YY/T 0809.4-2018 English PDFUS$284.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0809.4-2018: Implants for surgery. Partial and total hip joint prostheses. Part 4: Determination of endurance properties and performance of stemmed femoral components Status: Valid YY/T 0809.4: Historical versions
Basic dataStandard ID: YY/T 0809.4-2018 (YY/T0809.4-2018)Description (Translated English): Implants for surgery. Partial and total hip joint prostheses. Part 4: Determination of endurance properties and performance of stemmed femoral components Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C35 Classification of International Standard: 11.040.40 Word Count Estimation: 15,179 Date of Issue: 2018-09-29 Date of Implementation: 2019-10-01 Older Standard (superseded by this standard): YY/T 0809.4-2010 Quoted Standard: ISO 3696; ISO 4965; ISO 7206-1 Adopted Standard: ISO 7206-4-2010, IDT Regulation (derived from): State Drug Administration Announcement No. 72 of 2018 Issuing agency(ies): State Drug Administration Summary: This standard specifies the test method for determining the fatigue performance of a shank femoral component in partial and total hip arthroplasty under specific test conditions. This section also specifies test conditions to consider important parameters affecting the test components and describes the method of installation of the test specimens. This section also specifies test parameters and femoral component fatigue limit requirements, including fatigue limit values ??and the corresponding number of load cycles. This section applies to prostheses with a symmetrical plane or prefabricated forward or double-sided shank. This part does not include the inspection method of the sample after the completion of the fatigue test. The content of this part is determined by the laboratory and the sample provider. For the fatigue test of the combined femoral component, a liquid test environment for the femoral component is specified. YY/T 0809.4-2018: Implants for surgery. Partial and total hip joint prostheses. Part 4: Determination of endurance properties and performance of stemmed femoral components---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Implants for surgery.Partial and total hip joint prostheses.Part 4. Determination of endurance properties and performance of stemmed femoral components ICS 11.040.40 C35 People's Republic of China Pharmaceutical Industry Standard Replacing YY/T 0809.4-2010 Surgical implant part and total hip prosthesis Part 4. Fatigue properties of femoral components with shank Test and performance requirements Part 4.Determinationofendurancepropertiesand (ISO 7206-4.2010, IDT) 2018-09-28 released.2019-10-01 implementation State Drug Administration issued ForewordYY/T 0809 "Surgical Implant Part and Total Hip Prosthesis" is divided into the following sections. --- Part 1. Classification and dimensioning; --- Part 2. Metal, ceramic and plastic joint surfaces; --- Part 3. (reserved); --- Part 4. Fatigue performance test and performance requirements for shank femoral components; --- Part 5. (reserved); --- Part 6. neck fatigue performance test and performance requirements for shank femoral components; --- Part 7. (reserved); --- Part 8. Fatigue performance of shank femoral components with torque; --- Part 9. (reserved); --- Part 10. Determination of the antistatic force of the combined femoral head. This part is the fourth part of YY/T 0809. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section replaces YY/T 0809.4-2010. Compared with YY/T 0809.4-2010, major technical changes except editorial changes as follows. ---The standard name was modified from "Determination of fatigue performance of shank femoral components" to "Fatigue performance test and performance of shank femoral components" Seeking", the standard has increased the fatigue performance requirements; --- Adjusted the test parameters. This section uses the translation method equivalent to ISO 7206-4.2010 "Surgical Implant Part and Total Hip Prosthesis Part 4. Belt Fatigue performance test and performance requirements for shank femoral components. The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. ---GB/T 6682-2008 Analytical laboratory water specifications and test methods (ISO 3696.1987, MOD); ---GB/T 25917-2010 axial force fatigue testing machine dynamic force calibration (ISO 4965. 1979, MOD); ---YY/T 0809.1-2010 Surgical implant part and total hip prosthesis Part 1. Classification and dimensioning (ISO 7206-1.2008, IDT). Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part is proposed by the State Drug Administration. This part is organized by the National Technical Committee for Standardization of Surgical Implants and Orthopedic Devices, orthopedic implants subcommittee (SAC/TC110/ SC1). This section drafted by. Tianjin Medical Device Quality Supervision and Inspection Center, Shanghai University, Chuangsheng Medical Devices (China) Co., Ltd., strong Health (Suzhou) Medical Equipment Co., Ltd. The main drafters of this section. Dong Shuangpeng, Zhang Zhenghui, Wang Wei, Hua Zikai, Chen Changsheng, Wang Jian, Zhao Yuanyi, Chen Ruiqi. The previous versions of the standards replaced by this standard are. ---YY/T 0809.4-2010.IntroductionSome aspects of the previous version are not fully described, and some aspects of the test method do not reflect actual test practices, as follows Said. a) The test conditions of the anteversion femoral stem result in a significant reduction in the bending force in the sagittal plane. Compared to the "worst case" of the non-forwardly inclined femoral stem Condition, this test condition becomes the "best case" because it does not consider the rotation of such a femoral stem when implanted in the human body, so it cannot be reversed. Reflects high stress conditions in the human body. b) The test of the femoral stem with a CT value less than 120 mm was not considered. Note. The CT value is the distance from the center of the femoral head to the most distal point of the femoral stem. c) The level of embedding has changed compared to YY/T 0809.4-2010, but is specified in the corresponding YY/T 0809.8-2010 The performance requirements have not changed. To compensate for these deficiencies, test conditions were defined for three types of femoral stems with different length ranges; more precise description of the test procedure and The definition of the stem axis, especially the forward-tilt stem; and the specified test conditions and performance requirements in YY/T 0809.8-2010 Adapted. This standard makes laboratory operations more precise and simple, and clearly divides the femoral stem into three types. ---CT ≤ 120mm femoral stem; ---CT > 250mm femoral stem. This standard covers the performance requirements of these components, which improves the acceptability of test methods and the reproducibility of test results. Surgical implant part and total hip prosthesis Part 4. Fatigue properties of femoral components with shank Test and performance requirements1 ScopeThis section of YY/T 0809 specifies the fatigue of shank femoral components in partial and total hip arthroplasty under specific test conditions. Test method for performance. This section also specifies test conditions to consider important parameters affecting the test components and describes the installation of the test specimens. method. This section also specifies test parameters and femoral component fatigue limit requirements, including fatigue limit values and the corresponding number of load cycles. This section applies to prostheses with a symmetrical plane or prefabricated forward or double-sided shank. This part does not include the inspection method of the sample after the completion of the fatigue test. The content of this part is determined by the laboratory and the sample provider. For the fatigue test of the combined femoral component, a liquid test environment for the femoral component is specified.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. ISO 3696 Laboratory Analytical Water Specification and Test Method (Waterforanalyticallaboratoryuse-Specification) Andtestmethods) ISO 4965 axial load fatigue tester dynamic force calibration strain measurement technology (Axialloadfatiguetestingma- chines-Dynamicforcecalibration-Straingaugetechnique) ISO 7206-1 Surgical Implant Part and Total Hip Prosthesis Part 1. Classification and Dimensioning (Implantsforsur- gery-Partialandtotalhipjointprostheses-Part 1. Classification and designationofdimensions)3 Terms and definitionsThe following terms and definitions as defined by ISO 7206-1 apply to this document. 3.1 Neck combination handle modularneckstem A handle that is used by taper fitting with a proximal end of the femoral neck with a self-locking taper. 3.2 Fatigue limit endurancelimit FD After ND cycle tests, the sample does not have maximum force for damage and deformation. 3.3 Fatigue cycle number endurancecycles ND The number of specified cycles under the test force value. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0809.4-2018_English be delivered?Answer: Upon your order, we will start to translate YY/T 0809.4-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0809.4-2018_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0809.4-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YY/T 0809.4-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0809.4-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |