YY/T 1780-2021: (Medical personal protection system)
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 1780-2021339 Add to Cart 3 days (Medical personal protection system) Valid

Similar standards

YY/T 1633   YY/T 1642   YY/T 1632   YY/T 1947   YY/T 1117   

Basic data

Standard ID: YY/T 1780-2021 (YY/T1780-2021)
Description (Translated English): (Medical personal protection system)
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C48
Word Count Estimation: 16,110
Issuing agency(ies): State Drug Administration

YY/T 1780-2021: (Medical personal protection system)

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Medical personal protection system) ICS 11.140 C48 People's Republic of China Pharmaceutical Industry Standard Medical Personal Protection System Published on 2021-09-06 2023-09-01 Implementation Released by the State Drug Administration

foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some content of this document may be patented. Publication of this document Institutions do not assume responsibility for identifying these patents. This standard is proposed by the State Drug Administration. This standard is under the jurisdiction of Beijing Medical Device Inspection Institute. This standard was drafted by. Beijing Medical Device Inspection Institute, Beijing Zhongke Shengkang Technology Co., Ltd., Beijing Medical Device Technology Review center. The main drafters of this standard. Yue Weihua, Jiang Leyang, Liu Simin, Ma Li, Zhao Dan, Zhang Yaping, Liang Zhenshi, Meng Zhiping, Chen Ran, Wang Chen, Li Jian, Hu Guangyong. Medical Personal Protection System

1 Scope

This standard specifies the composition and structure, requirements, test methods, signs and use of medical personal protective systems (hereinafter referred to as protective systems). Instructions, packaging, transportation, storage. This standard is applicable to the operating room, in the invasive operating environment, in order to prevent potentially infectious body fluids, microorganisms and particulate matter from affecting the A medical personal protective system that provides isolation and protection from splashes on the body, head and face of medical staff in the operating room. This standard does not apply to positive or negative pressure tight medical personal protective systems.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191-2008 Graphical signs of packaging, storage and transportation GB/T 2410-2008 Determination of transmittance and haze of transparent plastics GB 4793.1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1.General Requirements GB 4943.1 Information Technology Equipment Safety Part 1.General Requirements GB 9706.1 Medical Electrical Equipment Part 1.General Requirements for Basic Safety and Essential Performance GB/T 14710-2009 Environmental requirements and test methods for medical electrical appliances GB/T 16886.1 Biological Evaluation of Medical Devices Part 1.Evaluation and Testing in Risk Management Process GB/T 18268.1 Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1.General Requirements GB 19082-2009 Technical requirements for medical disposable protective clothing GB/T 23315-2009 Velcro YY 0505 Medical Electrical Equipment Part 1-2.Parallel Standard for General Requirements for Safety. Electromagnetic Compatibility Requirements and Tests YY/T 0506.2-2016 Surgical drapes, gowns and clean suits for patients, medical staff and instruments - Part 2.Performance requirements and experiment method YY/T 1499-2016 Liquid barrier properties and classification of medical protective clothing Pharmacopoeia of the People's Republic of China (four volumes of the 2020 edition)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 It consists of a helmet, a helmet air supply system, a disposable hood, a disposable protective clothing, etc. It is worn by the operating room personnel to prevent blood loss. Isolation protection system used in combination for the splashing and combined use of liquid, body fluids, powders and other pollutants on the body, head and face of the operating room personnel. 3.2 protective clothingprotectiveclothing As the body protection component of the medical personal protection system, it is used for medical personnel to contact potentially infectious patient body fluids, microbes during work.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1780-2021_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1780-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1780-2021_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1780-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.