HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (30 Nov 2024)

GB 24500-2009 English PDF (GB 24500-2020 Newer Version)

GB 24500-2009_English: PDF (GB24500-2009)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 24500-2020English95 Add to Cart 0--9 seconds. Auto-delivery Minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers Valid GB 24500-2020
GB 24500-2009English70 Add to Cart 0--9 seconds. Auto-delivery The minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers Obsolete GB 24500-2009
Preview PDF: GB 24500-2020    Standards related to: GB 24500-2009

BASIC DATA
Standard ID GB 24500-2009 (GB24500-2009)
Description (Translated English) The minimum allowable values of energy efficiency and energy efficiency grades of industrial boilers
Sector / Industry National Standard
Classification of Chinese Standard F04
Classification of International Standard 27.060
Word Count Estimation 8,815
Date of Issue 2009-10-30
Date of Implementation 2010-09-01
Quoted Standard GB/T 2900.48; GB/T 10180; JB/T 10094
Drafting Organization China National Institute of Standardization
Administrative Organization National Energy Foundation and Management Standardization Technical Committee
Regulation (derived from) Announcement of Newly Approved National Standards No. 12 of 2009 (No. 152 overall)
Proposing organization National Development and Reform Commission
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard specifies the level of energy efficiency of industrial boilers, energy efficiency limit values ??and test methods for evaluating values ??of energy conservation. This standard applies to coal, oil, gas as fuel, rated steam pressure greater than 0. 04MPa, but smaller than 3. 8MPa, and the rated capacity of not less than 0. 1t/h of water as the medium of stationary steam boilers and steel rated water pressure is greater than 0. 1 MPa steel boiler fixed.


GB 24500-2009 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.060 F 04 The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Industrial Boilers ISSUED ON. OCTOBER 30, 2009 IMPLEMENTED ON. SEPTEMBER 01, 2010 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 4  4 Technical Requirements ... 5  4.1 Basic Requirements ... 5  4.2 Energy Efficiency Grades of Industrial Boilers ... 5  4.3 Minimum Allowable Values of Energy Efficiency of Industrial Boilers. 5  4.4 Evaluating Values of Energy Conservation of Industrial Boilers ... 5  5 Test Methods ... 5  Foreword Article 4.3 in this standard is mandatory; and others are recommendatory. This standard was proposed by the National Development and Reform Commission. This standard shall be under the jurisdiction of National Technical Committee on Energy Fundamentals and Management of Standardization Administration of China. Drafting organizations of this standard. China National Institute of Standardization, Shanghai Industrial Boiler Research Institute, Boiler Institute of Xi'an Jiaotong University, Guangzhou Tianlu Boiler Co., Ltd., Jiangsu Taihu Boiler Co., Ltd. and Shandong Huayuan Boiler Co., Ltd. Chief drafting staffs of this standard. Zhang Xin, Qian Fenghua, Zhao Yuejin, Zhao Qinxin, Xi Daiguo, Pu Jianhong, Fu Guangtian, Jia Tieying and Xin Sheng. The Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades Industrial Boilers 1 Scope This standard specifies the energy efficiency grades, minimum allowable values of energy efficiency, evaluating values of energy conservation and test methods of industrial boilers. This standard is applicable to stationary steel steam boilers that the fuel is coal, oil and gas, the rated steam pressure is larger than 0.04MPa but less than 3.8MPa, the rated steam output is not less than 0.1 t/h and the medium is water and stationary steel hot water boilers that the rated water outlet pressure is larger than 0.1MPa. 2 Normative References The following standards contain the provisions which, through reference in this text, constitute the provisions of this standard. For dated reference, the subsequent modification or revisions of these publications do not apply. However, all parties who reach an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard. GB/T 2900.48 Electrotechnical Terminology of Boilers GB/T 10180 Thermal Performance Test Code for Industrial Boilers JB/T 10094 General Specification for Industrial Boilers 3 Terms and Definitions Terms and definitions established by GB/T 2900.48 and the following ones are applicable to this standard. 3.1 The minimum allowable values of energy efficiency of industrial boilers It refers to the minimum allowable thermal efficiency values of industrial boilers under rated condition under test conditions specified in the standard. 3.2 The evaluating values of energy conservation of industrial boilers It refers to the minimum thermal efficiency values for evaluating energy conservation products of industrial boiler under rated condition under test conditions specified in the standard. 4 Technical Requirements 4.1 Basic Requirements The technical requirements of industrial boilers applicable to this standard shall meet the requirements of JB/T 10094 and relevant standards. 4.2 Energy Efficiency Grades of Industrial Boilers The energy efficiency grades of industrial boilers are divided into 3 grades, and Grade 1 is the highest. The thermal efficiency values of each grade industrial boiler under rated condition shall not be less than those specified in Table 1 ~ Table 4. 4.3 Minimum Allowable Values of Energy Efficiency of Industrial Boilers The thermal efficiency values of industrial boilers under rated condition shall not be less than the specification for Grade 3 in Table 1 ~ Table 4. 4.4 Evaluating Values of Energy Conservation of Industrial Boilers The thermal efficiency values of industrial boilers under rated condition shall not be less than the specification for Grade 2 in Table 1 ~ Table 4. 5 Test Methods The thermal efficiency values of industrial boilers shall be tested according to those specified in GB/T 10180. ......