YY/T 1627-2018 English PDFUS$259.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 1627-2018: General requirements of acute adhesive wound dressing and woundplast Status: Valid
Basic dataStandard ID: YY/T 1627-2018 (YY/T1627-2018)Description (Translated English): General requirements of acute adhesive wound dressing and woundplast Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C48 Classification of International Standard: 11.120.20 Word Count Estimation: 13,156 Date of Issue: 2018-11-07 Date of Implementation: 2019-11-01 Quoted Standard: GB/T 14233.1-2008; GB/T 16886.1; GB/T 19633.1; YY/T 0148-2006; YY/T 0466.1; YY/T 0471.1-2004; YY/T 0471.3-2004; YY/T 0471.4-2004; YY/T 0615.1 Regulation (derived from): Announcement No. 87 of 2018 by the State Drug Administration Issuing agency(ies): State Drug Administration Summary: This standard specifies the general requirements for the application and creation of acute wounds for surgical incisions, punctures or mechanical wounds. This standard is applicable to acute wound dressing and plastering, which consists of adhesive layer, absorbent pad and release layer. This standard does not apply to hydrocolloid application and creation of acute wounds. This standard does not apply to the application and creation of specific substances (silver, chitosan, etc.) containing antibacterial and anti-inflammatory effects. YY/T 1627-2018: General requirements of acute adhesive wound dressing and woundplast---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.General requirements of acute adhesive wound dressing and woundplast ICS 11.120.20 C48 People's Republic of China Pharmaceutical Industry Standard General requirements for application and creation of acute wounds Published on.2018-11-07 2019-11-01 implementation State Drug Administration issued ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. Publication of this document The organization does not assume responsibility for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of Shandong Medical Device Product Quality Inspection Center. This standard was drafted. Shandong Medical Device Product Quality Inspection Center, Shanghai Johnson & Johnson Co., Ltd., Minnesota Mining Manufacturing Medical Equipment (Shanghai) Co., Ltd., Zhende Medical Products Co., Ltd., Qingdao Hainuo Biological Engineering Co., Ltd. The main drafters of this standard. Zhang Limei, Fang Jun, Zhang Bo, Zhao Changshuai, Hua Yuran, Lu Jianguo, Gao Rongsheng.IntroductionAdhesive dressings for acute wounds are divided into two categories depending on the application. One type is cleaning used in medical institutions, Dressings for acute wounds after disinfection or suture; one type is outside the medical institution (such as in the public, workshops, etc.) A dressing for temporary dressing of unsterilized or unstitched acute wounds caused by accidental injury. The application of the two dressings is not The corresponding requirements are different. The main role of the application is to keep the sterilized or closed wound sterile and provide a suitable healing ring. The main role of the creation is to provide temporary closure of hemostasis and isolation from uninsulated or unsewed wounds. This standard puts The former is named as a dressing, and the latter is named as a plaster to show the difference. These two terms apply only within the scope of this standard. This standard only specifies the general requirements for these two types of dressings, and does not specify their own special requirements. General requirements for application and creation of acute wounds1 ScopeThis standard specifies the general requirements for the application and creation of acute wounds for surgical incisions, punctures or mechanical wounds. This standard is applicable to acute wound dressing and plastering, which consists of adhesive layer, absorbent pad and release layer. This standard does not apply to hydrocolloid application and creation of acute wounds. This standard does not apply to the application and creation of specific substances (silver, chitosan, etc.) containing antibacterial and anti-inflammatory effects.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 14233.1-2008 Methods of test for infusions, blood trans GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management (GB/T 16886.1- 2011, ISO 10993-1..2009, IDT) GB/T 19633.1 End-sterilized medical device packaging - Part 1. Requirements for materials, sterile barrier systems and packaging systems YY/T 0148-2006 General requirements for medical tapes YY/T 0466.1 Medical devices for the labeling, marking and information of medical devices - Part 1. General requirements YY/T 0471.1-2004 Test methods for contact wounds - Part 1 . Fluid absorption YY/T 0471.3-2004 Test methods for contact wound dressings - Part 3 YY/T 0471.4-2004 Test methods for contact wounds - Part 4. Comfort YY/T 0615.1 Requirements for "sterile" medical devices - Part 1. Requirements for terminally sterilized medical devices3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Acute wound acupewound Wounds caused by external forces that are expected to heal within two weeks, including post-operative suture wounds, mechanical trauma, catheterization Waiting at the mouth, as well as bruises, stab wounds and cuts. 3.2 Applying wounddressing It consists of a differently shaped adhesive layer that can be adapted to various different pasting parts, an absorbent pad that is integrated with it, and a peelable release layer. The absorbent pad is mainly a variety of sheet-like absorbent materials, and some of the absorbent pads have a layer of perforated plastic film or the like to prevent adhesion to the wound surface. Provides a mechanical barrier to the wound and absorbs the wound exudate. It is commonly used in a variety of cleansed, disinfected or sutured acute wounds. 3.3 Wound woundplast It consists of a differently shaped adhesive layer that can be adapted to various adhesive parts, an absorbent pad that is integrated with it, and a peelable release layer. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1627-2018_English be delivered?Answer: Upon your order, we will start to translate YY/T 1627-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 1627-2018_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1627-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |