of the normative document is applicable to this standard.
GB/T 2900.48 Electrotechnical Terminology of Boilers
GB/T 10180 Thermal Performance Test Code for Industrial Boilers
JB/T 10094 General Specification for Industrial Boilers
3 Terms and Definitions
Terms and definitions established by GB/T 2900.48 and the following ones are
applicable to this standard.
3.1
The minimum allowable values of energy efficiency of industrial boilers
It refers to the minimum allowable thermal efficiency values of industrial boilers under
rated condition under test conditions specified in the standard.
3.2
The evaluating values of energy conservation of industrial boilers
It refers to the minimum thermal efficiency values for evaluating energy conservation
products of industrial boiler under rated condition under test conditions specified in the
standard.
4 Technical Requirements
4.1 Basic Requirements
The technical requirements of industrial boilers applicable to this standard shall meet
the requirements of JB/T 10094 and relevant standards.
4.2 Energy Efficiency Grades of Industrial Boilers
The energy efficiency grades of industrial boilers are divided into 3 grades, and Grade
1 is the highest. The thermal efficiency values of each grade industrial boiler under
rated condition shall not be less than those specified in Table 1 ~ Table 4.
4.3 Minimum Allowable Values of Energy Efficiency of Industrial Boilers
The thermal efficiency values of industrial boilers under rated condition shall not be
less than the specification for Grade 3 in Table 1 ~ Table 4.
4.4 Evaluating Values of Energy Conservation of Industrial Boilers
The thermal efficiency values of industrial boilers under rated condition shall not be
less than the specification for Grade 2 in Table 1 ~ Table 4.
5 Test Methods
The thermal efficiency values of industrial boilers shall be tested according to those
specified in GB/T 10180.
......
|