Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 562-2009 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 562-2009: Method for chemical analysis of precious metals alloys. Platinum-ruthenium alloys. Determination of ruthenium content. Thiourea spectrophotometry
Status: Valid

YS/T 562: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 562-2009169 Add to Cart 3 days Method for chemical analysis of precious metals alloys. Platinum-ruthenium alloys. Determination of ruthenium content. Thiourea spectrophotometry Valid
YS/T 562-2006199 Add to Cart 2 days Platinum- ruthenium alloy chemical analysis method Obsolete

Similar standards

GB/T 17472   GB/T 17473.2   GB/T 17473.1   YS/T 563   YS/T 564   YS/T 561   

Basic data

Standard ID: YS/T 562-2009 (YS/T562-2009)
Description (Translated English): Method for chemical analysis of precious metals alloys. Platinum-ruthenium alloys. Determination of ruthenium content. Thiourea spectrophotometry
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H68
Classification of International Standard: 77.120.99
Word Count Estimation: 6,636
Date of Issue: 2009-12-04
Date of Implementation: 2010-06-01
Older Standard (superseded by this standard): YS/T 562-2006
Quoted Standard: YS/T 371
Regulation (derived from): MIIT [2009] No. 66
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the platinum- ruthenium alloy method for determination of ruthenium. This standard applies to platinum- ruthenium alloy of ruthenium content. Measuring range: 5% to 10%.

YS/T 562-2009: Method for chemical analysis of precious metals alloys. Platinum-ruthenium alloys. Determination of ruthenium content. Thiourea spectrophotometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method for chemical analysis of precious metals alloys.Platinum-ruthenium alloys.Determination of ruthenium content.Thiourea spectrophotometry ICS 77.120.99 H68 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 562-2006 Precious metal alloys - Determination of the amount of ruthenium platinum ruthenium alloy Thiourea spectrophotometry Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

Instead of the standard YS/T 562-2006 "platinum-ruthenium alloy chemical analysis method for determining the amount of ruthenium." Compared with this standard YS/T 562-2006, the main changes are as follows. --- Standard name by the YS/T 562-2006 "platinum-ruthenium alloys - Determination of the amount of ruthenium" to "precious metal alloys stars Determination of analytical methods platinum ruthenium alloy ruthenium amount of thiourea spectrophotometry "; --- According to GB/T 20001.4-2001 format requirements rewritten. This standard by the National Standardization Technical Committee of non-ferrous metals and centralized. This standard was drafted. Your research Platinum Limited. The main drafters of this standard. Luo Yijiang possession Xiang, Gan Jian Zhuang. This standard replaces the standards previously issued as follows. --- GB/T 1486-1979; --- YS/T 562-2006. Precious metal alloys - Determination of the amount of ruthenium platinum ruthenium alloy Thiourea spectrophotometry

1 Scope

This standard specifies the method for determination of platinum-ruthenium alloy ruthenium content. This standard applies to the determination of platinum-ruthenium alloy ruthenium content. Measuring range. 5% to 10%.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. 371 precious metal alloys - General rules and regulations YS/T

3 PRINCIPLE OF THE METHOD

Sample was dissolved in a glass sealed tube chlorination. Hydrochloric acid - ethanol solution of ruthenium complexes with thiourea generate blue, determined by spectrophotometry.

4 Reagents and materials

Unless otherwise indicated, the reagents used in this standard and vessels shall comply with the provisions of YS/T 371's. 4.1 hydrochloride (ρ1.19g/mL). 4.2 HCl (1 + 1). Nitrate 4.3 (ρ1.42g/mL). 4.4 Hydrogen peroxide (30%). 4.5 Thiourea (100g/L), the day of preparation used. 4.6 hydrochloric acid - ethanol mixed solution. one volume of hydrochloric acid (4.1) with 1 volume of absolute ethanol. 4.7 hydrochloric acid - ethanol mixed solution. one volume of hydrochloric acid (4.2) with 1 volume of absolute ethanol. 4.8 ruthenium stock standard solution. Weigh 0.1250g powder metal ruthenium (Ru mass fraction of not less than 99.99%) were placed in a hard glass tube , Add 10mL of hydrochloric acid (4.1), 2mL hydrogen peroxide, after a sealed tube put steel casing, placed in an oven and heated at 150 ℃ ± 5 ℃ to End Totally dissolved. The solution was then transferred to the open pipe 250mL volumetric flask, add 25mL of hydrochloric acid (4.1), dilute to the mark and mix. This standard solution 1mL solution containing 0.500mg ruthenium. 4.9 Ruthenium standard solution. Pipette 50.00mL ruthenium stock standard solution in 250mL flask, add 20mL of hydrochloric acid (4.1), diluted with water Scale. Mix well. This standard solution containing 0.10mg per ml ruthenium. 4.10 platinum solution. Weigh 0.2500g platinum (platinum content not less than 99.99%) were placed in 300mL beaker, add 20mL hydrochloric acid (4.1), 8mL nitric acid (4.3), cover the surface of the pan, heated on a hot plate until completely dissolved. Cooled to room temperature, and dish washing surface Beibi. Heated on a hotplate to near dryness. Added 3mL hydrochloric acid (4.1), heated to near dryness, repeated three times. Wet salt dissolved in water, is added 10mL hydrochloric acid (4.1), and the solution was transferred to 100mL volumetric flask, dilute to the mark. Mix well. This standard solution containing 1mL 2.500mg platinum.

5 Instruments

UV-visible spectrophotometer.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 562-2009_English be delivered?

Answer: Upon your order, we will start to translate YS/T 562-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 562-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 562-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 562-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 562-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.