YY/T 0941-2014 English PDFUS$209.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0941-2014: Medical endoscopes. Endotherapy device. Punch forceps Status: Valid
Basic dataStandard ID: YY/T 0941-2014 (YY/T0941-2014)Description (Translated English): Medical endoscopes. Endotherapy device. Punch forceps Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C40 Classification of International Standard: 11.040.99 Word Count Estimation: 9,925 Date of Issue: 6/17/2014 Date of Implementation: 7/1/2015 Quoted Standard: GB/T 1962.1; GB/T 4340.1-2009; GB 9706.4; GB 9706.19; GB/T 14233.1-2008; GB/T 14233.2-2005; GB/T 16886.1; YY/T 0149-2006; GB/T 1962.2; GB/T 16886.2; GB/T 16886.3; GB/T 16886.4; GB/T 16886.5; GB/T 16886.6; GB/T 16886.7; GB/T 16886.8; GB/T 16886.9; GB/T 168 Regulation (derived from): China Food and Drug Administration in 2014 Bulletin No. 30 Issuing agency(ies): State Food and Drug Administration Summary: This Standard applies to the use of endoscopic surgery bite cutting pliers. This Standard specifies the bite cutting pliers scope, terms and definitions, requirements, test methods. YY/T 0941-2014: Medical endoscopes. Endotherapy device. Punch forceps---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Medical endoscopes.Endotherapy device.Punch forceps ICS 11.040.99 C40 People's Republic of China pharmaceutical industry standards Medical endoscope endoscopic instruments bite cutting pliers Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some content of this document may involve patents, publication of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national medical and optical instruments Standardization Technical Committee (SAC/TC103/SC1) centralized. This standard was drafted. Zhejiang Medical Device Testing Institute, the State Food and Drug Administration Medical Device Quality Supervision, Inspection and Hangzhou center. The main drafters. Zhang Qin Yuan, JIA Xiao Hang, Yen to green. Medical endoscope endoscopic instruments bite cutting pliers1 ScopeThis standard specifies the cutting pliers bite the scope, terms and definitions, requirements, test methods. This standard applies to the use of endoscopic surgical cutting pliers bite.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1962 (all parts) syringes, needles and other medical equipment - 6% (Luer) conical fitting GB/T 4340.1-2009 metal materials - Vickers hardness test - Part 1. Test methods GB 9706.4 Medical electrical equipment - Part 2-2. requirements for the safety of high frequency surgical equipment GB 9706.19 Medical electrical equipment - Part 2. Safety of endoscopic equipment GB/T 14233.1-2008 Infusion, transfusion, injection equipment - Part 1. Chemical analysis GB/T 14233.2-2005 Infusion, transfusion, injection equipment test methods - Part 2. Biological test methods Biological evaluation of GB/T 16886 (all parts) Medical Devices YY/T 0149-2006 stainless steel medical equipment corrosion test methods3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Bite cutting pliers punchforceps One kind specified endoscope with endoscopic instruments used mainly by the handle, clamp lever clamp composition for bite and cut tissue. NOTE. The organization does not include bone tissue. 3.2 Inserting portion insertionportion Biting part of cutting pliers, which can be inserted into the body part natural orifice or a surgical incision, or insertion of the endoscope instrument channel, or attached to an endoscope Member of the instrument channel, instrument channel of the endoscope or instrument. 3.3 Maximum insertion portion width maximuminsertionportionwidth The maximum width of the outer portion of the insert. 3.4 Working length workinglength Cutting pliers bite the maximum length of the insertion portion. 3.5 Endoscopic instruments endotherapydevice In endoscopic surgery, to check, diagnostic or therapeutic purposes, and the endoscope through the same or different channels to enter the body's natural hole ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0941-2014_English be delivered?Answer: Upon your order, we will start to translate YY/T 0941-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0941-2014_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0941-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |