Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0919-2014 English PDF

US$174.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0919-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0919-2014174 Add to Cart 3 days Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants Valid

Similar standards

YY/T 0962   YY/T 0987.1   YY/T 0987.2   YY/T 0924.2   YY/T 0917   

Basic data

Standard ID: YY/T 0919-2014 (YY/T0919-2014)
Description (Translated English): Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C35
Classification of International Standard: 11.040.40
Word Count Estimation: 9,964
Date of Issue: 6/17/2014
Date of Implementation: 7/1/2015
Quoted Standard: YY/T 0640-2008; YY/T 0810.1; YY/T 0924.1; ISO 14243.1; ISO 14243.2; ISO 14243.3; ISO 21534-2007
Adopted Standard: ISO 21536-2007, IDT
Regulation (derived from): China Food and Drug Administration in 2014 Bulletin No. 30
Issuing agency(ies): State Food and Drug Administration
Summary: This Standard applies to knee replacement implants. This Standard specifies the expected performance of knee replacement implants, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the man

YY/T 0919-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-active surgical implants.Joint replacement implants.Specific requirements for knee-joint replacement implants ICS 11.040.40 C35 People's Republic of China pharmaceutical industry standards Active surgical implants - Joint replacement implants Knee replacement implant-specific requirements (ISO 21536.2007, IDT) Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the translation method identical with ISO 21536.2007 "active surgical implants - Joint replacement implants implanted knee replacement Requirements for the material. " This standard and ISO 21536.2007 as compared to only normative references have been adjusted to technical differences, in order to adapt to China Technical conditions, the consistency of the correspondence between the standard international documents and normative references of the following documents. YY/T 0640-2008 active surgical implants General requirements (ISO 14630.2005, IDT) YY/T 0810.1-2010 surgical implant a total knee prosthesis - Part 1. Determination of fatigue properties of the tibial tray (ISO 14879-1.2000, IDT) Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national surgical implants and orthopedic instruments Standardization Technical Committee materials and orthopedic implants Technical Committee (SAC / TC110/SC1) centralized. This standard was drafted. China Medical Device Industry Association of Professional Committee of surgical implants, the State Food and Drug Administration, Tianjin Medical Therapy Devices Quality Supervision and Inspection Center, Beijing Air Materiel Biam tech Co., Ltd., a Johnson Medical Devices (China) Co., Ltd. The main drafters of this standard. Sun Jianwen, Yao Zhi repair, Zhang said, Dongshuang Peng, Liang Fanghui, Zhouxue Yu, Cheng Hongyuan.

Introduction

Standard relates to active surgical implants and related instruments are divided into three levels, involving the implant itself standard grades are as follows (a Standards for the highest). --- One. General requirements for passive surgical implants; --- Class 2. Particular requirements for various types of active surgical implants; --- Three levels. active surgical implants for a variety of special requirements. The standard for the three standards, including a dedicated knee replacement implant requirements. A standard YY/T 0640 contains apply to all active surgical implant requirements, but also prompt in the secondary and tertiary standards There are some additional requirements. Secondary standard applies to more limited class of active surgical implants, such as those designed for osteosynthesis, cardiovascular surgery, or joint home In other implants. To understand all the requirements, should the current minimum level of standard inspection began. Active surgical implants - Joint replacement implants Knee replacement implant-specific requirements

1 Scope

This standard specifies the knee replacement implant-specific requirements. General safety, this standard specifies the expected performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and manufacturers Information, as well as the requirements, test methods.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. YY/T 0640-2008 active surgical implants General requirements (ISO 14630.2005, IDT) YY/T 0810.1 surgical implant a total knee prosthesis - Part 1. Fatigue properties of knee tibial tray Determination (YY/T 0810.1-2010, ISO 14879-1.2000, IDT) YY/T 0924.1 Implants and total knee prosthetic components - Part 1. Classification, definitions and dimensions (YY/T 0924.1-2014, ISO 7207-1.2007, MOD) ISO 14243-1 Implants for surgery - Wear of total knee prostheses - Part 1. load control load and wear tester position Shift parameters and the corresponding environmental conditions for test (Implantsforsurgey-Wearoftotalknee-jointprostheses-Part 1. Loadinganddisplacementparametersforwear-testingmachineswithloadcontrolandcorresponding enviromentconditionsfortest) ISO 14243-2 Implants for surgery - Wear of total knee prostheses - Part 2. Methods of measurement (Implantsforsurgey- Wearoftotalknee-jointprostheses-Part 2. Methodsofmeasurement) ISO 14243-3 Implants for surgery - Wear of total knee prosthesis Part 3. displacement control load and wear tester position Shift parameters and the corresponding environmental conditions for test (Implantsforsurgey-Wearoftotalknee-jointprostheses-Part 3. Loadinganddisplacementparametersforwear-testingmachineswithdisplacementcontrolandcorre- spondingenvironmentalconditionsfortest) ISO 21534.2007 active surgical implants - Joint replacement implants - Particular requirements (Non-activesurgery-Jointre- placementimplants-Particularrequirements)

3 Terms and Definitions

ISO 21534 and YY/T 0924.1 and the definition of the following definitions apply to this document. 3.1 Femoral component femoralcomponent For fixing on the femur and total knee replacement articular surface replacement parts. NOTE. These implants may be manufactured in one piece or set of components assembled by the user.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0919-2014_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0919-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0919-2014_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0919-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.