YY 0780-2025 English PDFYY 0780: Historical versions
Basic dataStandard ID: YY 0780-2025 (YY0780-2025)Description (Translated English): (Traditional Chinese Medicine Equipment - Electroacupuncture therapy device) Sector / Industry: Medical Device & Pharmaceutical Industry Standard Classification of Chinese Standard: G42 Classification of International Standard: 11.040.60 Date of Issue: 2025-06-18 Date of Implementation: 2028-07-01 Older Standard (superseded by this standard): YY 0780-2018 Issuing agency(ies): National Medical Products Administration YY 0780-2018: Electroacupuncture therapy device---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Electroacupuncture therapy device ICS 11.040.60 C42 People's Republic of China Pharmaceutical Industry Standard Replacing YY 0780-2010 Electroacupuncture treatment instrument Published on.2018-06-26 2019-07-01 implementation State Drug Administration issued ContentForeword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Requirements 2 5 Test method 4ForewordThe full technical content of this standard is mandatory. This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces YY 0780-2010 "Electric Needle Therapy Apparatus". Compared with YY 0780-2010, the main technical changes except editorial changes The following is as follows. --- Revised the definition of electroacupuncture treatment instrument and electroacupuncture (see 3.1, 3.2, 3.1, 3.3 of.2010 edition); --- Added the definition of electrode needle, electrode pin connector, electrode line, output terminal, output channel (see 3.3~3.7); ---Modified the pulse energy requirements and test methods (see 4.2.3, 5.2.1,.2010 edition of 4.7.2.4 line 4, 5.7); --- Increased requirements for output channel independent control, channel interference, output channel identification, output short circuit and open circuit protection and test Test method (see 4.4~4.7, 5.4~5.7); --- Modified the requirements and test methods for the electrode needle (see 4.8, 5.8, 4.5, 5.5 of the.2010 edition); --- Increased requirements and test methods for electrode pin connectors and electrode wires (see 4.9, 5.9); --- Increased requirements for external marking of equipment or equipment components (see 4.10.2.1); --- Revised the requirements for the accuracy of random files and work data (see 4.10.2.2, 4.10.2.3, 4.7.2.1, 4.7.2.2 of the.2010 edition); ---Modified the requirements for electromagnetic compatibility (see 4.11, 4.7.3 of the.2010 edition); --- Modified the test method of DC component (see 5.2.2, 5.2 of.2010 edition); --- Removed the definition of application part, load impedance, pulse width, output waveform, and operating frequency (2010, 3.2, 3.4~3.7). Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of the National Medical Electrical Equipment Standardization Technical Committee Physical Therapy Equipment Subcommittee (SAC/TC10/SC4). This standard was drafted. Tianjin Medical Device Quality Supervision and Inspection Center, Shanghai Daosheng Medical Technology Co., Ltd., Chengdu Huaxin Hi-Tech Medical Devices LLC. The main drafters of this standard. Zhang Wei, Qi Lijing, Zhang Haiming, Qian Xuebo, Zhou Huilin, Chen Xinyun. The previous versions of the standards replaced by this standard are. ---YY 0780-2010. Electroacupuncture treatment instrument1 ScopeThis standard specifies the terms and definitions, requirements and test methods of electroacupuncture treatment instruments (hereinafter referred to as therapeutic instruments). This standard applies to instruments that are treated and assisted by electroacupuncture.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 2024 acupuncture needle GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety GB/T 14710 Medical electrical requirements and test methods GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management YY 0505 Medical Electrical Equipment - Part 1-2. Safety General Requirements Parallel Standards. Electromagnetic Compatibility Requirements and Testing YY 0607-2007 Medical electrical equipment - Part 2. Particular requirements for safety of nerve and muscle stimulators YY/T 0696-2008 Measurement of output characteristics of nerve and muscle stimulators3 Terms and definitionsThe following terms and definitions defined in YY 0607-2007 apply to this document. 3.1 An instrument for the treatment and adjuvant treatment of patients by electroacupuncture. Usually includes a host, electrode wire and electrode pin connectors, and can also include Set of electrode pins used. 3.2 Electroacupuncture electroacupuncture A therapy, that is, after acupuncture into the muscle tissue to obtain a sense of acupuncture, a small amount of current is applied to the needle, and a double stimulation of acupuncture and electricity is used to assist the treatment of the disease. a method of illness. 3.3 Electrode needle electroacupunctureneedle The acupuncture needle for the electroacupuncture treatment device can be connected to the electrode needle connector to conduct the current output from the therapeutic device to the muscle tissue. 3.4 Electrode needle connector electroacupunctureneedleclamp A device for connecting an electrode wire to an electrode needle, the type of which includes, but is not limited to, a clip type. 3.5 Electrode line electroacupunctureneedleconnector Connect the electrode pin connector to the lead of the output terminal to deliver the output current of the therapy device. Can be composed of multiple segments, including Connector. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY 0780-2025_English be delivered?Answer: Upon your order, we will start to translate YY 0780-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY 0780-2025_English with my colleagues?Answer: Yes. The purchased PDF of YY 0780-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YY 0780-2025?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0780-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |