YS/T 923.2-2024 English PDFYS/T 923.2: Historical versions
Basic dataStandard ID: YS/T 923.2-2024 (YS/T923.2-2024)Description (Translated English): (Chemical analysis method for high purity bismuth - Part 2: Determination of trace impurity element content - Glow discharge mass spectrometry) Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H18 Classification of International Standard: 77.120.99 Date of Issue: 2024-10-24 Date of Implementation: 2025-05-01 Older Standard (superseded by this standard): YS/T 923.2-2013 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the method for determining the content of trace impurity elements in high-purity bismuth by glow discharge mass spectrometry. This standard is applicable to the determination of the content of trace impurity elements in high-purity bismuth. YS/T 923.2-2013: Methods for chemical analysis of high purity bismuth. Part 2: Determination of trace impurity elements content. Glow discharge mass spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of high purity bismuth Part 2. Determination of trace impurity elements content Glow discharge mass spectrometry ICS 77.120.99 H13 People's Republic of China Nonferrous Metals Industry Standard Methods for chemical analysis of high purity bismuth Part 2. Determination of trace element content of Glow Discharge Mass Spectrometry Part 2. Determinationoftraceimpurityelementscontent- Issued on. 2013-10-17 2014-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 923 "purity bismuth chemical analysis method" is divided into two parts. --- Part 1. copper, lead, zinc, iron, silver, arsenic, tin, cadmium, magnesium, chromium, aluminum, gold and nickel content - Inductively Coupled Plasma Mass Spectrometry --- Part 2. Determination of trace element contents of glow discharge mass spectrometry This section YS/T Part 2 923. This section drafted in accordance with GB/T 1.1-2009 given rules. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Beijing Nonferrous Metal Research Institute. This section involved in the drafting unit. Jinchuan Group Co., Ltd., Dongfang Electric Group Co., Ltd. Emei Semiconductor Materials. The main drafters of this section. Li Po City, Liu Ying, Sun Zeming, Tong Jian, Li Jidong, Zang Muwen, Li Na, ZHANG Jin, Zhaoyong Shan, Zhangjiang Feng, Qiu Ping, Qinfang Lin, Wen-ying, Wang Panfeng. Methods for chemical analysis of high purity bismuth Part 2. Determination of trace element content of Glow Discharge Mass Spectrometry1 ScopeYS/T of the provisions of section 923 of the determination of trace elements in high purity bismuth content, the determination of elements in Table 1. This section applies to the determination of trace elements in high purity bismuth content. Determination of the elements in the range of 5.0μg/kg ~ 5000μg/kg.2 principle of the methodSample as a cathode glow discharge in argon atmosphere, and the surface thereof is sputtered atoms from the sample into the glow discharge plasma Ionized and then is introduced into the mass spectrometer for measurement. In each element isotope mass number punishable by default scan points and the integration time The corresponding peak integration, the resulting area is the peak intensity. In the absence of a standard sample, according to the spirit of the instrument relative to the computer software "typical Sensitivity factor "automatically calculate the mass fraction of each element; when the standard sample is required by the sample in the same assay conditions, from Under the sub-source structure and the test conditions of the standard sample was determined by independent relative sensitivity factor, the application of the relative sensitivity factor calculation The mass fraction of the elements.3 Reagents and materialsUnless otherwise indicated, the reagents used in the analysis are excellent pure; water used as a water. 3.1 ethanol. 3.2 Argon (purity ≥99.999%). 3.3 nitric acid (19). 3.4 bismuth standard sample, measured elements mass fraction of between 50μg/kg ~ 500μg/kg. 3.5 Background monitoring instrument samples tested elements requires more than the mass fraction of less than 10 times the sample under test.4 Instrument4.1 high resolution glow discharge mass spectrometer, under the resolution mode resolution of up to 3000 to 4000, high-resolution mode resolution Rate of up to 9,000 to 10,000. 4.2 Each element isotope mass resolution and select Table 1. Requirements base 209Bi the measured peak strength of not less than 1 × 108cps, peak shape to meet the resolution requirements. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 923.2-2024_English be delivered?Answer: Upon your order, we will start to translate YS/T 923.2-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 923.2-2024_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 923.2-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 923.2-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 923.2-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |