YS/T 602-2017 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 602-2017: Test method for resistivity of zone-refined germaniun ingot using a two-point probe Status: Valid YS/T 602: Historical versions
Basic dataStandard ID: YS/T 602-2017 (YS/T602-2017)Description (Translated English): Test method for resistivity of zone-refined germaniun ingot using a two-point probe Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H21 Classification of International Standard: 77.040 Word Count Estimation: 9,936 Date of Issue: 2017-07-07 Date of Implementation: 2018-01-01 Older Standard (superseded by this standard): YS/T 602-2007 Quoted Standard: GB/T 11071 Regulation (derived from): Ministry of Industry and Information Technology Bulletin 2017 No. 32; Industry Standard Filing Announcement 2017 No. 9 (Total No. 213) Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the test method for the resistivity of the zone melting ingot. YS/T 602-2007: Test method for resistivity of zone-refined germanium ingot using a two-point probe---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Test method for resistivity of zone-refined germanium ingot using a two-point probe ICS 77.040 H21 People's Republic of China Nonferrous Metals Industry Standard Zone melting germanium ingot Resistivity Test Method two probe Posted 2007-11-14 2008-05-01 implementation National Development and Reform Commission issued ForewordAppendix A of this standard is a normative appendix. This standard by the national non-ferrous metals Standardization Technical Committee. This standard by the national non-ferrous metals Standardization Technical Committee and is responsible for interpretation. This standard is mainly drafted by. Huize Dongxing Group Co., Ltd. Assistance in the drafting of this standard. Beijing Nonferrous Metal Research Institute, Yunnan Chihong Zinc and Germanium Co., Ltd., Nanjing Germanium Factory Co., Ltd. the company. Drafters of this standard. East Bowen, Li Hecheng, Zheng Hong, universal Kun, Wu school, Yu Huai, the deed Hongying, Zhang Liping. Zone melting germanium ingot Resistivity Test Method two probe1 ScopeThis standard specifies the DC two probe measuring zone melting germanium ingot resistivity. This standard applies to the measurement GB/T 11071 "zone melting germanium ingot" provides resistivity trapezoidal native boat production zone melting germanium ingot, resistance Measurement range of 0.1Ω · cm ~ 100Ω · cm. Requirements of this standard zone melting germanium ingot ingot measured cross-sectional area along the length of the linear portion of the gradient, and the ingot length must be greater than the cross-section Maximum size and spacing of the probe more than three times.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms of dated references, all subsequent Amendments (not including errata content) or revisions do not apply to this standard. However, according to the study encourages the parties to the agreement Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 11071 zone melting germanium ingot3 Method summary1, FIG germanium ingot ends made ohmic contact, and through direct current I (A), perpendicular to the current direction between the read voltage of two o'clock 1,2 ρ = · S (Ω · cm) (1) Figure 1 two probe method resistivity schematic4 apparatus and equipmentElectromagnetic shielding between 4.1 In order to eliminate parasitic currents near the high-frequency generator in the measurement circuit may be introduced in the resistivity measurement must be between the electromagnetic shielding get on. 4.2 constant temperature and humidity equipment Ensure that the temperature between the inside of electrical resistivity can be stabilized at a temperature of 23 ℃ ± 0.5 ℃, relative humidity less than 70%. 4.3 Thermometer Germanium ingot surface temperature measurement, reading accuracy of ± 0.1 ℃. 4.4 Measuring Instruments 4.4.1 electronic balance (5kg), accurate to 1g, for quality weighing germanium ingot. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 602-2017_English be delivered?Answer: Upon your order, we will start to translate YS/T 602-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 602-2017_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 602-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 602-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 602-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |