YY/T 1040.1-2015 English PDFUS$354.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 1040.1-2015: Anaesthetic and respiratory equipment. Conical connectors. Part 1: Cones and sockets Status: Valid YY/T 1040.1: Historical versions
Basic dataStandard ID: YY/T 1040.1-2015 (YY/T1040.1-2015)Description (Translated English): Anaesthetic and respiratory equipment. Conical connectors. Part 1: Cones and sockets Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C46 Classification of International Standard: 11.040.10 Word Count Estimation: 18,134 Date of Issue: 2015-03-02 Date of Implementation: 2016-01-01 Older Standard (superseded by this standard): YY 1040.1-2003 Quoted Standard: GB 9706.1-2007; ISO 4135; ISO 5367 Adopted Standard: ISO 5356-1-2004, IDT Regulation (derived from): The State Food and Drug Administration Announcement 2015 No. 8 Issuing agency(ies): State Food and Drug Administration Summary: This Standard provides for the connection of anesthesia and respiratory devices (such as the respiratory system, anesthetic gas purification system and evaporator) size and measurement requirements cone and the cone sleeve. This section gives the requirements for the following conical connectors: pediatric respiratory system standard 8.5 mm connector; respiratory system common to 15 mm and 22 mm standard connector; 22 mm lock joints (including performance requirements); an evaporator 23 mm standard connectors, the specification does not apply to the respiratory system; for respiratory and anesthetic gas purification system connected to 30 mm standard connector. This part of the connection of medical devices and its auxiliary devices have been formed is not specified. The applicability of the requirements of the conical connector are not included in this section, but these requirements have been or will be given appropriate medical equipment and accessories standard. YY/T 1040.1-2015: Anaesthetic and respiratory equipment. Conical connectors. Part 1: Cones and sockets---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Anaesthetic and respiratory equipment.Conical connectors.Part 1. Cones and sockets ICS 11.040.10 C46 People's Republic of China pharmaceutical industry standards Replacing YY 1040.1-2003 Anaesthetic and respiratory equipment conical fitting Part 1. cone and cone sleeve Part 1. Conesandsockets (ISO 5356-1.2004, IDT) Issued on. 2015-03-02 2016-01-01 implementation China Food and Drug Administration released Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 conical metal fittings 1 4.1 General Requirements 1 Additional requirements 4.2 22mm conical connector 2 4.3 8.5mm conical connector 3 Additional requirements 5 3 non-metallic conical fitting 5.1 General requirements 3 5.2 22mm conical connector 3 Additional requirements 5.3 8.5mm conical connector 3 Additional requirements 6 22mm lock joints 4 Appendix A (normative) is used to test non-metallic cone joints plug and ring gauge 5 Appendix B (normative) are locked reliability test 22mm lock joints and outer conical joint 6 Appendix C (Normative Appendix) 22mm lock joints leak test 7 Annex D (normative appendix) 22mm lock joints drop test Step 8 Appendix E (Informative Appendix) is used for testing of metallic conical connector plug and ring gauges 9 Annex F (informative) Test 22mm lock joints are locked reliability test equipment and methods recommended 10 References 13ForewordYY 1040 "Anaesthetic and respiratory equipment cone joint" consists of the following components. --- Part 1. Cone head and sleeve; --- Part 2. threaded bearing joints. This is Part 1 YY 1040 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This part is YY 1040.1-2003 amendment of this revised standard main difference with the original criteria are as follows. --- Of the Preamble to do part of the text of the amendment, as modified to humidifier humidifier; --- Increased 8.5mm connector specifications relevant content, figures and tables and some minor changes, as shown in Table 1, Table A.1, Table E.1, An increase of 4.3 and 5.3 Additional requirements for 8.5mm standard conical joints; --- Delete the contents of Note 2 of 4.1; --- 5.1 Notes plastics material name be amended by deleting the polyacrylamide, an increase of polyacetal. --- Update Appendix A in Figure A.1; Appendix B title was modified; D.3 in Appendix D was amended; deleted Appendix F in F.2.2.5; deleted Appendix G, reference to literature; --- References GB 9706.1-1995 modified to reference GB 9706.1-2007, references GB/T 4999-1985 and YY 0461-2003 modify references to international standards. This section identical with the international standard ISO 5356-1.2004 "Anaesthetic and respiratory equipment conical fittings - Part 1. Cone and cone Set ", and made the following editorial changes. --- ISO 5356-1. ISO 2004 international standard referenced, there is a corresponding equivalent into national standards and industry standards, this section In reference to these national standards and industry standards for use as a specification; no correspondence now been adopted as national standards and industry standards, the To ISO international standard cited as a standard use. Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB/T 4999-2003 term anesthesia breathing equipment (ISO 4135.2001, IDT); --- YY 0461-2003 anesthesia machine and ventilator with a breathing circuit (ISO 5367.2000, IDT). Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Food and Drug Administration. This part of the National Standardization Technical Committee on Narcotic breathing apparatus and (SAC/TC116) centralized. This section is drafted. Shanghai Medical Device detection, Henan Electric Pfizer Biomedical Technology Limited. The main drafters of this section. Fu Guoqing, Wang, Wang Wei, Zhou Bin Zu. This section was first released in June 2003.IntroductionClinically, it may need more than one accessory respiratory Anaesthetic and respiratory equipment used together to form a suitable respiratory system. various Other medical devices such as humidifiers or spirometer, etc. are often used to connect to the respiratory system, respiratory system can also be connected to anesthetic gases Purification System. Often with cone and cone sleeve to achieve the connection between these devices, if these connections lack of standardization, different manufacturing It will bring compatibility problems when connected to each other's equipment. This section provides anesthesia and respiratory equipment used conical fitting requirements and size. Cone connection should be firm, but does not interfere with the operator to disengage this in mind is very important. Satisfying the requirements of this part The need to prevent accidental disengagement during piecing. To reduce the risk of accidental release of the 22mm connector, you can use the lock joints. Appendix A includes a ring gauge and plug gauge diagrams and charts used to test non-metallic cone joints. Appendix B, Appendix C, Appendix D regulation A set of test methods lock joints, including the Appendix E ring gauge and plug gauge test diagrams and charts metal cone joint, is given in Appendix F Lock joints safety testing recommendations. Figure 1 for dimensions and tolerancing metal conical connectors, and corresponding provisions in GB/T 15754 in. Anaesthetic and respiratory equipment conical fitting Part 1. cone and cone sleeve1 ScopeYY/T 1040 provisions of this section (such as respiratory, anesthesia gas purification system and an evaporator) for connection of anesthesia and respiratory equipment Size and measurement requirements and cone drogue. This section gives the requirements for the following conical connectors. --- For pediatric respiratory system specifications 8.5mm connector; --- Respiratory system common to 15mm and 22mm standard connector; --- 22mm lock joints (including performance requirements); --- An evaporator 23mm joint specifications, the specification does not apply to the respiratory system; --- For respiratory and anesthetic gas purification system connected 30mm standard connector. This section and its auxiliary devices connected to the medical device has been formed is not specified. The applicability of the requirements of the conical connector are not included in this section, but these requirements have been or will be in the appropriate standards for medical equipment and accessories Given. Note. YY/T 1040.2 specifies requirements for load-bearing cone threaded joint.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) ISO 4135 anesthesia-respiratory term (Anaestheticandrespiratoryequipment-Vocabulary) ISO 5367 anesthesia machine and ventilator with respiratory tract (Breathingtubesintendedforusewithanaestheticappara- tusandventilators)3 Terms and DefinitionsAs defined in ISO 4135 and the following terms and definitions apply to this document. 3.1 22mm lock joints 22mmlatchingconnector For inner conical connector and compliance with this specification 22mm outer conical fitting locks into contact. Its characteristics are available to reduce the accidental release Possibilities.4 metal conical fitting4.1 General requirements Conical metal fittings, made from other materials including but mating surface material is a metal joints shall comply with Figs. 1 and 2 and in Table 1. Note. The plug and ring gauges the size of joint requirements in Appendix E. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 1040.1-2015_English be delivered?Answer: Upon your order, we will start to translate YY/T 1040.1-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 1040.1-2015_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1040.1-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YY/T 1040.1-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 1040.1-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |