YY/T 0987.5-2016 PDF EnglishUS$140.00 · In stock · Download in 9 seconds
YY/T 0987.5-2016: Implants for Surgery - Magnetic Resonance Compatibility - Part 5: Magnetically Induced Torque Test Method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsYY/T 0987.5-2016: Implants for Surgery - Magnetic Resonance Compatibility - Part 5: Magnetically Induced Torque Test Method---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0987.5-2016 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.40 C 35 Implants for Surgery - Magnetic Resonance Compatibility - Part 5. Magnetically Induced Torque Test Method 外科植入物 磁共振兼容性 Issued on: MARCH 23, 2016 Implemented on: JANUARY 1, 2017 Issued by. China Food and Drug Administration Table of ContentsForeword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 6 4 Overview of Test Method ... 8 5 Significance and Application ... 9 6 Instruments and Equipment ... 9 7 Test Sample ... 11 8 Procedures ... 11 9 Calculation ... 12 10 Report ... 12 Appendix A (Informative) Fundamental Principle ... 14 Bibliography ... 19 Implants for Surgery - Magnetic Resonance Compatibility - Part 5. Magnetically Induced Torque Test Method1 ScopeThis Part of YY/T 0987 includes test method for magnetically induced torque generated by medical devices as a result of static magnetic field in magnetic resonance environment; a comparison of magnetically induced torque and medical devices’ gravity moment. This Part does not involve other possible safety questions. These safety questions include, but are not limited to, magnetically induced displacement force generated by the spatial gradient of magnetic field, radio frequency heating and radio frequency induced heating, noise, interaction among medical devices, functions of medical devices and magnetic resonance system. In this Part, torque refers to static magnetic torque generated by MRI static magnetic field and implant’s magnetic moment. This Part does not include dynamic torque generated by the rotation of medical device as a result of the interaction between the static magnetic field and eddy current. Current in the wires might also generate torque. The sensitivity of torque measurement device shall be more than 1/10 of gravity moment; gravity moment equals the arithmetic product of the maximum linear size and the weight of medical device. This Part does not attempt to elaborate all the involved safety questions, even though those safety questions are related with the usage. Determining appropriate safety and health specifications and clarifying the applicability of management limit before application is the responsibility on the users of this Standard.2 Normative ReferencesThe following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard. YY/T 0987.1 Implants for Surgery - Magnetic Resonance Compatibility - Part 1. Safety Marking YY/T 0987.2 Implants for Surgery - Magnetic Resonance Compatibility - Part 2. images and/or spectrograms, other physical parameters can also be obtained. 3.7 Magnetic Resonance (MR) Environment Magnetic resonance environment refers to the space within 0.5 mT (5G) line in MR system, including the whole three-dimensional space around MR scanner. When 0.5 mT line is included in Faraday cage, the whole space shall be deemed as magnetic resonance (MR) environment. 3.8 Magnetic Resonance Equipment MR Equipment Magnetic resonance equipment refers to medical electrical equipment that is expected to be applied to in vivo magnetic resonance examination. Magnetic resonance equipment includes all hardware and software parts from main power to display monitor. Magnetic resonance equipment is programmable electrical medical system (PEMS). 3.9 Magnetic Resonance Examination MR Examination Magnetic resonance examination refers to the process of gathering patients’ data through magnetic resonance. 3.10 Magnetic Resonance Imaging; MRI Magnetic resonance imaging refers to the imaging technology, which utilizes static time-varying magnetic field to generate resonance of atomic nucleus to obtain tissue images. 3.11 Magnetic Resonance System MR System Magnetic resonance system refers to the combination of magnetic resonance equipment, accessories (including display, control and energy supply devices) and controlled entry zone (if provided). 3.12 Magnetically Induced Displacement Force Magnetically induced displacement force refers to the force on magnetic object in spatial gradient magnetic field. This force will lead to movement of magnetic object in the gradient field. 3.13 Magnetically Induced Torque Magnetically induced torque refers to the torque generated by magnetic object in in the middle of the magnetic object of magnetic resonance equipment, where magnetic field is even. The size of torque depends on the loading tray’s deflection angle relative to an equilibrium position. By rotating the supporting torsional spring and the frame of the loading tray, the deflection angle of implant can be measured. Thus, the torque can be calculated. Compare the maximum torque with the severest gravity moment of medical device; the severest gravity moment equals to the arithmetic product of medical device’s maximum linear size and weight.5 Significance and ApplicationThe test method in this Part is is one of the test methods of determining whether the existence of medical devices would lead to patients’ injury in MR examination or MR environment. Other safety questions that need to be described include, but are not limited to, magnetically induced displacement force (refer to YY/T 0987.2) and radio frequency induced heating (refer to YY/T 0987.4). In order to guarantee the safety of medical devices in magnetic resonance environment, terms and markings stipulated in YY/T 0987.1 shall be applied to the marking of medical devices. If the maximum torque is less than the arithmetic product of medical device’s maximum size and weight, then, magnetically induced torque is less than the severest gravity moment generated by gravity. Under this circumstance, it can be deemed that the risk of magnetically induced torque is not higher than risks of daily activities in the earth’s gravity field. This is merely conservative estimation; it is possible that a larger torque also would not bring any hazard to patients. This test is insufficient to prove medical devices’ safety in magnetic resonance environment. The sensitivity of torque measurement device shall be more than 1/10 of gravity moment; gravity moment equals the arithmetic product of the maximum linear size and the weight of medical device. In this Part, torque refers to static magnetic torque generated by MRI static magnetic field and implant’s magnetic moment. This Part does not include dynamic torque generated by the rotation of medical device as a result of the interaction between the static magnetic field and eddy current. Current in the wires might also generate torque.6 Instruments and EquipmentTest device is shown in Figure 1. The device is constituted of a solid structure, including a loading tray supported by torsional spring. The device is completely made of non- ferromagnetic materials. Test sample shall be pasted or bundled on the loading tray. A protractor (division value. 1°) shall be fixated on a supporting structure. There is a marking on the loading tray, through which, the included angle of the loading tray and above test process. In terms of conductors, try to place them in accordance with the physical configuration in vivo. If it is feasible, conductors shall load the electric current during the application in vivo.9 CalculationTorque . signifies the loading tray’s deflection angle relative to the equilibrium position. The equilibrium position is the loading tray’s deflection angle relative to the fixed pedestal in magnetic field-free area. signifies the torsional spring’s elastic coefficient.10 ReportIn terms of each test sample, report shall include the following content. a) Description of test product, including dimension figures or photos (with scale) of medical devices; b) Sketch maps or photos of three sample configurations in tests; c) Medical devices’ product identification (such as batch, batch number, model number, version number, serial number and date of production); d) Materials (stipulated materials or others); e) Quantity of test samples and dimensional specification of selected samples; f) The mass of sample; g) Dimension drawings or photos of medical devices (with scale); h) Type of magnetic object; magnetic field strength B0 of static magnetic field; i) Take the central point of magnetic object as the original point; use Cartesian coordinates (x, y, z) of the gravity center of the medical device, which is determined through right-hand screw rule; including a sketch map of magnetic resonance system and coordinate axis; j) Sketch map or photo of test device, including torsional spring’s elastic coefficient; k) Draw sketch maps of torque (unit. Nm) angle; the angle is the deflection angle of medical device’s principal axis relative to the direction of static magnetic field;Appendix A(Informative) Fundamental Principle A.1 Principle The test method in this Part is mainly used to determine torque generated by medical devices as a result of the action of magnetic field in magnetic resonance imaging examination or magnetic resonance environment. It needs to be pointed out that this Part merely provides the test method for magnetically induced torque, and by merely relying on this test result, it is impossible to determine medical devices’ safety in magnetic resonance environment. As described below, when medical devices’ magnetic moment is in an inconsistent direction with the static magnetic field, torque would be generated. Meanwhile, static magnetic field would generate attraction towards medical devices; such attraction drives ferromagnetic objects to move towards the center of magnetic object. In terms of medical devices that are safe in MR environment, magnetically induced displacement force and torque shall be less than the displacement force and torque that the medical devices receive when they are not in large magnetic field space. For example, the displacement force shall be less than the weight of medical devices; the torque shall be less than the torque generated by daily activities (might include fast acceleration of vehicles or roller coasters in amusement park). Other possible safety questions include, but shall not be limited to, radio frequency heating, radio frequency induced heating, noise, interaction among medical devices, functions of medical devices and magnetic resonance system. Although the most commonly seen environment is 1.5T MR system environment for medical devices, 3T MR system has entered the market and has been increasingly commonly applied to clinic. It is worth noticing that safe medical devices in 1.5T scanning system are not necessarily safe in a system with higher or lower magnetic field strength (for example, 3T or 1T system). Furthermore, open-ended and cylindrical MR system might also have significant differences. For example, the static magnetic field spatial gradient of an open-ended system is obviously higher. After determining the safety of medical devices, apply the terms and markings provided in YY/T 0987.1 to the marking. MR safe, MR conditional or MR unsafe. Please see the terms and definitions in YY/T 0987.1 below. MR safe---objects that do not generate already known hazards in all MR environments. NOTE. MR safe objects include non-conductive and non-magnetic objects, for example, plastic petri dish. Whether objects are MR safe can be determined in accordance with scientific theories, not experimental data. MR conditional---objects that do not generate already known hazards under specific ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of YY/T 0987.5-2016 be delivered?Answer: The full copy PDF of English version of YY/T 0987.5-2016 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of YY/T 0987.5-2016_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0987.5-2016_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 0987.5-2016 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of YY/T 0987.5-2016?A step-by-step guide to download PDF of YY/T 0987.5-2016_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "YY/T 0987.5-2016". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |