Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0892-2013 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0892-2013: Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0892-2013169 Add to Cart 3 days Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies Valid

Similar standards

YY/T 0889   YY/T 0888   YY/T 0890   YY/T 0887   

Basic data

Standard ID: YY/T 0892-2013 (YY/T0892-2013)
Description (Translated English): Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 7,788
Quoted Standard: GB 9706.11-1997; GB 9706.12-1997; GB/T 10149-1988
Regulation (derived from): State Food and Drug Administration Notice No. 36 of 2013; industry standard for filing Notice 2013 No. 12 (No. 168 overall)
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies: medical diagnostic X -ray tube assemblies (hereinafter referred to as tube assembly) radiation leak testing Terminology and definitions, test methods side. This standard applies to: Non -pressure generating device capacitor discha

YY/T 0892-2013: Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for the measurement of leakage radiation of medical diagnostic X-ray tube assemblies ICS 11.040.50 C43 People's Republic of China pharmaceutical industry standards Medical Diagnostic X-ray tube assembly leakage radiation Test Methods Issued on. 2013-10-21 2014-10-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the China Food and Drug Administration. This standard by the National Standardization Technical Committee on Medical Electrical medical X-ray equipment and utensils Standardization Technical Committee (SAC / TC10/SC1) centralized. This standard was drafted. Liaoning Provincial Medical Device Testing, Siemens Aiks ray Vacuum Technology (Wuxi) Co., Ltd., Hangzhou Chiron Medical Devices Co., Ltd., Hangzhou Wandong Electronics Co. The main drafters of this standard. Wang Bo, Zhang can, Wangsong Dong, Hu Youcheng, Wang Jianjun, Zhang Yong. Medical Diagnostic X-ray tube assembly leakage radiation Test Methods

1 Scope

This standard specifies the diagnostic X-ray tube assemblies (hereinafter referred to as tube assembly) terms and definitions radiation leak test, the test method. This standard applies to the radiation leak testing apparatus tube assembly loaded non-state high voltage capacitor discharge occurs.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 9706.11-1997 Medical electrical equipment - Part II. diagnostic X-ray source assemblies and X-ray tube assemblies Claim GB 9706.12-1997 Medical electrical equipment Part 1. General requirements for safety Collateral standard diagnostic X-ray equipment. General requirements for radiation protection GB/T 10149-1988 X-ray equipment for medical terminology and symbols

3 Terms and Definitions

GB 9706.11-1997, GB 9706.12-1997, GB/T 10149-1988 definition of terms and definitions apply to this document. Test Method 4 4.1 Test environment conditions Unless otherwise stated, the environmental conditions should be met. a) Ambient temperature. 10 ℃ ~ 40 ℃; b) Relative humidity. 30% to 75%; c) Atmospheric Pressure. 700hPa ~ 1060hPa. 4.2 Spherical Detection Method 4.2.1 The use of instruments and devices Ionization chamber (100cm2, the length of not more than 20cm), stereotype (thickness not less than 4mm) or has an equivalent effect of radiation protection material. 4.2.2 Test layout and step Test layout and the steps in the following way. a) Figure 1 Several ionization chamber placed on a semi-circle with a radius of 1m, the ionization chamber filled with the continuous over the entire semi-circle, and the ionization chamber Receiving surface being the center of the semi-circle;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0892-2013_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0892-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0892-2013_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0892-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.