YS/T 74.1-2010 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 74.1-2010: Methods for chemical analysis of cadmium. Part 1: Determination of arsenic content-Hydride generation-atomic fluorescence spectrometry Status: Valid YS/T 74.1: Historical versions
Basic dataStandard ID: YS/T 74.1-2010 (YS/T74.1-2010)Description (Translated English): Methods for chemical analysis of cadmium. Part 1: Determination of arsenic content-Hydride generation-atomic fluorescence spectrometry Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.120.70 Word Count Estimation: 6,632 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Older Standard (superseded by this standard): YS/T 74.1-1994 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the amount of arsenic cadmium determination. This standard applies to the determination of the amount of arsenic cadmium. Measuring range: 0. 00020% to 0. 0025 % YS/T 74.1-2010: Methods for chemical analysis of cadmium. Part 1: Determination of arsenic content-Hydride generation-atomic fluorescence spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of cadmium.Part 1. Determination of arsenic content-Hydride generation-atomic fluorescence spectrometry ICS 77.120.70 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 74.1-1994 Methods for chemical analysis of cadmium Part 1. Determination of arsenic content Hydride Generation - Atomic Fluorescence Spectrometry Part 1. Determinationofarseniccontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 74-2010 "cadmium chemical analysis method" is divided into 11 parts. --- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of antimony content hydride generation - atomic fluorescence spectrometry; --- Part 3. Determination of nickel content by electrothermal atomic absorption spectrometry; --- Part 4. Determination of lead content by flame atomic absorption spectrometry; --- Part 5. Determination of the amount of copper diethyl dithiocarbamate spectrophotometry lead; --- Part 6. Determination of zinc content - Flame atomic absorption spectrometry; --- Part 7. Determination of iron content of 1,10 phenanthroline spectrophotometry; --- Part 8. Determination of thallium content of crystal violet spectrophotometry; --- Part 9. Determination of tin content by hydride generation - atomic fluorescence spectrometry; --- Part 10. Determination of the amount of silver by flame atomic absorption spectrometry; --- Part 11. Inductively coupled plasma atomic arsenic, antimony, nickel, lead, copper, zinc, iron, thallium, tin and silver content of the emitted light Spectroscopy. This is Part 1. This section drafted in accordance with GB/T 1.1-2009 given rules. "Spectrophotometric determination of cadmium molybdenum blue spectrophotometric method for chemical analysis of arsenic amount" in this section instead of YS/T 74.1-1994, this part of the original criteria Ratio, the main changes are as follows. --- Analytical methods to hydride generation - atomic fluorescence spectrometry; --- The detection limit of 0.0005% decurrent 0.00020%; --- Increase the warning prompt; --- Increasing the test report clause. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. MCC Huludao Nonferrous Metals Group Co., Ltd. Participated in the drafting of this section. Beijing Mining Research Institute, Shaanxi Dongling Smelting Co., Ltd., Liaoning Entry Inspection and Quarantine Bureau. The main drafters of this section. Li Zunyi, Zhao Dan, Liu Limin, seeking Tao Jiang, Li Xue, Li Yan, Dong Xiuwen. This part of the standard replaces the previous editions are. --- YS/T 74.1-1994; --- GB 2133-1980. Methods for chemical analysis of cadmium Part 1. Determination of arsenic content Hydride Generation - Atomic Fluorescence Spectrometry Warning --- Use this section shall be a person experiences regular laboratory work, and have the use of atomic fluorescence spectrometer skills, In strict accordance with safety procedures atomic fluorescence spectrometer operation.1 ScopeYS/T of the provisions of section 74 of the method for the determination of arsenic content in cadmium. This section applies to the determination of arsenic content in cadmium. Measurement range. 0.00020% to 0.0025%.2 principle of the methodSample was dissolved in nitric acid, thiourea - Ascorbic Acid prereduced arsenic, while masking copper, iron and other impurity elements, and hydride generator, arsenic It is reduced to potassium borohydride as hydride with argon gas into the quartz furnace atomizer, the fluorescence intensity measured on the atomic fluorescence spectrometer.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or equivalent purity. 3.1 potassium borohydride. 3.2 hydrochloric acid (ρ1.19g/mL), pure class distinctions. 3.3 nitrate (ρ1.42g/mL), pure class distinctions. 3.4 hydrochloride (11). 3.5 hydrochloride (19). 3.6 nitric acid (11). 3.7 thiourea - ascorbic acid solution. Weigh thiourea, each 25g ascorbic acid dissolved in 500mL of water, the time is now equipped with. 3.8 potassium borohydride solution. Weigh 10g potassium borohydride (3.1) was dissolved in 500mL of potassium hydroxide solution (0.5g/L), filtered spare, with When existing service. 3.9 arsenic standard stock solution. Weigh 0.1320g trioxide (wAs2O3≥99.9%, has been pre-dried in a drier 24h) to 300mL beaker, was added 20mL of sodium hydroxide (10g/L), completely dissolved by heating, addition of hydrochloric acid (3.4) and to slightly cooled, shift Into 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 0.1mg arsenic. Warning. As2O3 toxic, use caution. 3.10 arsenic standard solution. Pipette 2.00mL arsenic standard stock solution (3.9) in 500mL volumetric flask, was added 75mL of hydrochloric acid (3.2), Dilute with water to volume, and mix. This solution 1mL containing 0.4μg arsenic.4 InstrumentAtomic fluorescence spectrometer, with a high-intensity arsenic hollow cathode lamp. Shielding gas and a carrier gas of argon (≥99.99%). Under optimum working conditions, who can achieve the following indicators atomic fluorescence spectrometer can be used. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 74.1-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 74.1-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 74.1-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 74.1-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 74.1-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 74.1-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |