YY/T 1254-2015 English PDFUS$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 1254-2015: High density lipoprotein (LDL) cholesterol assay kit Status: Valid
Basic dataStandard ID: YY/T 1254-2015 (YY/T1254-2015)Description (Translated English): High density lipoprotein (LDL) cholesterol assay kit Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C44 Classification of International Standard: 11.100 Word Count Estimation: 9,984 Date of Issue: 2015-03-02 Date of Implementation: 2016-01-01 Quoted Standard: YY/T 0466.1 Regulation (derived from): The State Food and Drug Administration Announcement 2015 No. 8 Issuing agency(ies): State Food and Drug Administration Summary: This Standard provides a high-density lipoprotein cholesterol assay reagent (kit) requirements, test methods, marking, labeling and instructions for use, packaging, transportation and storage. This Standard applies to the use of the direct method in human serum or plasma high-density lipoprotein cholesterol quantitative detection reagent (kit), based on the principle of spectrophotometry, including manual reagents and on the semi-automatic biochemical analyzer used. YY/T 1254-2015: High density lipoprotein (LDL) cholesterol assay kit---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.High density lipoprotein (LDL) cholesterol assay kit ICS 11.100 C44 People's Republic of China pharmaceutical industry standards High-density lipoprotein cholesterol assay reagent (kit) Highdensitylipoprotein (HDL) cholesterolassaykit Issued on. 2015-03-02 2016-01-01 implementation China Food and Drug Administration released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national medical clinical laboratory testing and in vitro diagnostic systems for Standardization Technical Committee (SAC/TC136) centralized. This standard was drafted. Beijing Medical Device Testing, Shanghai Fuxing Changzheng Medical Science Co., Ltd., Beijing nine strong biotech stocks Parts Co., InTec (Xiamen) Technology Co., Ltd. Jiang Xi Tekang. The main drafters of this standard. Bi Chunlei, Wu Jie, Chen Yang, Wang Jun, Du Jiao, Xiao Yan. High-density lipoprotein cholesterol assay reagent (kit)1 ScopeThe standard provides a high-density lipoprotein cholesterol assay reagent (kit) requirements, test methods, marking, labeling and instructions for use, package Loading, transportation and storage. This standard applies to the use of the direct method in human serum or plasma high-density lipoprotein cholesterol quantitative detection reagent (box), the base Spectrophotometry in principle, including manual reagents and on the semi-automatic biochemical analyzer used.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Symbols - Part 1 YY/T 0466.1 medical equipment used with medical device labels, labeling and information. General requirements3 Requirements3.1 Appearance 3.1.1 Kit components should be complete, complete, no liquid leakage. 3.1.2 Packaging label text symbols should be clear. 3.2 PACKING Not less than the indicated value. 3.3 reagent blank absorbance When adding reagent blank sample test, the absorbance of the reagent blank should be < 0.05. 3.4 Sensitivity Analysis Determination of 1.00mmol/L sample, the two end-point method absorbance difference (ΔA) should be > 0.04; two-point rate method absorbance difference (ΔA/min) should be > 0.01. 3.5 Linear Reagent (box) linear in [0.20,2.50] mmol/L range. a) The linear correlation coefficient (r) shall be not less than 0.995; b) within [0.20,2.50] mmol/L range, linearity deviation should not exceed ± 0.10mmol/L or no more than ± 10%. 3.6 Precision 3.6.1 Repeatability Repeat the test (0.80 ± 0.20) mmol/L and (1.50 ± 0.50) mmol sample/L, and the results of the coefficient of variation (CV) should not ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1254-2015_English be delivered?Answer: Upon your order, we will start to translate YY/T 1254-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 1254-2015_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1254-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |