Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 805-2012359 Add to Cart 3 days Chemical analysis method for rare earth in aluminium and aluminium alloys. Determination of total rare earth by chemical analysis Obsolete

Similar standards

GB/T 7999   YS/T 600   GB/T 14849.2   YS/T 872   YS/T 420   YS/T 806   

Basic data

Standard ID: YS/T 805-2012 (YS/T805-2012)
Description (Translated English): Chemical analysis method for rare earth in aluminium and aluminium alloys. Determination of total rare earth by chemical analysis
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H12
Classification of International Standard: 77.120.10
Word Count Estimation: 9,981
Regulation (derived from): Ministry of Industry and Information Technology Bulletin No. 55 of 2012; industry standard filing Notice 2013 No. 1 (Total No. 157);
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the aluminum and aluminum alloys Determination of total rare earth cerium group method. This standard This standard applies to aluminum and aluminum alloys Determination of total rare earth cerium group. Determination range of 0. 0

YS/T 805-2012: Chemical analysis method for rare earth in aluminium and aluminium alloys. Determination of total rare earth by chemical analysis


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis method for rare earth in aluminium and aluminium alloys.Determination of total rare earth by chemical analysis ICS 77.120.10 H12 People's Republic of China Nonferrous Metals Industry Standard Aluminum and aluminum alloys of rare earth analysis methods Chemical analysis method for the determination of rare earth content Issued on. 2012-11-07 2013-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized. This standard specifies two test methods, namely Method One. Tribromoarsenazo method and the second method. Fluorescence Spectrometry. This standard is drafted by. Baotou Aluminum Co., Ltd. Participated in the drafting of this standard. Aluminum Corporation of China Zhengzhou Research Institute, Aluminum Corporation of China Henan Branch. The main drafters of this standard. Jian-Hua Jin, Zhao Hongsheng, Li win glory, Zhang Xiaoping, Xingge Bin, Chen Qinghua, Guo Yanping, Yunxia, quiet, Kuang Yuyun, Xuan Hu, Ai Zhen, Bai Pengcheng, Bai Wenjing, Yi Hua, Sun Yong. Aluminum and aluminum alloys of rare earth analysis methods Chemical analysis method for the determination of rare earth content Method One. Tribromoarsenazo spectrophotometry

1 Scope

This standard specifies the method for determination of aluminum and aluminum alloys of rare earth cerium group. The standard of the present method is applicable to the determination of total rare earth aluminum in aluminum and cerium group. Measurement range of 0.050% - 0.400%. This standard does not apply to the present method for the determination of aluminum and aluminum alloys of rare earth cerium group containing yttrium group rare earth.

2 Method summary

The sample is dissolved in hydrochloric acid, hydrochloric acid - oxalic acid medium with hydrogen peroxide and ethanol elimination of titanium (Ⅳ) and iron (Ⅲ) interference, in about 1mol/L HCl medium, rare earth and cerium group Tribromoarsenazo generate stable blue-violet complex, in the spectrophotometer at a wavelength of 634nm Measuring the absorbance.

3 Reagents

3.1 Hydrogen peroxide (p is 1.11g/cm3). 3.2 hydrochloride (11). 3.3 ethanol. 3.4 Hydrogen peroxide (595). 3.5 oxalate (H2C2O4 · 2H2O) solution (80g/L). 3.6 Tribromoarsenazo solution (0.25g/L). 3.7 aluminum solution (4mg/mL). Weigh 4.00g pure aluminum (≥99.9%, excluding rare earth elements) in 500mL beaker was added in total 100mL volume hydrochloric acid (3.2), low-temperature heating until complete dissolution and cooled. Moved into 1000mL volumetric flask, dilute to the mark, Mix well. 3.8 Storage cerium standard solution. Weigh 0.6142g pre-ignition 30min at 800 ℃ ~ 850 ℃, rise in a desiccator to cool to room temperature Ceria ( > 99.9%) were placed in a beaker, was added 5mL perchloric acid (1 1), 2mL of hydrogen peroxide (3.1), cover sheet pan, low temperature heating To cerium oxide completely dissolved, evaporated to near dryness, coolish. Was added 50mL of hydrochloric acid (3.2), 6 drops of hydrogen peroxide (3.1), heated to boiling, dissolved salts Class, so that decomposition of hydrogen peroxide is completely cooled. Transferred to 500mL volumetric flask, add 35mL of hydrochloric acid (3.2), dilute to the mark, mix uniform. 1mL solution containing 1mg cerium. Note. In this standard assay conditions, Tribromoarsenazo complex equal amounts of cerium and other rare earth cerium group agreed absorbance, it can be used in place of cerium Cerium RE for standard. Cerium 3.9 Standard Solution A. Pipette 10.00mL cerium standard stock solution (3.8) in 500mL volumetric flask, was added 40mL of hydrochloric acid (3.2), dilute to the mark and mix. This solution 1mL containing 20.0μg cerium. 3.10 cerium standard solution B. Pipette 10.00mL cerium standard solution A (3.9) in 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 2μg cerium (used when existing service).
......

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 805-2012_English be delivered?

Answer: Upon your order, we will start to translate YS/T 805-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 805-2012_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 805-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.