YY/T 0094-2013 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0094-2013: X-ray fluorescent screens for medical diagnosis Status: Valid YY/T 0094: Historical versions
Basic dataStandard ID: YY/T 0094-2013 (YY/T0094-2013)Description (Translated English): X-ray fluorescent screens for medical diagnosis Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C43 Classification of International Standard: 11.040.50 Word Count Estimation: 10,173 Older Standard (superseded by this standard): YY/T 0094-2004 Quoted Standard: GB/T 191-2008; GB/T 2828.1-2012; GB/T 2829-2002; GB/T 9969-2008; GB/T 10149-1988 Regulation (derived from): State Food and Drug Administration Notice No. 36 of 2013; industry standard for filing Notice 2013 No. 12 (No. 168 overall) Issuing agency(ies): State Food and Drug Administration Summary: This standard specifies the diagnostic X-ray fluoroscopy screen (hereinafter referred to as the screen) terminology, requirements, test methods, inspection rules, marking, labeling, instruction manual and packaging, transportation and storage. This standa YY/T 0094-2013: X-ray fluorescent screens for medical diagnosis---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.X-ray fluorescent screens for medical diagnosis ICS 11.040.50 C43 People's Republic of China pharmaceutical industry standards Replacing YY/T 0094-2004 Medical Diagnostic X-ray fluoroscopy screen Issued on. 2013-10-21 2014-10-01 implementation China Food and Drug Administration released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. Instead of the standard YY/T 0094-2004 "Medical Diagnostic X-ray screen," compared with the YY/T 0094-2004 major change Of the following. --- Modify the standard's reference number; --- Modify the emission spectrum of the phosphor screen 4.5 main peak energy distribution range; --- 5.3 to 5.7 Test methods made editorial adjustments. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the China Food and Drug Administration. This standard by the National Standardization Technical Committee medical electrical medical X-ray equipment and utensils Standardization Technical Committee (SAC/TC 10/SC1) centralized. This standard was drafted. Liaoning Provincial Medical Device Testing. Drafters of this standard. Qu Yan. This standard replaces the previous version of the release of case. --- WS2-207-1982; --- YY/T 0094-1992, YY/T 0094-2004. Medical Diagnostic X-ray fluoroscopy screen1 ScopeThis standard specifies the diagnostic X-ray fluoroscopy screen (hereinafter referred to as the screen) terminology, requirements, test methods, inspection rules, Signs, labels, instruction manual and packaging, transportation and storage. This standard applies to the screen. The product is used for converting X-rays into visible light.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191-2008 Packaging - Pictorial signs GB/T 2828.1-2012 count batch inspection sampling plan Sampling procedures for inspection by acceptance quality limit (AQL) retrieval GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test) GB/T 9969-2008 General Industrial Product Manual GB/T 10149-1988 X-ray equipment for medical terminology and symbols3 Terms and DefinitionsGB/T 10149-1988 define the following terms and definitions apply to this document. 3.1 Limiting resolution limitingresolution The template smallest distance between two adjacent pairs as the image information can be distinguished on the ability of the film to the imaging resolution. Fluorescence Screen resolution is the limit of resolution test card using the screen image on the X-ray film, every millimeter maximum linear human eye can distinguish logarithm. 3.2 Emission spectrum emissionspectrum Emission energy distribution by wavelength or frequency. 3.3 Afterglow time lagtime Predetermined X-ray excitation, down from the instant stoppage of the excitation brightness to 10% of the brightness of the elapsed time.4 Requirements4.1 Working conditions Screen should meet the following conditions. a) Ambient temperature. 5 ℃ ~ 40 ℃; b) relative humidity less than 80%. 4.2 Basic dimensions 4.2.1 Size screen should meet the requirements of Table 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0094-2013_English be delivered?Answer: Upon your order, we will start to translate YY/T 0094-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0094-2013_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0094-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YY/T 0094-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0094-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |