YY/T 1772-2021 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 1772-2021: Implants for surgery - Standard test method for conducting and evaluating galvanic corrosion tests in electrolytes Status: Valid
Basic dataStandard ID: YY/T 1772-2021 (YY/T1772-2021)Description (Translated English): Implants for surgery - Standard test method for conducting and evaluating galvanic corrosion tests in electrolytes Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C35 Word Count Estimation: 12,159 Issuing agency(ies): State Drug Administration YY/T 1772-2021: Implants for surgery - Standard test method for conducting and evaluating galvanic corrosion tests in electrolytes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Implants for surgery - Standard test method for conducting and evaluating galvanic corrosion tests in electrolytes ICS 11.040.40 C35 People's Republic of China Pharmaceutical Industry Standards Test method for galvanic corrosion in the electrolyte of surgical implants Released on 2021-03-09 2022-04-01 implementation Issued by the National Medical Products Administration Table of contentsForeword Ⅲ 1 Scope 1 2 Normative references 1 3 Significance and application 1 4 Instrument 1 5 Test sample 2 6 Test environment 4 7 Test Step 4 8 Evaluation of the sample 5 9 Report 5 Appendix A (informative appendix) Typical test electrolytic cell 6 Appendix B (Informative Appendix) Basic Principle 7 Reference 9ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of the National Standardization Technical Committee for Surgical Implants and Orthopaedic Devices (SAC/TC110). Drafting organizations of this standard. Tianjin Medical Device Quality Supervision and Inspection Center, Medical Device Technology Review under the State Drug Administration Xin, Jiangyin Fasten Peer New Material Technology Co., Ltd., National Standard (Beijing) Inspection and Certification Co., Ltd. The main drafters of this standard. Jiang Xi, Li Wenjiao, Zhang Jiazhen, Aruhan, Chen Qingfu, Wang Lingling, Zhang Wenmei, Fan Zhigang. Test method for galvanic corrosion in the electrolyte of surgical implants1 ScopeThis standard provides the galvanic corrosion test and evaluation methods for surgical implants, covering sample selection, sample preparation, test environment, and exposure methods. Formula and characterization of the evaluation method of the test results of the corrosion behavior of the galvanic couple in the electrolyte. This standard is applicable to characterize the electrical contact state of two or more different metals applied to the human body as surgical implants or parts thereof Corrosion behavior. This standard does not apply to the evaluation of other forms of corrosion and degradation of surgical implants. This standard also does not apply to the evaluation surface Change of state. Note 1.The types of devices that may need to be evaluated include overlapping brackets of different alloys, combinations of brackets and bracket markers, and one or more screws in bone plates and screws. The nail and the rest of the device belong to a combination of different alloys, a multi-component structure made of two or more alloys. For those partially implanted but Devices that have long-term contact with the human body (such as external fixation devices) can also be evaluated using this standard. Note 2.The effects of other forms of corrosion and degradation of equipment include but are not limited to the following conditions. such as fretting corrosion, crevice corrosion, and any galvanic corrosion on stress The influence of corrosion and corrosion fatigue, etc. Note 3.The surface state changes include but are not limited to the following conditions. such as (may be caused by the implantation process) scratches or (during the manufacturing process) welding effects.2 Normative referencesThe following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 6682 Analytical laboratory water specifications and test methods YY/T 0695-2008 Standard Test Method for Cyclic Potential Polarization of Corrosion Sensitivity of Small Implanted Devices YY/T 1552 Surgical Implant Evaluation Method of Open Circuit Potential Measurement for the Long-term Corrosion Behavior of Metal Implant Materials and Medical Devices3 Significance and application3.1 Implantable medical devices can be made of different metals, and can also be in electrical contact with different metals, causing galvanic corrosion. This can lead to the release of corrosion products, which can trigger harmful biological reactions or sacrifice the structural integrity of the device. So measure these plantable The galvanic corrosion susceptibility of the imported device is very important. 3.2 The use of this test method is to provide information on the galvanic components that corrode when two different metals are in contact with each other. Different gold in contact with each other The genus can be on the same implant device, or it can be an independent implant device component. 3.3 This test method is designed to adapt to various device shapes and sizes by using a variety of fixtures. 3.4 This standard is a test method for galvanic corrosion test under simulated physiological environment. Strictly following this test method helps to avoid this Some inherent confusion in class testing.4 Instruments4.1 Potentiostat 4.1.1 A high-impedance potentiostat that can be connected to a zero-resistance ammeter (ZRA). ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1772-2021_English be delivered?Answer: Upon your order, we will start to translate YY/T 1772-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 1772-2021_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1772-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |