YS/T 74.4-2010 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 74.4-2010: Methods of chemical anaysis of cadmium. Part 4: Determination of lead content. Flame atomic absorption spectrometry Status: Valid YS/T 74.4: Historical versions
Basic dataStandard ID: YS/T 74.4-2010 (YS/T74.4-2010)Description (Translated English): Methods of chemical anaysis of cadmium. Part 4: Determination of lead content. Flame atomic absorption spectrometry Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.120.70 Word Count Estimation: 8,868 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Older Standard (superseded by this standard): YS/T 74.4-1994 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the amount of lead cadmium determination. This standard applies to the determination of the amount of lead cadmium. Measuring range: 0. 0005% 0. 055%. YS/T 74.4-2010: Methods of chemical anaysis of cadmium. Part 4: Determination of lead content. Flame atomic absorption spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods of chemical anaysis of cadmium.Part 4. Determination of lead content.Flame atomic absorption spectrometry ICS 77.120.70 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 74.4-1994 Methods for chemical analysis of cadmium Part 4. Determination of lead content Flame Atomic Absorption Spectrometry Part 4. Determinationofleadcontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 74-2010 "cadmium chemical analysis method" is divided into 11 parts. --- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of antimony content hydride generation - atomic fluorescence spectrometry; --- Part 3. Determination of nickel content by electrothermal atomic absorption spectrometry; --- Part 4. Determination of lead content by flame atomic absorption spectrometry; --- Part 5. Determination of the amount of copper diethyl dithiocarbamate spectrophotometry lead; --- Part 6. Determination of zinc content - Flame atomic absorption spectrometry; --- Part 7. Determination of iron content of 1,10 phenanthroline spectrophotometry; --- Part 8. Determination of thallium content of crystal violet spectrophotometry; --- Part 9. Determination of tin content by hydride generation - atomic fluorescence spectrometry; --- Part 10. Determination of the amount of silver by flame atomic absorption spectrometry; --- Part 11. Inductively coupled plasma atomic arsenic, antimony, nickel, lead, copper, zinc, iron, thallium, tin and silver content of the emitted light Spectroscopy. This is Part 4. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of YS/T 74.4-1994 "cadmium chemical analysis by flame atomic absorption spectrometric method for the determination of lead content," this part of the original standard Quasi compared to the main changes are as follows. --- Text format has been modified; --- Complements the precision, quality assurance and control provisions; --- Increase the warning prompt; --- Increasing the test report clause. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. MCC Huludao Nonferrous Metals Group Co., Ltd. Participated in the drafting of this section. Shenzhen Lingnan Nonferrous Metals Co., Ltd. Shaoguan Smelter, Zhuzhou Smelter Group Co. Shares The company, Henan Yuguang Gold & Lead Co., Ltd. The main drafters of this section. Sen Chang Shou, Xi Hongjie, Li Xia, Gu Li, Hu Zehui, Cai, Fang. This part of the standard replaces the previous editions are. --- YS/T 74.4-1994; --- GB/T 2129-1980. Methods for chemical analysis of cadmium Part 4. Determination of lead content Flame Atomic Absorption Spectrometry Warning --- Use this section a person shall be regular laboratory work experience, and have the use of atomic absorption spectrophotometer Skills, in strict accordance with safety procedures atomic absorption spectrophotometer operation.1 ScopeYS/T of the provisions of section 74 of the method for the determination of cadmium in lead content. This section applies to the determination of cadmium in lead content. Measurement range. 0.0005% to 0.055%.2 principle of the methodSample decomposition with nitric acid, ferric hydroxide as a carrier, co-precipitation of cadmium and enrichment of trace lead. In dilute nitric acid medium, using air - B Alkyne flame atomic absorption spectrometer to measure the absorbance at a wavelength of 283.3nm, the amount of lead is obtained using standard curve method. The amount of lead (wPb) ≥0.01% of the sample, without co-precipitation and direct determination in dilute nitric acid medium.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or equivalent purity. 3.1 nitrate (ρ1.42g/mL), pure class distinctions. 3.2 Ammonia (ρ0.90g/mL), pure class distinctions. 3.3 nitric acid (11). 3.4 ammonia (120). 3.5 ferric nitrate solution. Weigh 28.9g of ferric nitrate [Fe (NO3) 3 · 9H2O] (wPb≤0.0001%) was dissolved in 100mL nitric acid (1 27). This solution 1mL contains 40mg iron. 3.6 Cadmium matrix solution. Weigh 10.00g metal cadmium (wCd≥99.99% and wPb≤0.0001%), placed in 400mL beaker, graded Was added 40mL of nitric acid (3.3), After vigorous reaction, the oxides of nitrogen purge heating, cooling. Transferred to 100mL volumetric flask, diluted with water To the mark, and mix. This solution 1mL containing 100mg cadmium. 3.7 lead standard stock solution. Weigh 1.0000g cleaned surface of metallic lead (wPb≥99.99%) placed in 250mL beaker, add 20mL of nitric acid (3.3), is completely dissolved in a low temperature, nitrogen oxides rid boiling, remove the cooling. Moved into 1000mL volumetric flask with water Dilute to volume, and mix. This solution 1mL containing 1mg lead. 3.8 Lead standard solution. Pipette 50.00mL lead standard stock solution (3.7) in 500mL flask, add 10mL of nitric acid (3.3), Dilute with water to volume, and mix. This solution 1mL containing 100μg lead.4 InstrumentAtomic absorption spectrometer, with a lead hollow cathode lamp. Under optimum working conditions, who can reach the following indicators are, can be used. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 74.4-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 74.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 74.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 74.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 74.4-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 74.4-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |