Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 990.2-2014 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 990.2-2014: Methods for chemical analysis of copper matte. Part 2: Determination of gold and silver contents. Atomic absorption spectrmetry and fire assay method
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 990.2-2014259 Add to Cart 3 days Methods for chemical analysis of copper matte. Part 2: Determination of gold and silver contents. Atomic absorption spectrmetry and fire assay method Valid

Similar standards

YS/T 953.9   GB/T 3884.2   GB/T 3884.1   YS/T 990.11   YS/T 990.1   YS/T 990.10   

Basic data

Standard ID: YS/T 990.2-2014 (YS/T990.2-2014)
Description (Translated English): Methods for chemical analysis of copper matte. Part 2: Determination of gold and silver contents. Atomic absorption spectrmetry and fire assay method
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H13
Classification of International Standard: 77.120.30
Word Count Estimation: 10,114
Date of Issue: 10/14/2014
Date of Implementation: 4/1/2015
Regulation (derived from): People's Republic of China Ministry of Industry and Information Technology Notice 2014 No. 63; Industry Standard Filing Notice 2014 No. 12 (Overall No. 180)
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This Standard specifies the method for determination of copper matte silver content. This section applies to the determination of copper in ice silver content. 1 measuring range of Ag 20.0g/t ~ 500.0 g/t; Method 2 measuring range of Au1.00g/t ~ 50.00g/t;

YS/T 990.2-2014: Methods for chemical analysis of copper matte. Part 2: Determination of gold and silver contents. Atomic absorption spectrmetry and fire assay method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of copper matte Part 2. Determination of gold and silver contents Atomic absorption spectrmetry and fire assay method ICS 77.120.30 H13 People's Republic of China Nonferrous Metals Industry Standard Matte chemical analysis Part 2. Gold and silver content determination Atomic absorption spectroscopy and fire assay Part 2. Determinationofgoldandsilvercontents- Issued on. 2014-10-14 2015-04-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 990 "Methods for chemical analysis of copper matte" is divided into 18 parts. --- Part 1. Determination of copper content iodometry; --- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay; --- Part 3. Determination of sulfur content - Gravimetric method and combustion titration method; --- Part 4. Determination of the amount of bismuth atomic absorption spectrometry; --- Part 5. Determination of the amount of fluorine ion selective electrode method; --- Part 6. Determination of lead content - Atomic absorption spectrometry and Na2EDTA titration; --- Part 7. Determination of cadmium content - Atomic absorption spectrometry; --- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry, diethyl dithiocarbamate spectrophotometry silver And potassium bromate titration; --- Part 9. Determination of iron content dichromate method; --- Part 10. Determination of silicon dioxide content molybdenum blue spectrophotometric method and silicon potassium fluoride titration; --- Part 11. Determination of the amount of nickel atom absorption spectrometry; --- Part 12. Determination of the amount of chromium oxide of aluminum Azure S Spectrophotometry; --- Part 13. Determination of magnesium oxide content - Atomic absorption spectrometry; --- Part 14. Determination of the amount of zinc atomic absorption spectrometry and Na2EDTA titration; --- Part 15. Determination of antimony content - Atomic absorption spectrometry; --- Part 16. Determination of mercury content - Cold atomic absorption spectrometry; --- Part 17. Determination of the amount of cobalt atomic absorption spectrometry; --- Part 18. lead, zinc, nickel, arsenic, bismuth, antimony, calcium, magnesium, cadmium, cobalt content - Inductively coupled plasma atomic emission spectrometry. This section YS/T Part 2 990. The silver content of the cross-section part 1 for arbitration. This section drafted in accordance with GB/T 1.1-2009 given rules. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Zhongtiaoshan Nonferrous Metals Group Co., Ltd. Daye Nonferrous Metals Group Holdings Limited. This section is drafted. Daye Nonferrous Metals Group Holdings Limited. The unit participated in the drafting Part 1. In the mountains of Nonferrous Metals Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy, Tongling Nonferrous Metals collection Group Holdings Ltd., Yunnan Copper Co., Ltd., Zijin Mining Co., Ltd., Shandong Yoshimitsu Copper Co., Ltd., Hunan Nonferrous Metals RESEARCH Hospital study, Baiyin Nonferrous Group Co., Ltd., Guangzhou Nonferrous Metal Research Institute, Shandong constant state Smelting Co., Ltd., the gold Lingnan Shaoguan Smelter Refinery, Smelting Co., Ltd. Hangzhou Fuchun River. This section participated in the drafting Method 2. In the mountains of Nonferrous Metals Group Co., Ltd., Beijing General Research Institute of Mining and Metallurgy, Tongling Nonferrous Metals collection Group Holdings Ltd., Yunnan Copper Co., Ltd., Zijin Mining Co., Ltd., Hunan Nonferrous Metal Research Institute, Baiyin Nonferrous Metals Group shares Ltd., Guangzhou Nonferrous Metal Research Institute, Shandong constant state Smelting Co., Ltd., the gold Lingnan Shaoguan smelter, smelting Fuchun River in Hangzhou has Limited. The main drafters of this Part 1. Hujun Kai Guo Jing, Feng Yuan, Li Feng, Zhang Zhongxiang, Li Ruiling, Yang Deli, the whole East, Zhang Liao, Xiao new, Feng Zhenhua, Wang Haoying, Liqin Mei, Laiqiu Xiang, Huang Ping, million pairs, Magofuku red. The main drafters of this section Method 2. Wang Yongbin, Xiongmei Yu, Feng new, Leichun Ming, Zhang Yu, Wang Guangming, Li Bing, the whole East, Dai Fengying, Zhang Liao, Wanghao Ying, Feng Zhenhua, and from Shao, Zhang Hongxian, Yangjian Bing, Magofuku red. Matte chemical analysis Part 2. Gold and silver content determination Atomic absorption spectroscopy and fire assay

1 Scope

This section YS/T 990 specifies the method for determination of copper matte silver content. This section applies to the determination of copper in ice silver content. The method of measurement in the range of 1 Ag20.0g/t ~ 500.0g/t; Method 2 measurement range It is Au1.00g/t ~ 50.00g/t; Ag50.0g/t ~ 3700.0g/t. 2. Method 1. atomic absorption spectrometry 2.1 Method summary Sample with nitric acid, perchloric acid dissolved in dilute hydrochloric acid medium, by atomic absorption spectrometer wavelength at 328.1nm, air - acetylene fire Flame measuring the absorbance of silver, net of background absorption, according to the standard curve method to calculate the amount of silver. 2.2 Reagents Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 2.2.1 Ammonium hydrogen fluoride. 2.2.2 hydrochloric acid (ρ = 1.19g/mL). 2.2.3 hydrochloric acid (19). 2.2.4 nitric acid (ρ = 1.42g/mL). 2.2.5 nitric acid (11). 2.2.6 perchloric acid (ρ = 1.67g/mL). 2.2.7 Silver standard stock solution. Weigh 0.5000g metallic silver (wAg≥99.99%) in 200mL beaker, add 20mL of nitric acid (2.2.5), heated until completely dissolved, cooled to room temperature and transferred to 1000mL brown volumetric flask, diluted with water, no chlorine ions to the mark, and mix. This solution 1mL containing 500μg silver. 2.2.8 Silver standard solution. Pipette 5.00mL silver standard stock solution (2.2.7) in 250mL flask, diluted with hydrochloric acid (2.2.3) to Volume, and mix. This solution 1mL containing 10μg silver. 2.3 Instrument Atomic absorption spectrometer, with a silver hollow-cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. in the measurement sample solution matrix consistent solution, features silver concentration should be less than 0.018μg/mL. --- Precision. measuring the absorbance of 11 with the highest concentration of the standard, the standard deviation should not exceed the average absorbance of 1.0%, with The lowest concentration of standard solution (not "zero" standard solution) measuring the absorbance of 11 times, the standard deviation should not exceed the maximum concentration standard 0.5% average standard solution absorbance. --- Linear curve. The curve is divided into five sections according to concentration, than the absorbance difference between the highest and the lowest segment of the segment absorbance difference Not less than 0.85.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 990.2-2014_English be delivered?

Answer: Upon your order, we will start to translate YS/T 990.2-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 990.2-2014_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 990.2-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.