YS/T 574.3-2009 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 574.3-2009: Methods for chemical analysis of zirconium powder for electro-vacuum uses. The molybdenum blue spectrophotometric method for determination of silicon Status: Valid YS/T 574.3: Historical versions
Basic dataStandard ID: YS/T 574.3-2009 (YS/T574.3-2009)Description (Translated English): Methods for chemical analysis of zirconium powder for electro-vacuum uses. The molybdenum blue spectrophotometric method for determination of silicon Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H71 Classification of International Standard: 77.120 Word Count Estimation: 6,692 Date of Issue: 2009-12-04 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): YS/T 574.3-2006 Regulation (derived from): MIIT [2009] No. 66 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the power vacuum with zirconium powder Determination of silicon content. This standard applies to electric vacuum zirconium powder Determination of silicon content. Measuring range (mass fraction): 0. 01% to 0. 15%. YS/T 574.3-2009: Methods for chemical analysis of zirconium powder for electro-vacuum uses. The molybdenum blue spectrophotometric method for determination of silicon---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of zirconium powder for electro-vacuum uses.The molybdenum blue spectrophotometric method for determination of silicon ICS 77.120 H71 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 574.3-2006 Electric vacuum Chemical analysis of zirconium powder Molybdenum blue spectrophotometric determination of silicon content Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 574 "Methods for chemical analysis of zirconium powder for electro - vacuum" is divided into eight sections. --- Determination of the total amount of zirconium and zirconium active YS/T 574.1 electric vacuum zirconium powder - Gravimetric method; --- YS/T 574.2 electric vacuum Chemical analysis of zirconium powder sulfosalicylic acid spectrophotometric determination of iron content; --- Determination of silicon content YS/T 574.3 electric vacuum chemical analysis of zirconium powder Molybdenum blue spectrophotometric method; --- YS/T 574.4 electric vacuum zirconium powder chemical analysis of molybdenum blue spectrophotometric determination of phosphorus content; Emission spectrometry measurement of calcium, magnesium content --- YS/T 574.5 electric vacuum zirconium powder chemical analysis by inductively coupled plasma; --- YS/T 574.6 electric vacuum zirconium powder chemical analysis of Chromium Azure S spectrophotometric determination of aluminum content; --- YS/T 574.7 electric vacuum Chemical analysis of zirconium powder with methylene blue spectrophotometric determination of sulfur content; Determination of the amount of hydrogen heating thermal conductivity method --- YS/T 574.8 electric vacuum Chemical analysis of zirconium powder with an inert atmosphere. This section YS/T 574 Part 3. The partial replacement of YS/T 574.3 "power vacuum spectrophotometric determination of zirconium powder with a chemical analysis of silicon molybdenum blue" (original GB/T 3256.3- 1982). This portion of YS/T 574.3-2006 compared to the main changes are as follows. --- Complements the precision and quality assurance and control provisions. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This in part by Western Metal Materials Co., Ltd., China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This part by CITIC Jinzhou Ferroalloy Co., Ltd., Northwest Nonferrous Metal Research Institute participated in the drafting. The main drafters of this section. Jiangyan Ni, Zhou Jinzhi, Ye Hongchuan, Bo. This part of the standard replaces the previous editions are. --- YS/T 574.3-2006. Electric vacuum Chemical analysis of zirconium powder Molybdenum blue spectrophotometric determination of silicon content1 ScopeThis section specifies the determination of the amount of silicon electric vacuum zirconium powder. This section applies to electric vacuum measuring silicon content of zirconium powder. Measurement range (mass fraction). 0.01% to 0.15%.2 principle of the methodThe sample is dissolved with hydrofluoric acid, boric acid masking fluoride ion. Silicic acid ammonium molybdate was added thereto to generate ions Si - Mo heteropoly acid was added grass Acid - sulfuric acid mixture to eliminate phosphorus, arsenic interference. Ferrous ammonium sulfate to restore the silicon molybdenum yellow silicon molybdenum blue, measured in a spectrophotometer at 700nm Absorbance.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical reagents and secondary deionized water. 3.1 boric acid, pure class distinctions. 3.2 pure zirconium, silicon content less than 0.002%. 3.3 hydrofluoric acid (commercially available 40%). pure class distinctions 3.4 sulfate (ρ1.84g/mL). 3.5 sulfate (1 + 4). 3.6 oxalic acid - sulfuric acid mixture. Weigh 25g of oxalic acid, placed in 500mL beaker, add water 200mL, 100mL sulfuric acid (3.4) to make it Dissolution, cooled to room temperature, diluted with water to 1000mL, and mix. 3.7 potassium permanganate solution (1g/L). 3.8 ammonium molybdate solution (50g/L). 3.9 ferrous ammonium sulfate solution (60g/L). Weigh 6g ferrous ammonium sulfate, placed in 200mL beaker, add 2mL of sulfuric acid (3.5), with Diluted with water to 100mL, stirred to dissolve, use (valid for 3 days) and filtered. 3.10 Silicon Storage standard solution. Weigh 0.2139g pre-burning 1h silica at 1000 ℃, placed in a platinum crucible, added 2g ~ 3g of anhydrous sodium carbonate, and mix. 900 ℃ high temperature furnace melting at 5min ~ 7min, then cool to room temperature. Placed in 400mL burn Cup, 200mL water was added and heated to dissolve the melt. Remove the crucible was washed with water, cooled to room temperature, transferred to 1000mL volumetric flask Diluted with water to volume, and mix. Immediately transferred to a polyethylene bottle save. This solution 1mL containing 100μg silicon. 3.11 Silicon standard solution. Pipette 100.00mL silicon standard stock solution (3.10) into 500mL volumetric flask, dilute to the mark, Mix well. Immediately transferred to a polyethylene bottle save. 1mL solution containing 20μg silicon.4 InstrumentSpectrophotometer.5 Experimental Procedure5.1 Sample Weigh 0.10g sample, accurate to 0.0001g. 5.2 blank test Along with sample blank test. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 574.3-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 574.3-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 574.3-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 574.3-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 574.3-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 574.3-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |