Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 667.4-2009 English PDF

US$249.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 667.4-2009: The testing methods for chemical alumina. Part 4: Determining concentration of arsenic and mercury in 4A zeolite by HG-ICP-AES
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 667.4-2009249 Add to Cart 3 days The testing methods for chemical alumina. Part 4: Determining concentration of arsenic and mercury in 4A zeolite by HG-ICP-AES  

Similar standards

YS/T 575.23   GB/T 23615.1   YS/T 575.24   YS/T 680   YS/T 667.3   YS/T 667.2   

Basic data

Standard ID: YS/T 667.4-2009 (YS/T667.4-2009)
Description (Translated English): The testing methods for chemical alumina. Part 4: Determining concentration of arsenic and mercury in 4A zeolite by HG-ICP-AES
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H30
Classification of International Standard: 71.100.10
Word Count Estimation: 7,794
Date of Issue: 2009-12-04
Date of Implementation: 2010-06-01
Regulation (derived from): MIIT [2009] No. 66
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the 4A zeolite arsenic, mercury method. This standard applies to 4A zeolite arsenic, mercury determination. Measuring range: Arsenic 5 �� 10-5% ~ 5 �� 10-3%, mercury 1 �� 10-5% ~ 5 �� 10-3%.

YS/T 667.4-2009: The testing methods for chemical alumina. Part 4: Determining concentration of arsenic and mercury in 4A zeolite by HG-ICP-AES


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The testing methods for chemical alumina.Part 4. Determining concentration of arsenic and mercury in 4A zeolite by HG-ICP-AES ICS H30 People's Republic of China Nonferrous Metals Industry Standard Chemical alumina chemical analysis methods Part 4 Determination of 4A Zeolite arsenic and mercury content Hydride Generation - inductively coupled plasma emission spectrometry Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 667 "Chemical alumina chemical analysis methods," is divided into four parts. --- Part 1 emits light with aluminum hydroxide filler and quasi boehmite of cadmium, chromium, vanadium content - Inductively coupled plasma Spectroscopy; --- Part 2 generating filler aluminum hydroxide and quasi boehmite arsenic, mercury, lead content was measured hydride - Inductively Coupled Plasma emission spectrometry; --- Part 3 4A zeolite cadmium, chromium, vanadium content - Inductively coupled plasma atomic emission spectrometry; --- Part 4 Determination of 4A Zeolite hydride arsenic, mercury content generation - inductively coupled plasma emission spectrometry. This is Part 4. Appendix A of this section is an informative annex. The non-ferrous metal part by the National Standardization Technical Committee and centralized. Drafting this Part. Aluminum Corporation of China Shandong Branch, China Nonferrous Metals Industry Standards and Metrology Institute for Quality. The main drafters of this section. Zhang Xinyu, Yun-Xia Wang, Chen Jianli. This part certifier. Liyue Ping, Zhaogui Fen. Chemical alumina chemical analysis methods Part 4 Determination of 4A Zeolite arsenic and mercury content Hydride Generation - inductively coupled plasma emission spectrometry

1 Scope

YS/T of the provisions of the section 667 determination 4A zeolite arsenic, mercury content. This section applies to arsenic, mercury determination 4A zeolite. Measuring range. Arsenic 5 × 10-5% ~ 5 × 10-3%; mercury 1 × 10-5% ~ 5 × 10-3%.

2 principle of the method

Sample is dissolved in hydrochloric acid, at a certain acidity, measured elements in the hydride generator enriched through hydrogenation. Then import Argon plasma excitation light source, spectral measurement. To choose effective complexing agent to mask the influence of matrix interference and other elements on the determination.

3 Reagents

Unless otherwise indicated in the analysis using only deionized water or equivalent purity. 3.1 hydrochloric acid 1 + 1 (excellent pure by sub-boiling second distillation). 3.2 arsenic standard solution. This standard stock solution (1mg/mL) provided by the National Research Center. When using the above standard solution (3.1) was diluted 100-fold with hydrochloric acid, diluted standard solution 1mL containing 10μg arsenic. 3.3 mercury standard solution. This standard stock solution (1mg/mL) provided by the National Research Center. When using the above standard solution (3.1) was diluted 100-fold with hydrochloric acid, diluted standard solution 1mL containing 10μg mercury. 3.4 mixed standard solution. accurate Pipette respectively 10.00mL arsenic standard solution (3.2), 10.00mL mercury standard solution (3.3) to 100mL volumetric flask, add 20mL of hydrochloric acid (3.1), and then diluted to the mark with secondary deionized water, and mix. This mixed standard solution of arsenic, Elemental mercury concentration was 1μg/mL. 3.5 aluminum matrix solution. Weigh 13.2350g pure aluminum ( > 99.999%) in the beaker, 250mL of hydrochloric acid (3.1), to a low-temperature heating Dissolve completely. Transferred to 500mL volumetric flask, cooled to room temperature, diluted with deionized water to a secondary volume, and mix. This oxygen-containing solution 1L Aluminum 50g. 3.6 sodium base solution. Weigh 5.08g spectroscopically pure sodium chloride (pre-ignition 1h at 500 ℃ muffle furnace and cooled to room temperature) in a beaker, Deionized water was added 30mL dish cover sheet, after a hot plate until the sample is completely dissolved in, transferred to 100mL volumetric flask, cool to room temperature, In secondary diluted with deionized water to the mark, 1L solution containing 20g sodium. 3.7 10g/L potassium iodide -10g/L ascorbic acid and 50g/L thiourea mixed solution. Weigh 1g of potassium iodide, 1g 5g ascorbic acid and sulfur Urea dissolved in 100mL of water, shake well. 3.8 sodium borohydride solution. Weigh 1.5g of potassium borohydride in 100mL beaker, add 1 to 2 of solid sodium hydroxide, was added 100mL Dissolved in water. This solution 1L sodium boron hydride 15g. 3.9 high purity argon ( > 99.999%).

4 Instrument

Full Spectrum Direct Reading plasma emission spectrometer; hydride generator.

5 Sample

Samples at 105 ℃ ± 5 ℃ oven baking 1h. Placed in a desiccator, cooled to room temperature, and immediately weighed.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 667.4-2009_English be delivered?

Answer: Upon your order, we will start to translate YS/T 667.4-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 667.4-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 667.4-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.