YY 0718-2009 English PDFUS$239.00 ยท In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. YY 0718-2009: Opthalmic instruments. Retinoscopes Status: Obsolete
Basic dataStandard ID: YY 0718-2009 (YY0718-2009)Description (Translated English): Opthalmic instruments. Retinoscopes Sector / Industry: Medical Device & Pharmaceutical Industry Standard Classification of Chinese Standard: C40 Classification of International Standard: 11.040.70 Word Count Estimation: 6,610 Date of Issue: 2009-06-16 Date of Implementation: 2010-12-01 Quoted Standard: GB 9706.1-2007; ISO 15004-1 Adopted Standard: ISO 12865-2006, IDT Regulation (derived from): Industry standard filing Notice 2009 No. 9 Issuing agency(ies): State Food and Drug Administration Summary: This standard provides for the objective measurement of the human eye refractive errors strip light retinoscope and point-like light retinoscope minimum requirements and test methods. This standard and ISO 15004-1 if different, the standard priority in ISO 15004-1. YY 0718-2009: Opthalmic instruments. Retinoscopes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Opthalmic instruments.Retinoscopes ICS 11.040.70 C40 People's Republic of China pharmaceutical industry standards YY 0718-2009/ISO 12865.2006 Retinoscope ophthalmic instruments (ISO 12865.2006, IDT) Posted 2009-06-16 2010-12-01 implementation State Food and Drug Administration issued ForewordThis standard is equivalent to international standard ISO 12865.2006 "retinoscope ophthalmic instruments." For ease of use, this standard made the following editorial changes. a) "this International Standard" be replaced by "this standard"; b) with a decimal point, instead of as a decimal comma ",". ","; c) Remove the preface to international standards. This standard by the national medical and optical instruments Standardization Technical Committee and centralized. This standard was drafted. State Food and Drug Administration Hangzhou Medical Device Quality Supervision and Inspection Center. The main drafters of this standard. Wang Jingtao, JIA Xiao Hang Feng Qin. YY 0718-2009/ISO 12865.2006 Retinoscope ophthalmic instruments1 ScopeThe ISO 15004-1 standard and common provisions for objective measurement of the eye refractive errors ribbon optical retinoscope and point-like light retinoscopy mirror Minimum requirements and test methods. The ISO 15004-1 standard and if there is, the present standard in preference to ISO 15004-1.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) ISO 15004-1 ophthalmic instruments General requirements and test methods3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Objective assessment of the refractive error eye and retinal reflection cross over the pupil when the displacement of ophthalmic instruments by specular reflection beam. NOTE. retinoscope typically include analysis by the center through light microscopy or optical mirror projection system, observation system and power supply. 3.2 Can produce a focal length and orientation of the adjustable rectangular cross-section beam retinoscope. 3.3 Capable of generating a bundle of approximately circular cross-section beam retinoscope. NOTE. Focus image can be adjusted.4 Requirements4.1 General requirements Retinoscope should meet the general requirements specified in ISO 15004-1. Retinoscope shall comply with the requirements of 4.2 to 4.3. These requirements should be verified in accordance with the provisions of Chapter 5. 4.2 Optical and mechanical requirements Retinoscope shall comply with the requirements of Table 1. YY 0718-2009/ISO 12865.2006 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY 0718-2009_English be delivered?Answer: Upon your order, we will start to translate YY 0718-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY 0718-2009_English with my colleagues?Answer: Yes. The purchased PDF of YY 0718-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |