YY/T 1766.4-2024: Image quality evaluation methods for computed tomography system - Part 4: Imaging performance under automatic exposure control
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 1766.4-2024479 Add to Cart 4 days Image quality evaluation methods for computed tomography system - Part 4: Imaging performance under automatic exposure control Valid

Similar standards

YY/T 1694   YY/T 1711   YY/T 1537   YY/T 1766.3   YY/T 1766.2   YY/T 1757   

Basic data

Standard ID: YY/T 1766.4-2024 (YY/T1766.4-2024)
Description (Translated English): Image quality evaluation methods for computed tomography system - Part 4: Imaging performance under automatic exposure control
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 23,227
Date of Issue: 2024-02-07
Date of Implementation: 2025-09-01
Issuing agency(ies): State Drug Administration
Summary: This standard specifies the corresponding imaging performance evaluation method when X-ray computed tomography equipment (hereinafter referred to as CT scanning device) adopts automatic exposure control technology. This document applies to whole-body and specialized CT scanning devices, including CT scanning devices that provide image data for radiation therapy planning.

YY/T 1766.4-2024: Image quality evaluation methods for computed tomography system - Part 4: Imaging performance under automatic exposure control


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11.040.50 CCSC43 Pharmaceutical Industry Standards of the People's Republic of China X-ray computed tomography image Quality assessment methods Part 4.Automatic exposure Evaluation of imaging performance under control Released on 2024-02-07 2025-09-01 Implementation The State Drug Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Imaging conditions related to CT automatic exposure control 2 5 Imaging performance evaluation method under X-ray tube current modulation 2 6 Performance Evaluation of Automatic Exposure Control 8 Appendix A (Informative) Implementation of Tube Current Modulation Technology 10 Appendix B (Informative) Image performance evaluation under X-ray tube current modulation 14 Reference 17

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is part 4 of YY/T 1766 "Image quality evaluation method for X-ray computed tomography equipment". The following parts have been published. --- Part 1.Evaluation of modulation transfer function; --- Part 2.Evaluation of low contrast resolution; --- Part 3.Performance evaluation of dual energy imaging and energy spectrum application; --- Part 4.Evaluation of imaging performance under automatic exposure control. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by the State Food and Drug Administration. This document is provided by the National Technical Committee for Standardization of Medical Electrical Appliances - Medical X-ray Equipment and Appliances Sub-Technical Committee (SAC/TC10/SC1) Centralized. This document was drafted by. Shanghai Siemens Medical Devices Co., Ltd., Liaoning Medical Device Inspection and Testing Institute, Shanghai United Imaging Medical Technology Co., Ltd., Hangwei General Electric Medical Systems Co., Ltd., Neusoft Medical Systems Co., Ltd., Philips Healthcare (Suzhou) Co., Ltd. Company, Mingfeng Medical Systems Co., Ltd., and Kuanteng (Beijing) Medical Equipment Co., Ltd. The main drafters of this document are. Tian Yi, Sun Zhiyong, Cai Xiaolu, Zhou Pei, Wei Dong, Liang Tiecheng, He Xiujian, Lu Xiaodong, Tong Zhiyuan, Xu Yifei, Xing Zhanfeng, Chen Wei, Xiang Huicai, and Li Xiang.

Introduction

YY/T 1766 is a method standard system for evaluating the image quality of CT scanning devices, which aims to establish relevant image performance and imaging methods. The standardized evaluation method for environmental protection is composed of the following four parts. --- Part 1.Modulation transfer function evaluation. The purpose is to establish an evaluation method for the spatial imaging resolution of CT scanning devices. --- Part 2.Evaluation of low contrast resolution. The purpose is to establish an absolute evaluation method for low contrast imaging of CT scanning devices. The present invention provides an objective method for evaluating the comparability of low-contrast resolution when CT scanning devices are applied with reduced-dose technology. --- Part 3.Evaluation of dual energy imaging and energy spectrum application performance. The purpose is to establish the CT scanning device for dual energy imaging, or The present invention relates to an evaluation method for related image performance when energy spectrum is applied based on images or data obtained by corresponding acquisition modes. --- Part 4.Evaluation of imaging performance under automatic exposure control. The purpose is to establish the performance of the CT system under automatic exposure control. Standardized evaluation method for imaging performance. X-ray computed tomography image Quality assessment methods Part 4.Automatic exposure Evaluation of imaging performance under control

1 Scope

This document describes the automatic exposure control technology used in X-ray computed tomography equipment (hereinafter referred to as CT scanner). The corresponding imaging performance evaluation method is proposed. This document applies to whole-body and special-purpose CT scanning devices, including CT scanning devices that provide image data for radiation therapy planning.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB 9706.103-2020 Medical electrical equipment Part 1-3.General requirements for basic safety and essential performance Collateral standard. Radiation protection for diagnostic X-ray equipment GB 9706.244 Medical electrical equipment Part 2-44.Basic safety and essential performance safety of X-ray computed tomography equipment Fully dedicated requirements GB/T 10149 Terminology and symbols for medical X-ray equipment GB/T 19042.5 Evaluation and routine testing of medical imaging departments Part 3-5.X-ray computed tomography equipment imaging Performance acceptance test and stability test YY/T 1821 Calculation method for body-size-specific dose estimation of X-ray computed tomography equipment

3 Terms and definitions

GB/T 10149, GB 9706.103-2020, GB 9706.244, GB/T 19042.5 and YY/T 1821 and the following terms The following terms and definitions apply to this document. 3.1 In X-ray equipment, the process of automatically controlling one or more loading factors to obtain the required radiation dose at a preselected location. model. [Source. GB 9706.103-2020, 3.10] 3.2 In X-ray equipment, an operating mode in which the X-ray tube current is automatically modulated to obtain the required radiation dose at a preselected position. 3.3 An optimized constant X-ray flux can be determined for exposure control throughout the scanning sequence.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1766.4-2024_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1766.4-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1766.4-2024_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1766.4-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.