YY/T 0616.5-2019 English PDFUS$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0616.5-2019: Medical gloves for single use -- Part 5: Test method for permeation of chemicals under conditions of continuous contact Status: Valid
Basic dataStandard ID: YY/T 0616.5-2019 (YY/T0616.5-2019)Description (Translated English): Medical gloves for single use -- Part 5: Test method for permeation of chemicals under conditions of continuous contact Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C48 Classification of International Standard: 11.140.01 Word Count Estimation: 13,141 Date of Issue: 2019 Date of Implementation: 2020-10-01 Issuing agency(ies): State Drug Administration Summary: This standard specifies the test conditions, test procedures and result reports for the resistance of single-use medical glove materials to penetration by liquid chemicals under continuous contact conditions. This standard applies to the evaluation of chemical penetration resistance of disposable medical gloves. YY/T 0616.5-2019: Medical gloves for single use -- Part 5: Test method for permeation of chemicals under conditions of continuous contact---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Medical gloves for single use-Part 5. Test method for permeation of chemicals under conditions of continuous contact ICS 11.140.01 C48 People's Republic of China Pharmaceutical Industry Standard Single-use medical gloves. Part 5. Test method for continuous penetration resistance against chemicals Published on October 23,.2019 2020-10-01 implementation Published by the State Drug Administration ForewordYY/T 0616 `` Disposable Medical Gloves '' is intended to be divided into the following parts. --- Part 1. Biological evaluation requirements and tests; --- Part 2. Requirements and tests for determining shelf life; --- Part 3. Method for determining the actual time expiry date with the finished gloves in storage; --- Part 4. Puncture resistance test method; --- Part 5. Test method for continuous exposure to chemical penetration; This part is Part 5 of YY/T 0616. This section is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some elements of this document may involve patents. The issuer of this document is not responsible for identifying these patents. This section is proposed by the State Drug Administration. This section is under the jurisdiction of Shandong Medical Device Product Quality Inspection Center. This section was drafted by. Shandong Medical Device Product Quality Inspection Center, Shijiazhuang Hongrui Group Co., Ltd., Lanfan Medical Co., Ltd. Limited company. The main drafters of this section. Zhang Limei, Guo Lijuan, Sun Xingxia, Liu Guixi, Liu Wei, Wu Changyan, and Sun Yupeng.IntroductionMedical workers may be exposed to chemicals that are harmful to healthy people at work (such as various disinfectants, chemical sterilants, Chemicals, etc.), causing various levels of harm to the human body, such as acute trauma such as skin irritation and burns, and chronic diseases such as cancer Variant disease. To avoid such hazards, medical personnel need to wear products with appropriate protective properties (such as medical gloves) to achieve effective The purpose of protection. The penetration of chemicals into protective product materials usually includes two forms. penetration and permeation, both of which The mechanism is completely different. The permeation tests in this section are based on the permeation mechanism (see 4.1). Penetration is when a substance passes through the medicine at a non-molecular level Use the movement of the voids in the glove material (including joint gaps, incomplete seals, and/or holes, holes, etc. in the material itself). Needless to penetrate The state changes, that is, the solid chemical passes through the voids of the material in a solid state, the liquid passes in a liquid state, and the gas passes in a gas state. At present, European and American countries require such protective gloves to indicate the type of protection (such as chemotherapy) or protection level (Such as level 1). A set of chemical resistance test equipment for medical gloves and a standard test method established in this section can be used to evaluate medical The resistance of gloves to liquid chemicals can better guide medical staff to choose suitable products for effective protection. This section establishes a general test method for chemical resistance of medical glove materials.It will give a specific application, that is, determine the resistance of medical glove materials to chemotherapy. Test method for drug permeability. Single-use medical gloves. Part 5. Test method for continuous penetration resistance against chemicals1 ScopeThis part of YY/T 0616 specifies the test of resistance to the penetration of liquid chemicals by disposable medical gloves under continuous exposure Test conditions, test procedures and results report. This section applies to the evaluation of chemical penetration resistance of disposable medical gloves.2 Normative referencesThe following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 2941 Rubber physical test method General procedure for sample preparation and adjustment GB/T 6682 Analytical laboratory water specifications and test methods3 terms and definitionsThe following terms and definitions apply to this document. 3.1 Breakthrough detection time The time elapsed from the start of exposure to the test chemical to the first detection of the test chemical. Note. The breakthrough detection time depends on the sensitivity of the method. 3.2 Standardizedbreakthroughtime Time when the permeation rate reaches 0.1 μg/(cm2 · min). 3.3 Steady-state permeation When chemicals are in continuous contact and all influencing infiltration factors have reached equilibrium, a constant velocity infiltration is formed after the breakthrough. 3.4 Collection medium colectionmedium A liquid that can absorb, adsorb, dissolve, suspend, or capture test chemicals without affecting the detection of penetrating chemicals. 3.5 Cumulative permeation The total amount of chemicals that penetrated a specific area of glove material from the time the material began to contact the test chemicals to a specific time. 3.6 Degradation Harmful changes in one or more properties of the glove material. Note. Usually the most concerned is the change of physical properties (such as swelling, etc.). ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0616.5-2019_English be delivered?Answer: Upon your order, we will start to translate YY/T 0616.5-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0616.5-2019_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0616.5-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |