Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0865.1-2024 English PDF

US$1649.00 ยท In stock
Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0865.1-2024: Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
Status: Valid

YY/T 0865.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0865.1-20241649 Add to Cart 10 days Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields Valid
YY/T 0865-20112119 Add to Cart 5 days [YY/T 0865.1-2011] The first part of the ultrasound hydrophone: 40MHz medical ultrasound field measurement and profiling

Similar standards

YY 0789   YY/T 0767   YY/T 0937   YY/T 0865.2   YY/T 0865.3   YY 0846   

Basic data

Standard ID: YY/T 0865.1-2024 (YY/T0865.1-2024)
Description (Translated English): Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C41
Classification of International Standard: 17.040.50
Word Count Estimation: 82,865
Date of Issue: 2024-07-08
Date of Implementation: 2026-07-20
Older Standard (superseded by this standard): YY/T 0865.1-2011
Issuing agency(ies): State Drug Administration

YY/T 0865.1-2024: Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 17.040.50 CCSC41 Pharmaceutical Industry Standards of the People's Republic of China Replaces YY/T 0865.1-2011 Ultrasonic hydrophones Part 1.Measurement of medical ultrasound fields Measurement and characterization (IEC 62127-1.2022,MOD) Released on 2024-07-08 2026-07-20 implementation The State Drug Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 Symbol 20 5 Measurement requirements 22 6 Measurement Steps 29 7 Beam Characterization 30 8 Requirements for special ultrasound fields 35 9 Declaration of Conformity38 Appendix A (Informative) Principle Description 40 Appendix B (Informative) Hydrophone and Positioning System 42 Appendix C (Informative) Sound Pressure and Sound Intensity 47 Appendix D (Informative) Conversion of voltage to sound pressure 48 Appendix E (informative) Correction for spatial average effects 54 Appendix F (Informative) Acoustic output parameters of multi-mode medical ultrasound fields in the absence of scanning frame synchronization 57 Appendix G (Informative) Transmission media and degassing 62 Appendix H (Informative) Special Ultrasonic Fields 63 Appendix I (Informative) Uncertainty assessment of acoustic quantities measured by hydrophones 66 Appendix J (Informative) Transducer and Hydrophone Positioning System 68 Appendix K (Informative) Beam Width Midpoint Method 69 References 70

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is Part 1 of YY/T 0865 Ultrasonic Hydrophones. YY/T 0865 has been published in the following parts. --- Part 1.Measurement and characterization of medical ultrasound fields; --- Part 2.Calibration of hydrophones in ultrasonic fields below 40 MHz; --- Part 3.Characteristics of hydrophones for ultrasonic fields below 40 MHz. This document replaces YY/T 0865.1-2011 "Ultrasonic hydrophones Part 1.Measurement and characteristics of medical ultrasound fields below 40 MHz" Compared with YY/T 0865.1-2011, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope of application (see Chapter 1, Chapter 1 of the.2011 edition); --- Changed the normative references (see Chapter 2, Chapter 2 of the.2011 edition); --- Changed the terms and definitions (see Chapter 3, Chapter 3 of the.2011 edition); --- Changed the symbols (see Chapter 4, Chapter 4 of the.2011 edition); --- Changed the bandwidth (see 5.1.7, 5.1.7 of the.2011 edition); --- Changed the basic sound pressure parameters (see Chapter 7, Chapter 7 of the.2011 edition). This document is modified to adopt IEC 62127-1.2022 "Ultrasonic hydrophones Part 1.Measurement and characterization of medical ultrasound fields". The technical differences between this document and IEC 62127-1.2022 and their reasons are as follows. --- IEC 61689 (see Chapter 8) was replaced by YY/T 0750 to adapt to my country's technical conditions; --- IEC 62127-2 (see Chapter 7 and Chapter 8) was replaced by YY/T 0865.2 to adapt to my country's technical conditions; --- IEC 62127-3 (see Chapter 5 and Chapter 8) was replaced by YY/T 0865.3 to adapt to my country's technical conditions; --- ISO 16269-6 (see Chapter 9) was replaced by GB/T 3359 to adapt to my country's technical conditions; --- Replaced ISO /IEC Guide 98-3.2008 (see Chapter 5, Chapter 6, Chapter 9) with JJF 1059.1-2012 to adapt to our The technical conditions of the country. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by the State Food and Drug Administration. This document is under the jurisdiction of the Medical Ultrasonic Equipment Subcommittee of the National Technical Committee for Standardization of Medical Electrical Appliances (SAC/TC10/SC2). This document was drafted by. Hubei Medical Device Quality Supervision and Inspection Institute. The main drafters of this document. Jiang Shilin, Wang Zhijian and Wu Chengzhi. The previous versions of this document and the documents it replaces are as follows. ---First published in.2011 as YY/T 0865.1-2011; ---This is the first revision.

Introduction

YY/T 0865 Ultrasonic hydrophone is a standard for ultrasonic hydrophones, which aims to specify the parameters, calibration and And characteristics, it is planned to consist of three parts. --- Part 1.Measurement and characterization of medical ultrasound fields. The purpose is to define the various acoustic parameters that can be measured using the hydrophone method. These parameters are used to specify and characterize the ultrasonic field propagating in liquids, especially water; they can be used to determine These parameters are measured in steps. --- Part 2.Calibration of hydrophones in ultrasonic fields below 40 MHz. The purpose is to specify the absolute calibration method and relative calibration method of hydrophones. (Comparative) Calibration method. --- Part 3.Characteristics of hydrophones for ultrasonic fields below 40 MHz. The purpose is to specify the characteristic requirements of hydrophones. Relevant measurement standards for specific devices, for example, YY/T 0750, GB/T 16846, YY/T 0644 or YY/T 0642, as applicable Acoustic parameters can be found in this document. In YY/T 0642, some additional measurement methods for attenuation parameters and indicators are described to meet Special requirements for the characterization of acoustic output of ultrasonic diagnostic equipment in GB 9706.237. The idea followed in this document is to describe in detail the characteristics of the sound field using sound pressure parameters, with sound pressure as the primary measurement quantity of the hydrophone. This document specifies several sound intensity parameters, but they are derived quantities and are valid only under certain assumptions related to the measured ultrasonic field. significance. Ultrasonic hydrophones Part 1.Measurement of medical ultrasound fields Measurement and characterization

1 Scope

This document describes a method for measuring the acoustic field produced by medical ultrasound equipment in liquids using calibrated hydrophones, including Bandwidth standards and calibration frequency range requirements for the spectral components of the sound field to be characterized. This document. --- A set of measurable acoustic parameters based on acoustic foundations is given; --- A set of auxiliary acoustic parameters that can be derived under specific assumptions of these measurements are given, called derived acoustic parameters; --- Gives the measurement steps that can be used to determine the sound pressure parameters; --- Gives the conditions for measuring acoustic parameters using calibrated hydrophones; ---Procedures for correcting for limitations caused by using hydrophones with limited bandwidth and limited sensitive element size are given, and the to estimate the corresponding uncertainty. This document applies to the measurement and characterization of medical ultrasound fields using ultrasound hydrophones. NOTE 1.The International System of Units is used in this document. For certain parameters, such as beam area and sound intensity, decimal multiples or sub-multiples are used for simplicity. For example, the sound beam area is expressed in cm2, and the sound intensity is expressed in W/cm2 or mW/cm2. NOTE 2 By definition, hydrophones may be of either piezoelectric or fibre optic type.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 3359 Statistical processing and interpretation of data - Determination of statistical tolerance intervals (GB/T 3359-2009, ISO 16269-6. 2005, IDT) YY/T 0750 Requirements and measurement methods for sound fields in the frequency range of 0.5MHz to 5MHz for ultrasonic therapy equipment (YY/T 0750- 2018,IEC 61689.2013,MOD) YY/T 0865.2 Ultrasonic hydrophones Part 2.Calibration of hydrophones for ultrasonic fields below 40 MHz (YY/T 0865.2- 2018,IEC 62127-2.2013,IDT) YY/T 0865.3 Ultrasonic hydrophones Part 3.Characteristics of hydrophones for ultrasonic fields below 40 MHz (YY/T 0865.3- 2013,IEC 62127-3.2007,IDT) JJF1059.1-2012 Evaluation and expression of measurement uncertainty (ISO /IEC Guide98-3, MOD) IEC 60565-1 Underwater acoustics - Hydrophone calibration - Part 1.Free-field calibration procedure for hydrophones hydrophones) IEC 63009 Ultrasonic therapy equipment - Sound field requirements and measurement methods in the frequency range of 20kHz to 500kHz 20kHzto500kHz)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0865.1-2024_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0865.1-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0865.1-2024_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0865.1-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY/T 0865.1-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0865.1-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.