Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0938-2014 English PDF

US$299.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0938-2014: Guide for the check of B mode ultrasonic diagnostic equipment
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0938-2014299 Add to Cart 3 days Guide for the check of B mode ultrasonic diagnostic equipment Valid

Similar standards

YY 0789   YY/T 0937   YY/T 1090   YY 0599   YY/T 0939   

Basic data

Standard ID: YY/T 0938-2014 (YY/T0938-2014)
Description (Translated English): Guide for the check of B mode ultrasonic diagnostic equipment
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C41
Classification of International Standard: 11.040.50
Word Count Estimation: 13,177
Date of Issue: 6/17/2014
Date of Implementation: 7/1/2015
Quoted Standard: GB 10152-2009
Regulation (derived from): China Food and Drug Administration in 2014 Bulletin No. 30
Issuing agency(ies): State Food and Drug Administration
Summary: This Standard applies to assist medical practitioners, biomedical engineers, medical physicists, medical equipment maintenance performance, professional testers, inspection agency or the manufacturer, such as verification of B-mode ultrasound diagnostic e

YY/T 0938-2014: Guide for the check of B mode ultrasonic diagnostic equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guide for the check of B mode ultrasonic diagnostic equipment ICS 11.040.50 C41 People's Republic of China pharmaceutical industry standards B-mode ultrasound diagnostic equipment verification Guide Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard by the standardization of medical ultrasound equipment for medical appliances National Standardization Technical Committee Technical Committee (SAC/TC10/SC2) Centralized. This standard was drafted. State Food and Drug Administration of Hubei Medical Device Quality Supervision and Inspection Center, Institute of Acoustics, CAS The study. The main drafters of this standard. Wang Zhijian, cattle Fengqi, Jiang Shilin.

Introduction

This standard is intended for internal medical use of B-type ultrasonic diagnostic equipment performance verification, establish a standardized approach to technology Requirements and test methods provide guidance. To ensure the B-type ultrasonic diagnostic equipment in normal use, the need for periodic verification. This standard specifies the acceptance inspection, Weekly and annual inspection verification testing three kinds of forms. Receiving inspection and verification equipment and/or performance of the repaired equipment delivery; weekly test is simple The verification of equipment operation; the annual survey is a supplement to the weekly inspection, provides more detailed verification of the content. This standard provides weekly Examples of annual inspection reports and test. Weekly inspection shall be borne by the tester medical institutions, such as medical practitioners and so on. Receiving inspection, annual inspection by a skilled testers, Such as biomedical engineers, medical physicists, medical equipment maintenance personnel, professional testers, inspection agencies or manufacturers, etc. bear. B-mode ultrasound diagnostic equipment verification Guide

1 Scope

This standard specifies the medical institutions B-type ultrasonic diagnostic apparatus (hereinafter referred to as "B super") acceptance inspection, weekly inspection and annual inspection Requirements and test methods. This standard describes the method used to assist the B-user performance verification of such equipment, which is mainly applied to medicine Practitioners, biomedical engineers, medical physicists, medical equipment maintenance personnel, professional testers, inspection agency or the manufacturer and the like.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 10152-2009 B-type ultrasonic diagnostic equipment

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Phantom phantom And wherein the tissue mimicking material embedded in one or more groups target structure composed of B-test device. 3.2 Tester tester Trained, appropriately qualified, authorized to B super performance testing or inspection personnel, including medical practitioners, Biomedical engineers, medical physicists, medical equipment maintenance personnel, professional testers, inspection agency or the manufacturer and the like. 3.3 Baseline baselinevalues Baseline values specified by the tester B-quality indicators. Baseline data and numerical tests and annual tests weekly, and determines B-off is in normal working condition. NOTE. You can use the new purchase or repair the B-test results received as a baseline; you can also use the results of the annual survey as a baseline for the next year. 3.4 Verification check System actions to ensure the safety of medical institutions B-effective and taken, including receiving inspection, weekly inspection and annual inspection.

4 Content Verification

4.1 receiver test 4.1.1 After the B-delivered to the user for the first test, the performance when verification equipment delivery and/or equipment after the repair. 4.1.2 In addition to the content of the test carried out by the contract, but also including at least content of the annual inspection. 4.1.3 The test results received test as a baseline value B super performance.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0938-2014_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0938-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0938-2014_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0938-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.