YY/T 0863-2011: Medical endoscopes. Endoscope functional supply units. Roller irrigation and suction equipment
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0863-2011189 Add to Cart 3 days Medical endoscopes. Endoscope functional supply units. Roller irrigation and suction equipment Valid

Similar standards

YY 0843   YY/T 0842   YY 0847   YY 0861   YY/T 0862   YY/T 0871   

Basic data

Standard ID: YY/T 0863-2011 (YY/T0863-2011)
Description (Translated English): Medical endoscopes. Endoscope functional supply units. Roller irrigation and suction equipment
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C40
Classification of International Standard: 11.040.99
Word Count Estimation: 8,873
Date of Issue: 2011-12-31
Date of Implementation: 2013-06-01
Quoted Standard: GB 9706.1-2007; GB 9706.19-2000; GB/T 14233.2-2005; GB/T 14710; GB/T 16886.1; GB/T 16886.5-2003; GB/T 16886.7-2001; GB/T 16886.10-2005
Regulation (derived from): State Food and Drug Administration Notice No. 106 of 2011
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies requirements for medical endoscope with Roller wash aspirator (hereinafter referred to rinse suction) requirements. This standard applies to those used in endoscopic surgery Roller wash aspirator. The products are used in minimally invasive endoscopic surgery flushing and attractive.

YY/T 0863-2011: Medical endoscopes. Endoscope functional supply units. Roller irrigation and suction equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Medical endoscopes.Endoscope functional supply units.Roller irrigation and suction equipment ICS 11.040.99 C40 People's Republic of China pharmaceutical industry standards Medical endoscope endoscopic functional supply means Roller washing aspirator Issued on. 2011-12-31 2013-06-01 implementation State Food and Drug Administration issued

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the State Food and Drug Administration. This standard by the national medical and optical instruments Standardization Technical Committee (SAC/TC103/SC1) centralized. This standard was drafted. State Food and Drug Administration Hangzhou Medical Device Quality Supervision and Inspection Center, Zhejiang Medical Devices Unit The inspection. The main drafters of this standard. Yan Qing, the JIA Xiao Hang, Qi Weiming, He Tao, Chen Sheng come. Medical endoscope endoscopic functional supply means Roller washing aspirator

1 Scope

This standard provides for the medical endoscope Roller wash aspirator (hereinafter referred to as flushing sucker) requirements. This standard applies to endoscopic surgery Roller wash used in the attractor. The products are used in minimally invasive endoscopic surgery and rinse attract.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety GB 9706.19-2000 electrical equipment - Part 2. Safety of endoscopic equipment GB/T 14233.2-2005 Infusion, transfusion, injection equipment test methods - Part 2. Biological test methods GB/T 14710 medical electrical environmental requirements and test methods GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation of the risk management process and Test GB/T 16886.5-2003 Biological evaluation of medical devices - Part 5. In vitro cytotoxicity tests GB/T 16886.7-2001 Biological evaluation of medical devices - Part 7. Ethylene oxide sterilization residuals GB/T 16886.10-2005 Biological evaluation of medical devices - Part 10. irritation and delayed-type hypersensitivity test

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Functional endoscopic supply means endoscopefunctionalsupplyunits In the minimally invasive endoscopic diagnostic and (or) treatment/surgery, providing apparatus or equipment support functions.

4 Requirements

4.1 Structural requirements Rinse aspirator should be configured to have both flushing and compelling features. 4.2 Pressure limit 4.2.1 preset pressure adjustment range limit If the flushing attract the preset pressure limit is adjustable, the manufacturer shall give the preset limit pressure adjustment range, and should be flush with the sucker preset The actual pressure limit adjustment range consistent.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0863-2011_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0863-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0863-2011_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0863-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.