YS/T 928.4-2013 PDF EnglishUS$170.00 · In stock · Download in 9 seconds
YS/T 928.4-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsYS/T 928.4-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST928.4-2013 YS NONFERROUS INDUSTRY STANDARD ICS 77.120.60 H 13 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide - Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum, Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric Issued on. OCTOBER 17, 2013 Implemented on. MARCH 1, 2014 Issued by. Ministry of Industry and Information Technology of the People’s Republic of China Table of ContentsForeword... 3 1 Scope... 4 2 Method Summary... 4 3 Reagents... 5 4 Instrument... 6 5 Analytical Procedures... 7 6 Calculation and Expression of Analysis Results... 8 7 Precision... 8 8 Test Report... 10ForewordYS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide includes the following six parts. ---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry; ---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric; ---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled Plasma Atomic Emission Spectrometric; ---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum, Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric; ---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass Spectrometry; ---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography. This is Part 4 of YS/T 928. This Part was drafted in accordance with the rules provided in GB/T 1.1-2009. This Standard shall be under the jurisdiction of National Technical Committee 243 on Nonferrous Metals of Standardization Administration of China (SAC/TC 243). The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining & Metallurgy. The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling Technology Co., Ltd. The participating drafting organizations of this Part. Zhejiang Huayou Cobalt Co., Ltd.; Tianjin Maolian Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co., Ltd. The main drafters of this Part. Guo Peiqing, Li Changdong, Qin Fanglin, Yu Haijun, Qiu Ping, Wu Yahui, Xie Bohua, Zhang Ping, Pan Haiyun, Ren Xingting. Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide - Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum, Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric1 ScopeThis Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table 1 for the determination scope. Table 1 -- Determination Scope2 Method SummaryUse hydrochloric acid to dissolve the test portion and adopt an inductively coupled plasma atomic emission spectrometer to directly conduct the determination. In accordance with the working curve method, calculate the concentration of each element. Express the determination results in mass fraction. Element Determination Scope (w)/%3 ReagentsAll reagents used in this Part are of top-grade purity, and only pure water with an electrical resistivity of not less than 18.2 M cm shall be used in the analysis. 3.1 Hydrochloric acid (ρ = 1.19 g/mL). 3.2 Nitric acid (ρ = 1.42 g/mL). 3.3 Hydrochloric acid (1 + 1). 3.4 Nitric acid (1 + 1). 3.8 Copper standard stock solution. weigh-take 0.2000 g of pure copper (wCu 99.99%) in a 300 mL beaker, slowly add 30 mL of nitric acid (3.4), use a watch glass to cover it; at a low temperature, dissolve it and drive out nitrogen oxides, then, remove and cool it. Use water to wash the watch glass and beaker wall. Transfer to a 1,000 mL volumetric flask, use water to dilute to the scale and mix it well. 1 mL of this solution contains 200 g of copper. 3.13 Aluminum, magnesium, calcium, copper, iron and zinc standard solutions. accurately transfer-take 10.00 mL of the standard stock solutions (3.5, 3.6, 3.7, 3.8, 3.9 and 3.10) in a 200 mL volumetric flask. Use water to dilute to the scale and mix it well. 1 mL of this solution contains 10 g of aluminum, magnesium, calcium, copper, iron and zinc. 3.14 Sodium standard solution. accurately transfer-take 10.00 mL of the standard stock solution (3.11) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 g of sodium. 3.15 Silicon standard solution. accurately transfer-take 10.00 mL of the standard stock solution (3.12) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 g of silicon.4 InstrumentIn terms of the inductively coupled plasma atomic emission spectrometer, the spectral lines of the various element are shown in Table 2; the working parameters of the instrument for sodium determination are shown in Table 3; the working parameters of the instrument for the determination of other elements are shown in Table 4.5 Analytical Procedures5.1 Test Portion Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g. 5.2 Blank Test Along with the specimen, conduct the blank test. 5.3 Treatment of Test Portion Place the test portion (5.1) in a 100 mL polytetrafluoroethylene beaker, add 20 mL of hydrochloric acid (3.3), use a watch glass to cover it, dissolve it with slight heat. After the test portion is completely dissolved, remove it, cool it, then, use water to wash the watch glass and beaker wall. Transfer it to a 200 mL volumetric flask, use water to dilute to the scale and mix it well. On an inductively coupled plasma atomic emission spectrometer, conduct the determination. 5.4 Drawing of Working Curve7 Precision7.1 Repeatability Under repeatability conditions, obtain the determined values of two independent test results. Within the average value range provided in Table 5, the absolute difference between the two test results does not exceed the repeatability limit (r), and the circumstances of exceeding the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the linear interpolation method and the extrapolation method in accordance with the data in Table 5.8 Test ReportThe test report shall include the following content. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of YS/T 928.4-2013 be delivered?Answer: The full copy PDF of English version of YS/T 928.4-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of YS/T 928.4-2013_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 928.4-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YS/T 928.4-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of YS/T 928.4-2013?A step-by-step guide to download PDF of YS/T 928.4-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "YS/T 928.4-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |