YY 0322-2018: High frequency electrocautery therapy equipment
Status: Obsolete

YY 0322: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY 0322-2018239 Add to Cart 3 days High frequency electrocautery therapy equipment Obsolete
YY/T 0322-2018159 Add to Cart 3 days High frequency electrocautery therapy equipment Valid
YY 0322-2009319 Add to Cart 3 days High frequency fulguration therapy equipment Obsolete
YY 0322-2000759 Add to Cart 5 days High frequency electrocautery therapy equipment Obsolete

Similar standards

YY 0778   YY 0950   YY/T 1095   YY/T 0323   YY/T 0324   YY 0323   

Basic data

Standard ID: YY 0322-2018 (YY0322-2018)
Description (Translated English): High frequency electrocautery therapy equipment
Sector / Industry: Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard: C42
Classification of International Standard: 11.040.60
Word Count Estimation: 6,612
Date of Issue: 2018-09-28
Date of Implementation: 2020-04-01
Older Standard (superseded by this standard): YY 0322-2009
Quoted Standard: GB 9706.1-2007; GB 9706.4-2009; GB 9706.15-2008; GB/T 14710-2009; GB/T 16886.1-2011; YY 0505-2012; YY 1057
Regulation (derived from): State Drug Administration Announcement No. 72 of 2018
Issuing agency(ies): State Drug Administration
Summary: This standard specifies the terms and definitions, composition, requirements, and test methods of the high frequency electrocautery therapeutic apparatus. This standard applies to the high frequency electrocautery treatment instrument defined in 3.1 (hereinafter referred to as the therapeutic device).

YY 0322-2018: High frequency electrocautery therapy equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High frequency electrocautery therapy equipment ICS 11.040.60 C42 People's Republic of China Pharmaceutical Industry Standard Replace YY 0322-2009 High frequency electrocautery therapeutic apparatus Published on.2018-09-28 2020-04-01 implementation State Drug Administration issued

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces YY 0322-2009 "High Frequency Electrocautery Therapy Apparatus". Compared with YY 0322-2009, except for editorial modifications The changes are as follows. --- Revised the definition of high frequency electrocautery therapy device (see 3.1, 3.1 of.2009 edition); --- Modified the output power requirements (see 5.2,.2009 version 4.2.2); ---Modified the requirements of the output indicating device (see 5.4, 4.2.4 of the.2009 edition); --- Increased standby noise, random file requirements (see 5.5, 5.8); ---Modified the requirements for electromagnetic compatibility (see 5.11, 4.4 of the.2009 edition); --- Removed the definition of load impedance and output (3.2, 3.3 of.2009 edition); --- Removed the requirements of the output controller (2009 version 4.2.5). Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard was proposed by the State Drug Administration. This standard is under the jurisdiction of the National Medical Electrical Equipment Standardization Technical Committee Physical Therapy Equipment Subcommittee (SAC/TC10/SC4). This standard was drafted. Tianjin Medical Device Quality Supervision and Inspection Center. The main drafters of this standard. Liu Bo, Li Yanan, Qi Lijing, Han Mo, Ji Caiyan, Wu Gang. The previous versions of this standard were released as follows. ---YY 0322-2000, YY 0322-2009. High frequency electrocautery therapeutic apparatus

1 Scope

This standard specifies the terms and definitions, composition, requirements, and test methods of the high frequency electrocautery therapeutic apparatus. This standard applies to the high frequency electrocautery treatment instrument defined in 3.1 (hereinafter referred to as the therapeutic device).

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1.1988, IDT) GB 9706.4-2009 Medical electrical equipment - Part 2-2. Particular requirements for safety of high-frequency surgical equipment (IEC 60601-2-2. 2006, IDT) GB 9706.15-2008 Medical electrical equipment - Part 1-1. Safety common requirements Parallel standard. Safety of medical electrical systems Seeking (IEC 60601-1-1.2000, IDT) GB/T 14710-2009 Environmental requirements and test methods for medical appliances GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1. Evaluation and testing in the process of risk management (ISO 10993-1.2009, IDT) YY 0505-2012 Medical electrical equipment - Part 1-2. Safety common requirements Parallel standard. Electromagnetic compatibility requirements and testing (IEC 60601-1-2.2004, IDT) YY 1057 medical foot switch general technical conditions

3 Terms and definitions

The following terms and definitions as defined in GB 9706.1-2007 and GB 9706.4-2009 apply to this document. 3.1 Unipolar HF surgical equipment with a rated output power not exceeding 50 W and intended without neutral electrodes.

4 composition

The high frequency electrocautery treatment device is usually composed of a host computer, a surgical accessory, a foot switch, and the like.

5 requirements

5.1 Working frequency The operating frequency error should not exceed ±10% of the nominal value. 5.2 rated output power The rated output of the therapy device should not exceed 50W and the error should not exceed ±20% of the nominal value.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY 0322-2018_English be delivered?

Answer: Upon your order, we will start to translate YY 0322-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY 0322-2018_English with my colleagues?

Answer: Yes. The purchased PDF of YY 0322-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY 0322-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0322-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.